Objective: To evaluate the 6-year clinical performance of Xeno IV, Xeno III, and XP Bond adhesives in the restoration of non-carious cervical lesions (NCCLs).
Methods: This was a randomized controlled clinical trial where 39 participants met the inclusion/exclusion criteria and were enrolled. Lesions restored were notch-shaped NCCLs.
Statement Of Problem: Composite resins are still outperformed by amalgams in the clinical practice with secondary caries and fractures being their most common failures. A material that suffers less polymerization shrinkage might improve the clinical performance of composite resins.
Purpose: To evaluate the clinical performance of a low-shrink silorane-based composite resin (Filtek LS Low Shrink Posterior Restorative, 3M ESPE, St.
Background: The authors conducted a study to evaluate the clinical performance of a dual-cured, three-step dentin adhesive (OptiBond Dual Cure, Kerr, a subsidiary of Sybron Dental Specialties, Orange, Calif.; no longer on the market) at 12 years.
Methods: The authors restored 100 noncarious cervical lesions without use of macromechanical retention or enamel bevels.
Background: The strategies for accomplishing resin adhesion to dentin involve surface conditioning, priming and bonding. One-bottle adhesives combine the priming and bonding functions in a single solution. In this study, the authors compared the eight-year clinical performance of two one-bottle adhesives made by different manufacturers.
View Article and Find Full Text PDFPurpose: To compare the clinical performance of a self-etching adhesive with that of a popular etch-and-rinse adhesive in Class I posterior composite restorations.
Methods: 60 Class I resin composite restorations (30 per group) were placed in matched pairs using either the self-etch adhesive Xeno III and the microhybrid resin composite Esthet-X or the etch-and-rinse adhesive OptiBond Solo Plus and Point 4 microhybrid resin composite. Subjects were interviewed via telephone 1 week after restoration placement to assess early post-operative sensitivity.
This randomized clinical trial compared the performance of an all-in-one adhesive (iBond) applied in sclerotic and non-sclerotic non-carious cervical lesions with that of a three-step etch-prime-bond adhesive (Gluma Solid Bond, SB). One-hundred and five lesions were randomly assigned to four groups according to adhesive, sclerosis scale and technique: 1) SB applied to lesions with sclerosis scale 1 and 2 (n=26); 2) iBond applied to lesions with sclerosis scale 1 and 2 (n=28); 3) iBond applied to lesions with sclerosis scale 3 and 4 (n=25) and 4) iBond applied with prior acid-etching to lesions with sclerosis scale 3 and 4 (n=26). A microfilled composite (Durafill VS) was used as the restorative material.
View Article and Find Full Text PDFAlthough posterior cusp fracture occurs frequently, its consequences are not well-delineated. This study recorded short-term outcomes (distribution of fractured teeth and cusps, fracture severity, and treatment received up to two years postfracture) for 517 fractured teeth from 498 subjects at a large group practice. Maxillary and mandibular tooth fractures occurred with similar frequency.
View Article and Find Full Text PDFStatement Of Problem: intact, prepared, and restored human maxillary premolars.
Material And Methods: Fifty intact, noncarious human maxillary premolars were divided into 5 groups of 10 and were mounted with their roots imbedded in autopolymerized acrylic. In the first group, the teeth were intact with no preparation.