Publications by authors named "John Racadio"

Deep vein thrombosis is a major source of morbidity and mortality worldwide. Catheter-directed thrombolytics are the frontline approach for vessel recanalization, though fibrinolytic efficacy is limited for stiff, chronic thrombi. Although thrombin has been used in preclinical models to induce thrombosis, the effect on lytic susceptibility and clot stiffness is unknown.

View Article and Find Full Text PDF

Adjuvant ultrasound at 2 MHz with or without an ultrasound contrast agent improves the rate of thrombus resolution by recombinant tissue plasminogen activator (rt-PA) in laboratory and clinical studies. A sub-megahertz approach can further expand this therapy to a subset of patients with an insufficient temporal bone window, improving efficacy in unselected patient populations. The aim of this study was to determine if a clinical ultrasound contrast agent (UCA), Definity, and 220 kHz pulsed ultrasound accelerated rt-PA thrombolysis in a preclinical animal model of vascular occlusion.

View Article and Find Full Text PDF

Background: The safe and accurate placement of pedicle screws remains a critical step in open and minimally invasive spine surgery, emphasizing the need for intraoperative guidance techniques. Diffuse reflectance spectroscopy (DRS) is an optical sensing technology that may provide intraoperative guidance in pedicle screw placement.

Purpose: The study presents the first in vivo minimally invasive procedure using DRS sensing at the tip of a Jamshidi needle with an integrated optical K-wire.

View Article and Find Full Text PDF

Safe and accurate placement of pedicle screws remains a critical step in open and minimally invasive spine surgery. The diffuse reflectance spectroscopy (DRS) technique may offer the possibility of intra-operative guidance for pedicle screw placement. Currently, Magnetic Resonance Imaging (MRI) is one of the most accurate techniques used to measure fat concentration in tissues.

View Article and Find Full Text PDF

Objective: The goal of this study was to develop and validate a system for automatic segmentation of the spine, pedicle identification, and screw path suggestion for use with an intraoperative 3D surgical navigation system.

Methods: Cone-beam CT (CBCT) images of the spines of 21 cadavers were obtained. An automated model-based approach was used for segmentation.

View Article and Find Full Text PDF

Safe and accurate placement of screws remains a critical issue in open and minimally invasive spine surgery. We propose to use diffuse reflectance (DR) spectroscopy as a sensing technology at the tip of a surgical instrument to ensure a safe path of the instrument through the cancellous bone of the vertebrae. This approach could potentially reduce the rate of cortical bone breaches, thereby resulting in fewer neural and vascular injuries during spinal fusion surgery.

View Article and Find Full Text PDF

Introduction: Renal artery occlusive disease is poorly characterized in children; treatments include medications, endovascular techniques, and surgery. We aimed to describe the course of renovascular hypertension (RVH), its treatments and outcomes.

Methods: We performed literature review and retrospective review (1993-2014) of children with renovascular hypertension at our institution.

View Article and Find Full Text PDF

Background: Pulmonary nodules in pediatric oncology patients can present a diagnostic and treatment dilemma. Imaging findings are often nonspecific and tissue diagnosis may be required for appropriate treatment. The smaller subpleural nodules may not be visualized and cannot be palpated during video-assisted thoracoscopic surgical (VATS) resection.

View Article and Find Full Text PDF

Study Design: Cadaveric laboratory study.

Objective: To assess the feasibility and accuracy of minimally invasive thoracolumbar pedicle screw placement using augmented reality (AR) surgical navigation.

Summary Of Background Data: Minimally invasive spine (MIS) surgery has increasingly become the method of choice for a wide variety of spine pathologies.

View Article and Find Full Text PDF

HSV1716 is an oncolytic herpes simplex virus-1 (HSV-1) studied in adults via injection into the brain and superficial tumors. To determine the safety of administering HSV1716 to pediatric patients with cancer, we conducted a phase I trial of image-guided injection in young patients with relapsed or refractory extracranial cancers. We delivered a single dose of 10 to 10 infectious units of HSV1716 via computed tomography-guided intratumoral injection and measured tumor responses by imaging.

View Article and Find Full Text PDF

Study Design: A cadaveric laboratory study.

Objective: The aim of this study was to assess the feasibility and accuracy of thoracic pedicle screw placement using augmented reality surgical navigation (ARSN).

Summary Of Background Data: Recent advances in spinal navigation have shown improved accuracy in lumbosacral pedicle screw placement but limited benefits in the thoracic spine.

View Article and Find Full Text PDF

Background: Establishing postnatal nutrition delivery is challenging in neonates with immature sucking and swallowing ability. Enteral feeding is the gold standard for such patients, but their small size and fragility present challenges in nasogastric (NG) feeding tube placement. Feeding tubes are typically placed with x-ray guidance, which provides minimal soft tissue contrast and exposes the baby to ionizing radiation.

View Article and Find Full Text PDF

Background: Peripherally inserted central catheter (PICC) is among the most common procedures performed in children in the hospital setting. PICC insertion can be simplified with the use of a sheathed needle as an alternative to the modified Seldinger technique.

Objective: To retrospectively evaluate PICC placement for the technique used and the incidence of complications at a large pediatric tertiary care center.

View Article and Find Full Text PDF

Purpose To compare the navigational accuracy and radiation dose during needle localization of targets for augmented reality (AR) with and without motion compensation (MC) versus those for cone-beam computed tomography (CT) with real-time fluoroscopy navigation in a pig model. Materials and Methods This study was approved by the Institutional Animal Care and Use Committee. Three operators each localized 15 targets (bone fragments) approximately 7 cm deep in the paraspinal muscles of nine Yorkshire pigs by using each of the three modalities (AR with and without MC and cone-beam CT with fluoroscopy).

View Article and Find Full Text PDF

Purpose: To evaluate technical feasibility, complications, and clinical outcomes of endovascular thrombolysis for iliofemoral thrombosis at two tertiary-care children's hospitals.

Materials And Methods: Institutional review board-approved retrospective review from March 2003 through June 2013 showed that venous thrombolysis for iliofemoral thrombosis was performed in 57 children (64 limbs) with a median age of 16.1 years (mean age, 14.

View Article and Find Full Text PDF

Background: Sialorrhea is problematic for neurologically impaired children, and botulinum toxin A salivary gland injection has been reported as effective in reducing sialorrhea. This article assesses the success and safety of ultrasound-guided weight-based botulinum toxin A injection for the management of sialorrhea in children.

Methods: A total of 111 patients (63 males; 48 females; average age 7 years) with refractory sialorrhea were treated with ultrasound-guided botulinum toxin type A salivary gland injections (144 procedures) from July 1, 2004, to July 1, 2014, using a single weight-based protocol.

View Article and Find Full Text PDF

The purpose of this study was to reduce pediatric doses while maintaining or improv-ing image quality scores without removing the grid from X-ray beam. This study was approved by the Institutional Animal Care and Use Committee. Three piglets (5, 14, and 20 kg) were imaged using six different selectable detector air kerma (Kair) per frame values (100%, 70%, 50%, 35%, 25%, 17.

View Article and Find Full Text PDF

Background: Gaining access into non-dilated renal collecting systems for percutaneous nephrolithotripsy, particularly in patients with prohibitive body habitus and/or scoliosis, is often challenging using conventional techniques.

Objective: To evaluate the feasibility of cone-beam CT for percutaneous nephrostomy placement for subsequent percutaneous nephrolithotripsy in children and adolescents.

Materials And Methods: A retrospective review of percutaneous nephrostomy revealed use of cone-beam CT and 3-D guidance in 12 percutaneous nephrostomy procedures for 9 patients between 2006 and 2015.

View Article and Find Full Text PDF

Background: The authors previously described the generation of vascularized bone in a pig model, using a hemimandibular allograft scaffold, adipose-derived stem cells, recombinant human bone morphogenetic protein-2, and periosteum. This study tests the hypothesis that this "allograft revitalization" technique is as effective as vascularized autograft for repairing critical bony defects.

Methods: Three groups of pigs had 3-cm defects created in their bilateral tibial diaphyses for repair using rigid fixation and one of three modalities.

View Article and Find Full Text PDF

Posttransplant lymphoproliferative disorder (PTLD) is a well-described complication of solid organ and bone marrow transplants. The most common presentation is intra-abdominal lymphadenopathy or single or multiple intraparenchymal masses involving the liver, spleen, or kidneys. Here we describe the imaging and pathology findings of an unusual case of PTLD appearing as an intramuscular forearm lesion in a pediatric male.

View Article and Find Full Text PDF

Objective: The objective of our study was to survey radiation dose indexes of pediatric peripheral and abdominal fluoroscopically guided procedures from which estimates of diagnostic reference levels (DRLs) can be proposed for both a standard fluoroscope and a novel fluoroscope with advanced image processing and lower radiation dose rates.

Materials And Methods: Radiation dose structured reports were retrospectively collected for 408 clinical pediatric cases: Half of the procedures were performed with a standard imaging technology and half with a novel x-ray technology. Dose-area product (DAP), air Kerma (AK), fluoroscopy time, number of digital subtraction angiography images, and patient mass were collected to calculate and normalize radiation dose indexes for procedures completed with the standard and novel fluoroscopes.

View Article and Find Full Text PDF

Nine patients (average age 8.3 years, range 20 days to 17 years; average weight 31 kg, range 2.7-79 kg) with catheter-associated UE-DVT underwent upper extremity venous thrombolysis with the goal of access salvage.

View Article and Find Full Text PDF

Objective: This study presents the first in vivo real-time optical tissue characterization during image-guided percutaneous intervention using near-infrared diffuse optical spectroscopy sensing at the tip of a needle. The goal of this study was to indicate transition boundaries from healthy tissue to tumors, namely, hepatic carcinoma, based on the real-time feedback derived from the optical measurements.

Materials And Methods: Five woodchucks with hepatic carcinoma were used for this study.

View Article and Find Full Text PDF