Bull Hosp Jt Dis (2013)
November 2016
Background: The incidence of distal femoral periprosthetic fractures associated with total knee arthroplasty (TKA) has been reported as 0.3% to 2.5%.
View Article and Find Full Text PDFPurpose: The purpose of this study was to evaluate preoperative transthoracic echocardiography (TTE) on cardiac intervention, length of stay (LOS), inpatient mortality, and costs.
Methods: A retrospective series of 43 preoperative TTE and 161 non-TTE (control) hip fracture patients (> 65 years) was reviewed. The data collected included ASA score, comorbidities, indication for TTE, perioperative cardiac intervention, LOS, inpatient mortality, and cost.
Background: Polyethylene liner dissociation is a rare but catastrophic event in total hip arthroplasty (THA), and certain implant designs are known to be at greater risk. Although the DePuy Pinnacle (Warsaw, IN, USA) modular acetabular construct has an excellent record of fixation and wear, an unexpectedly high number of liner dissociations has been noted.
Questions/purposes: The purposes of this study were (1) to characterize the clinical parameters observed in a large group of patients who have experienced liner dissociations with the DePuy Pinnacle acetabular component; (2) to describe the radiographic findings in this group of patients; and (3) to calculate a minimum frequency of this complication.
Patients with diabetes have a higher incidence of infection after total joint arthroplasty (TJA) than patients without diabetes. Hemoglobin A1c (HbA1c) levels are a marker for blood glucose control in diabetic patients. A total of 3468 patients underwent 4241 primary or revision total hip arthroplasty or total knee arthroplasty at one institution.
View Article and Find Full Text PDFThe purpose of this study was to compare initial stability and late migration of 775 cementless acetabular components with and without screw fixation. Screw fixation was used in 509 cups and no screws in 266 cups. Average follow-up in the screw fixation group was 6.
View Article and Find Full Text PDFThe purpose of this article was to demonstrate the efficacy of a cementless, flat, tapered wedge femoral stem and compare cobalt-chrome and titanium femoral stems with this design. Three hundred ninety femoral stems observed for a mean of 4.7 years (2.
View Article and Find Full Text PDFThe purposes of this study were to compare the accuracy of acetate and digital templating for primary total hip arthroplasty (THA) and to determine if digital templating is safe. Preoperative planning was performed on 50 consecutive preoperative radiographs during 2005. Templating results were compared with the actual hip implants used.
View Article and Find Full Text PDFClin Orthop Relat Res
November 2007
Unlabelled: Accurate preoperative templating can facilitate precise, efficient, and reproducible total knee arthroplasty. We determined whether acetate templating accurately predicted knee implants used and compared the accuracy of digital templating. Preoperative planning was performed on 50 consecutive preoperative radiographs during 2005.
View Article and Find Full Text PDFDislocation rates after posterior approach THA have decreased with the advent of enhanced posterior soft tissue (EPSTR) repairs that incorporate the external rotators. We examined three posterior approaches (simple posterior repair, EPSTR, and posterior minimal incision surgery using enhanced posterior soft tissue repair) performed by one surgeon in 390 consecutive primary THA operations (390 patients) from 1992-2003. A simple posterior repair of the external rotators done through three drill holes was performed in the first 90 patients.
View Article and Find Full Text PDF