Publications by authors named "John L. Robertson"

Raman spectroscopy (RS) is used increasingly for disease detection, including diseases of the nervous system (CNS). This Perspective presents RS basics and how it has been applied to disease detection. Research that focused on using a novel Raman-based technology-Rametrix Molecular Urinalysis (RMU)-for systemic disease detection is presented, demonstrated by an example of how the RS/RMU technology could be used for detection and management of diseases of the CNS in companion animals.

View Article and Find Full Text PDF

Introduction: The presence of cancer in dogs was detected by Raman spectroscopy of urine samples and chemometric analysis of spectroscopic data. The procedure created a multimolecular spectral fingerprint with hundreds of features related directly to the chemical composition of the urine specimen. These were then used to detect the broad presence of cancer in dog urine as well as the specific presence of lymphoma, urothelial carcinoma, osteosarcoma, and mast cell tumor.

View Article and Find Full Text PDF

Neurotropic oncolytic viruses are appealing agents to treat brain tumors as they penetrate the blood-brain barrier and induce preferential cytolysis of neoplastic cells. The pathobiological similarities between human and canine brain tumors make immunocompetent dogs with naturally occurring tumors attractive models for the study of oncolytic virotherapies. In this dose-escalation/expansion study, an engineered Lasota NDV strain targeting the urokinase plasminogen activator system (rLAS-uPA) was administered by repetitive intravenous infusions to 20 dogs with intracranial tumors with the objectives of characterizing toxicities, immunologic responses, and neuroradiological anti-tumor effects of the virus for up to 6 months following treatment.

View Article and Find Full Text PDF

Meningiomas are the most common feline primary brain tumours, and calvarial hyperostosis (CH) is frequently documented in association with this neoplastic entity. The clinical significance of and mechanisms driving the formation of CH in cats with meningiomas are poorly understood, although tumour invasion into the skull and tumour production of cytokines and enzymes have been implicated as causes of CH in humans. This retrospective study investigated relationships between signalment, MRI or CT imaging features, histopathologic tumour characteristics, alkaline phosphatase (ALP) isoenzyme concentrations, tumour expression of matrix metalloproteinases (MMP)-2, MMP-9, and interleukin-6 (IL-6), and progression free survival times (PFS) following surgical treatment in 27 cats with meningiomas with (n = 15) or without (n = 12) evidence of CH.

View Article and Find Full Text PDF

Background: In humans, the T2-weighted (T2W)-fluid-attenuated inversion recovery (FLAIR) mismatch sign (T2FMM) is a specific imaging biomarker for the isocitrate dehydrogenase 1 (IDH1)-mutated, 1p/19q non-codeleted low-grade astrocytomas (LGA). The T2FMM is characterized by a homogeneous hyperintense T2W signal and a hypointense signal with a hyperintense peripheral rim on FLAIR sequences. In gliomas in dogs, the T2FMM has not been described.

View Article and Find Full Text PDF

Background: Chronic kidney disease (CKD) poses a major public health burden. Diabetes mellitus (DM) is one of the major causes of CKD. In patients with DM, it can be difficult to differentiate diabetic kidney disease (DKD) from other causes of glomerular damage; it should not be assumed that all DM patients with decreased eGFR and/or proteinuria have DKD.

View Article and Find Full Text PDF

We developed and tested a method to detect COVID-19 disease, using urine specimens. The technology is based on Raman spectroscopy and computational analysis. It does not detect SARS-CoV-2 virus or viral components, but rather a urine 'molecular fingerprint', representing systemic metabolic, inflammatory, and immunologic reactions to infection.

View Article and Find Full Text PDF

Glioblastoma is the deadliest malignant brain tumor. Its location behind the blood-brain barrier (BBB) presents a therapeutic challenge by preventing effective delivery of most chemotherapeutics. H-FIRE is a novel tumor ablation method that transiently disrupts the BBB through currently unknown mechanisms.

View Article and Find Full Text PDF

Hematuria refers to the presence of blood in urine. Even in small amounts, it may be indicative of disease, ranging from urinary tract infection to cancer. Here, Raman spectroscopy was used to detect and quantify macro- and microhematuria in human urine samples.

View Article and Find Full Text PDF

A urine-based screening technique for Lyme disease (LD) was developed in this research. The screen is based on Raman spectroscopy, iterative smoothing-splines with root error adjustment (ISREA) spectral baselining, and chemometric analysis using Rametrix software. Raman spectra of urine from 30 patients with positive serologic tests (including the US Centers for Disease Control [CDC] two-tier standard) for LD were compared against subsets of our database of urine spectra from 235 healthy human volunteers, 362 end-stage kidney disease (ESKD) patients, and 17 patients with active or remissive bladder cancer (BCA).

View Article and Find Full Text PDF

The fiberoptic microneedle device (FMD) is a fused-silica microcatheter capable of co-delivery of fluids and light that has been developed for convection-enhanced delivery and photothermal treatments of glioblastoma. Here we investigate the biocompatibility of FMD fragments chronically implanted in the rat brain in the context of evaluating potential mechanical device failure. Fischer rats underwent craniectomy procedures for sham control (n = 16) or FMD implantation (n = 16) within the brain.

View Article and Find Full Text PDF

Bladder cancer (BCA) is relatively common and potentially recurrent/progressive disease. It is also costly to detect, treat, and control. Definitive diagnosis is made by examination of urine sediment, imaging, direct visualization (cystoscopy), and invasive biopsy of suspect bladder lesions.

View Article and Find Full Text PDF
Article Synopsis
  • The study focuses on the use of IL13RA2 and EPHA2 as therapeutic targets in gliomas, which are expressed in almost all canine and human cases but not in healthy brain tissue.
  • Researchers evaluated a new method of delivering IL-13 mutant and ephrin A1-based cytotoxins via convection-enhanced delivery (CED) to dogs with gliomas in a trial involving 17 dogs.
  • Results showed effective and safe delivery of the cytotoxins, with a notable tumor volume reduction in 50% of dogs treated, indicating potential for translating this approach to human glioma treatments.
View Article and Find Full Text PDF
Article Synopsis
  • The Rametrix PRO Toolbox v1.0 for MATLAB enhances the existing Rametrix LITE Toolbox by offering advanced evaluation of chemometric models, specifically for predictive capabilities when dealing with unknown samples.
  • This toolbox conducts leave-one-out analysis and provides metrics like accuracy, sensitivity, and specificity, helping to assess the performance of classification models in vibrational spectroscopy data.
  • In a study on chronic kidney disease detection using urine Raman spectra, the optimal use of principal components in the model resulted in perfect classification performance, highlighting the effectiveness of Rametrix PRO in refining model evaluation.
View Article and Find Full Text PDF

Raman Chemometric Urinalysis (RametrixTM) was used to discern differences in Raman spectra from (i) 362 urine specimens from patients receiving peritoneal dialysis (PD) therapy for end-stage kidney disease (ESKD), (ii) 395 spent dialysate specimens from those PD therapies, and (iii) 235 urine specimens from healthy human volunteers. RametrixTM analysis includes spectral processing (e.g.

View Article and Find Full Text PDF

Treatment of intracranial disorders suffers from the inability to accumulate therapeutic drug concentrations due to protection from the blood-brain barrier (BBB). Electroporation-based therapies have demonstrated the capability of permeating the BBB, but knowledge of the longevity of BBB disruption (BBBD) is limited. In this study, we quantify the temporal, high-frequency electroporation (HFE)-mediated BBBD in an in vivo healthy rat brain model.

View Article and Find Full Text PDF

Raman chemometric urinalysis (Rametrix™) was used to analyze 235 urine specimens from healthy individuals. The purpose of this study was to establish the "range of normal" for Raman spectra of urine specimens from healthy individuals. Ultimately, spectra falling outside of this range will be correlated with kidney and urinary tract disease.

View Article and Find Full Text PDF

This study evaluates the effects of various pulsing paradigms, on the irreversible electroporation (IRE) lesion, induced electric current, and temperature changes using a perfused porcine liver model. A 4-monopolar electrode array delivered IRE therapy varying the pulse length and inter-pulse delay to six porcine mechanically perfused livers. Pulse paradigms included six forms of cycled pulsing schemes and the conventional pulsing scheme.

View Article and Find Full Text PDF

Irreversible electroporation is a proven ablation modality for local ablation of soft tissue tumors in animals and humans. However, the strong muscle contractions associated with the electrical impulses (duration, 50-100 μs) requires the use of general anesthesia and, in most situations, application of neuromuscular blockade. As such, this technology is not used in an outpatient setting for ablating common cutaneous tumors (e.

View Article and Find Full Text PDF
Article Synopsis
  • Stereotactic brain biopsy (SBB) is a method used to accurately diagnose brain tumors in dogs, showing a high diagnostic accuracy with 81% concordance in the study.
  • A study of 31 dogs revealed strong agreement between SBB findings and reference diagnoses, especially for tumors like meningiomas, but noted challenges in grading gliomas.
  • To enhance diagnostic reliability, it's recommended to collect multiple SBB specimens, especially for smaller tumors, as this can lead to improved agreement and better inform treatment options.
View Article and Find Full Text PDF

Purpose: This study evaluates the effects of active electrode cooling, via internal fluid circulation, on the irreversible electroporation (IRE) lesion, deployed electric current and temperature changes using a perfused porcine liver model.

Materials And Methods: A bipolar electrode delivered IRE electric pulses with or without activation of internal cooling to nine porcine mechanically perfused livers. Pulse schemes included a constant voltage, and a preconditioned delivery combined with an arc-mitigation algorithm.

View Article and Find Full Text PDF

The ability to interface microfluidic devices with native complex biological architectures, such as whole organs, has the potential to shift the paradigm for the study and analysis of biological tissue. Here, we show 3D printing can be used to fabricate bio-inspired conformal microfluidic devices that directly interface with the surface of whole organs. Structured-light scanning techniques enabled the 3D topographical matching of microfluidic device geometry to porcine kidney anatomy.

View Article and Find Full Text PDF

Background: The expression of the urokinase plasminogen activator receptor (uPAR), a glycosylphosphatidylinositol-anchored protein family member, and the activity of its ligand, urokinase-type plasminogen activator (uPA), have been associated with the invasive and metastatic potentials of a variety of human brain tumors through their regulation of extracellular matrix degradation. Domesticated dogs develop naturally occurring brain tumors that share many clinical, phenotypic, molecular, and genetic features with their human counterparts, which has prompted the use of the dogs with spontaneous brain tumors as models to expedite the translation of novel brain tumor therapeutics to humans. There is currently little known regarding the role of the uPA system in canine brain tumorigenesis.

View Article and Find Full Text PDF

A new thin-filmed perfusion sensor was developed using a heat flux gauge, thin-film thermocouple, and a heating element. This sensor, termed "CHFT+," is an enhancement of the previously established combined heat flux-temperature (CHFT) sensor technology predominately used to quantify the severity of burns [1]. The CHFT+ sensor was uniquely designed to measure tissue perfusion on explanted organs destined for transplantation, but could be functionalized and used in a wide variety of other biomedical applications.

View Article and Find Full Text PDF

The mixed-metal supramolecular complex, [(Phphen)Ru(dpp)PtCl], displays significant DNA modification, cell growth inhibition, and toxicity towards F98 malignant glioma cells following visible light irradiation. The design of this complex affords superior cellular uptake and antiproliferative activity compared to the classic chemotherapeutic agent, cisplatin.

View Article and Find Full Text PDF