This research introduces BAE-ViT, a specialized vision transformer model developed for bone age estimation (BAE). This model is designed to efficiently merge image and sex data, a capability not present in traditional convolutional neural networks (CNNs). BAE-ViT employs a novel data fusion method to facilitate detailed interactions between visual and non-visual data by tokenizing non-visual information and concatenating all tokens (visual or non-visual) as the input to the model.
View Article and Find Full Text PDFPurpose: The critical time between stroke onset and treatment was targeted for reduction by integrating physiological imaging into the angiography suite, potentially improving clinical outcomes. The evaluation was conducted to compare C-Arm cone beam CT perfusion (CBCTP) with multi-detector CT perfusion (MDCTP) in patients with acute ischemic stroke (AIS).
Approach: Thirty-nine patients with anterior circulation AIS underwent both MDCTP and CBCTP.
Diabetes mellitus and metabolic syndrome are closely linked with visceral body composition, but clinical assessment is limited to external measurements and laboratory values including hemoglobin A1c (HbA1c). Modern deep learning and AI algorithms allow automated extraction of biomarkers for organ size, density, and body composition from routine computed tomography (CT) exams. Comparing visceral CT biomarkers across groups with differing glycemic control revealed significant, progressive CT biomarker changes with increasing HbA1c.
View Article and Find Full Text PDFThe long-acting glucagon-like peptide-1 receptor agonist semaglutide is used to treat type 2 diabetes or obesity in adults. Clinical trials have observed associations of semaglutide with weight loss, improved control of diabetes, and cardiovascular risk reduction. The purpose of this study was to evaluate intrapatient changes in body composition after initiation of semaglutide therapy by applying an automated suite of CT-based artificial intelligence (AI) body composition tools.
View Article and Find Full Text PDFBiomed Phys Eng Express
August 2024
Investigating U-Net model robustness in medical image synthesis against adversarial perturbations, this study introduces RobMedNAS, a neural architecture search strategy for identifying resilient U-Net configurations. Through retrospective analysis of synthesized CT from MRI data, employing Dice coefficient and mean absolute error metrics across critical anatomical areas, the study evaluates traditional U-Net models and RobMedNAS-optimized models under adversarial attacks. Findings demonstrate RobMedNAS's efficacy in enhancing U-Net resilience without compromising on accuracy, proposing a novel pathway for robust medical image processing.
View Article and Find Full Text PDFObjectives: To evaluate the utility of CT-based abdominal fat measures for predicting the risk of death and cardiometabolic disease in an asymptomatic adult screening population.
Methods: Fully automated AI tools quantifying abdominal adipose tissue (L3 level visceral [VAT] and subcutaneous [SAT] fat area, visceral-to-subcutaneous fat ratio [VSR], VAT attenuation), muscle attenuation (L3 level), and liver attenuation were applied to non-contrast CT scans in asymptomatic adults undergoing CT colonography (CTC). Longitudinal follow-up documented subsequent deaths, cardiovascular events, and diabetes.
Objective: To assess the diagnostic performance of post-contrast CT for predicting moderate hepatic steatosis in an older adult cohort undergoing a uniform CT protocol, utilizing hepatic and splenic attenuation values.
Materials And Methods: A total of 1676 adults (mean age, 68.4 ± 10.
Objective: Fully-automated CT-based algorithms for quantifying numerous biomarkers have been validated for unenhanced abdominal scans. There is great interest in optimizing the documentation and reporting of biophysical measures present on all CT scans for the purposes of opportunistic screening and risk profiling. The purpose of this study was to determine and adjust the effect of intravenous (IV) contrast on these automated body composition measures at routine portal venous phase post-contrast imaging.
View Article and Find Full Text PDFBackground: In the prehospital tranexamic acid (TXA) for traumatic brain injury (TBI) trial, TXA administered within 2 hours of injury in the out-of-hospital setting did not reduce mortality in all patients with moderate/severe traumatic brain injury (TBI). We examined the association between TXA dosing arms, neurologic outcome, and mortality in patients with intracranial hemorrhage (ICH) on computed tomography (CT).
Methods: This was a secondary analysis of the Prehospital Tranexamic Acid for TBI Trial ( ClinicalTrials.
Large language models (LLMs) have shown promise in accelerating radiology reporting by summarizing clinical findings into impressions. However, automatic impression generation for whole-body PET reports presents unique challenges and has received little attention. Our study aimed to evaluate whether LLMs can create clinically useful impressions for PET reporting.
View Article and Find Full Text PDFPurpose: To compare fully automated artificial intelligence body composition measures derived from thin (1.25 mm) and thick (5 mm) slice abdominal CT data.
Methods: In this retrospective study, fully automated CT-based body composition algorithms for quantifying bone attenuation, muscle attenuation, muscle area, liver attenuation, liver volume, spleen volume, visceral-to-subcutaneous fat ratio (VSR) and aortic calcium were applied to both thin (1.
Purpose: To determine if fine-tuned large language models (LLMs) can generate accurate, personalized impressions for whole-body PET reports.
Materials And Methods: Twelve language models were trained on a corpus of PET reports using the teacher-forcing algorithm, with the report findings as input and the clinical impressions as reference. An extra input token encodes the reading physician's identity, allowing models to learn physician-specific reporting styles.
Purpose: To assess the ability of an automated AI tool to detect intravenous contrast material (IVCM) in abdominal CT examinations using spleen attenuation.
Methods: A previously validated automated AI tool measuring the attenuation of the spleen was deployed on a sample of 32,994 adult (age ≥ 18) patients (mean age, 61.9 ± 14.
Deep learning faces a significant challenge wherein the trained models often underperform when used with external test data sets. This issue has been attributed to spurious correlations between irrelevant features in the input data and corresponding labels. This study uses the classification of COVID-19 from chest x-ray radiographs as an example to demonstrate that the image contrast and sharpness, which are characteristics of a chest radiograph dependent on data acquisition systems and imaging parameters, can be intrinsic shortcuts that impair the model's generalizability.
View Article and Find Full Text PDFDeep learning (DL) models can harness electronic health records (EHRs) to predict diseases and extract radiologic findings for diagnosis. With ambulatory chest radiographs (CXRs) frequently ordered, we investigated detecting type 2 diabetes (T2D) by combining radiographic and EHR data using a DL model. Our model, developed from 271,065 CXRs and 160,244 patients, was tested on a prospective dataset of 9,943 CXRs.
View Article and Find Full Text PDFSplenomegaly historically has been assessed on imaging by use of potentially inaccurate linear measurements. Prior work tested a deep learning artificial intelligence (AI) tool that automatically segments the spleen to determine splenic volume. The purpose of this study is to apply the deep learning AI tool in a large screening population to establish volume-based splenomegaly thresholds.
View Article and Find Full Text PDFRadiologic tests often contain rich imaging data not relevant to the clinical indication. Opportunistic screening refers to the practice of systematically leveraging these incidental imaging findings. Although opportunistic screening can apply to imaging modalities such as conventional radiography, US, and MRI, most attention to date has focused on body CT by using artificial intelligence (AI)-assisted methods.
View Article and Find Full Text PDFDeep learning faces a significant challenge wherein the trained models often underperform when used with external test data sets. This issue has been attributed to spurious correlations between irrelevant features in the input data and corresponding labels. This study uses the classification of COVID-19 from chest x-ray radiographs as an example to demonstrate that the image contrast and sharpness, which are characteristics of a chest radiograph dependent on data acquisition systems and imaging parameters, can be intrinsic shortcuts that impair the model's generalizability.
View Article and Find Full Text PDF