Publications by authors named "John Orr"

Microscopy image analysis plays a crucial role in understanding cellular behavior and uncovering important insights in various biological and medical research domains. Tracking cells within the time-lapse microscopy images is a fundamental technique that enables the study of cell dynamics, interactions, and migration. While manual cell tracking is possible, it is time-consuming and prone to subjective biases that impact results.

View Article and Find Full Text PDF

Background & Aims: While physical inactivity can contribute to chronic diseases, regular activity like walking can help prevent them. In 2010, one in three adults in the U.S.

View Article and Find Full Text PDF

Shelter is one of the most 'intractable problems' in humanitarian aid and yet there is little clarity on an overarching definition. Terminology for shelter and housing is often conflated, and the most prominent definition does not fully reflect recent progress in the Shelter and Settlements Sector. This paper explores the varying terminology utilised in definitions of shelter within humanitarian aid since 1990, reflecting on the concepts of 'shelter' and 'housing', alongside surrounding perceptions of 'house' versus 'home', and related measures of adequacy.

View Article and Find Full Text PDF

Background: Physical inactivity is a public health concern in the US Virgin Islands (USVI). A contributing factor may be a lack of pedestrian infrastructure and other environmental supports for walking. In this manuscript, we describe the methods used to conduct a walkability audit of environmental features related to physical activity in the USVI.

View Article and Find Full Text PDF

Objectives: To determine the prevalence of community and street-scale design features that promote walking across the US Virgin Islands (USVI).

Methods: In May 2016, the USVI Department of Health, with technical assistance from the Centers for Disease Control and Prevention, conducted a territory-wide audit with a validated tool. We selected street segments (n = 1114) via a 2-stage sampling method, and estimates were weighted to be representative of publicly accessible street length.

View Article and Find Full Text PDF

Introduction: During total hip arthroplasty (THA), accurately predicting acetabular cup orientation remains a key challenge, in great part because of uncertainty about pelvic orientation. This pilot study aimed to develop and validate a technique to measure pelvic orientation; establish its accuracy in the location of anatomical landmarks and subsequently; investigate if limb movement during a simulated surgical procedure alters pelvic orientation.

Methods: The developed technique measured 3-D orientation of an isolated Sawbone pelvis, it was then implemented to measure pelvic orientation in lateral decubitus with post-THA patients (n = 20) using a motion capture system.

View Article and Find Full Text PDF

Ticks collected in 2011 were screened for the presence of filarial nematode genetic material, and positive samples were sequenced for analysis. Monanema-like filarial nematode DNA was recently discovered in Amblyomma americanum in northern Virginia, marking the first time genetic material from this parasite has been discovered in ticks in the state. Phylogenetic analysis revealed that this material was directly related to a previously discovered filarial nematode in A.

View Article and Find Full Text PDF

Perception of a leg length discrepancy post total hip arthroplasty (THA) is one of the most common sources of patient dissatisfaction and can have a direct influence on the considered success of the operation.This research examined postoperative perception of imposed limb discrepancies in a group of THA patients compared to a group of participants with no previous hip surgery. Two subgroups of THA patients were involved: those who did not perceive a difference in limb length following THA and those that did.

View Article and Find Full Text PDF

Currently there is no reliable objective method to quantify the setting properties of acrylic bone cements within an operating theatre environment. Ultrasonic technology can be used to determine the acoustic properties of the polymerising bone cement, which are linked to material properties and provide indications of the physical and chemical changes occurring within the cement. The focus of this study was the critical evaluation of pulse-echo ultrasonic test method in determining the setting and mechanical properties of three different acrylic bone cement when prepared under atmospheric and vacuum mixing conditions.

View Article and Find Full Text PDF

Spotted fever group rickettsiosis (SFGR) is a potentially fatal disease that has displayed increasing incidence in the United States in recent years. The most well-known and severe type of this disease is Rocky Mountain spotted fever, but there are other mild forms that occur. Recently, human infection with Rickettsia parkeri has been reported and linked with the tick Amblyomma maculatum.

View Article and Find Full Text PDF

The aim of the study was to use a computational and experimental approach to evaluate, compare and predict the ability of calcium phosphate (CaP) and poly (methyl methacrylate) (PMMA) augmentation cements to restore mechanical stability to traumatically fractured vertebrae, following a vertebroplasty procedure. Traumatic fractures (n = 17) were generated in a series of porcine vertebrae using a drop-weight method. The fractured vertebrae were imaged using μCT and tested under axial compression.

View Article and Find Full Text PDF

Restoration of joint centre during total hip arthroplasty is critical. While computer-aided navigation can improve accuracy during total hip arthroplasty, its expense makes it inaccessible to the majority of surgeons. This article evaluates the use, in the laboratory, of a calliper with a simple computer application to measure changes in femoral head centres during total hip arthroplasty.

View Article and Find Full Text PDF

The study aim was to develop and apply an experimental technique to determine the biomechanical effect of polymethylmethacrylate (PMMA) and calcium phosphate (CaP) cement on the stiffness and strength of augmented vertebrae following traumatic fracture. Twelve burst type fractures were generated in porcine three-vertebra segments. The specimens were randomly split into two groups (n=6), imaged using microCT and tested under axial loading.

View Article and Find Full Text PDF

The ability to measure acetabular cup orientation accurately during total hip arthroplasty represents a significant challenge. The aim of this research was to develop and evaluate a novel low cost mechanical device for measuring operative acetabular inclination. Cup implantation was simulated in two trials using the novel device: firstly involving surgeons and engineers orientating acetabular cups with sawbone pelves at a range of inclination angles (20°-55° in 5° increments); secondly in a simulated intra-operative scenario with surgeons.

View Article and Find Full Text PDF

Bioresorbable polymers have been widely investigated as materials exhibiting significant potential for successful application in the fields of tissue engineering and drug delivery. Further to the ability to control degradation, surface engineering of polymers has been highlighted as a key method central to their development. Previous work has demonstrated the ability of electron beam (e-beam) technology to control the degradation profiles and bioresorption of a number of commercially relevant bioresorbable polymers (poly-l-lactic acid (PLLA), L-lactide/DL-lactide co-polymer (PLDL) and poly(lactic-co-glycolic acid (PLGA)).

View Article and Find Full Text PDF

The aim of this study was to examine the potential of incorporating bovine fibres as a means of reinforcing a typically brittle apatite calcium phosphate cement for vertebroplasty. Type I collagen derived from bovine Achilles tendon was ground cryogenically to produce an average fibre length of 0.96±0.

View Article and Find Full Text PDF

Predicable and controlled degradation is not only central to the accurate delivery of bioactive agents and drugs, it also plays a vital role in key aspects of bone tissue engineering. The work addressed in this paper investigates the utilisation of e-beam irradiation in order to achieve a controlled (surface) degradation profile. This study focuses on the modification of commercially and clinically relevant materials, namely poly(L-lactic acid) (PLLA), poly(L-lactide-hydroxyapatite) (PLLA-HA), poly(L-lactide-glycolide) co-polymer (PLG) and poly(L-lactide-DL-lactide) co-polymer (PLDL).

View Article and Find Full Text PDF

Nine Souter-Strathclyde humeral and ulnar components retrieved from revision surgery for aseptic loosening were examined macro- and microscopically. The wear patterns were compared and photographed. Humeral components demonstrated no evidence of wear.

View Article and Find Full Text PDF

In this investigation Raman spectroscopy was shown to be a method that could be used to monitor the polymerisation of PMMA bone cement. Presently there is no objective method that orthopaedic surgeons can use to quantify the curing process of cement during surgery. Raman spectroscopy is a non-invasive, non-destructive technique that could offer such an option.

View Article and Find Full Text PDF

A successful total hip replacement has an expected service life of 10-20 years with over 75% of failures due to aseptic loosening which is directly related to cement mantle failure. The aim of the present study was to investigate the addition of nanoparticles of calcium carbonate to acrylic bone cement. It was anticipated that an improvement in mechanical performance of the resultant nanocomposite bone cement would be achieved.

View Article and Find Full Text PDF

The degradable polymers polylactide (PLA) and polylactide-co-glycolide (PLGA) have found widespread use in modern medical practice. However, their slow degradation rates and tendency to lose strength before mass have caused problems. The aim of this study was to ascertain whether treatment with e-beam radiation could address these problems.

View Article and Find Full Text PDF

A PHP Error was encountered

Severity: Warning

Message: fopen(/var/lib/php/sessions/ci_sessionjtloo5fk56mdcao2cr9076rvc283pm28): Failed to open stream: No space left on device

Filename: drivers/Session_files_driver.php

Line Number: 177

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_start(): Failed to read session data: user (path: /var/lib/php/sessions)

Filename: Session/Session.php

Line Number: 137

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once