Introduction: Medial epicondyle fracture displacement is notoriously difficult to determine on conventional radiography, and follow-up computed tomography (CT) is often obtained to measure precise displacement. Another option for fracture characterization is digital tomosynthesis (DT), a technology providing high in-plane resolution of bony anatomy by acquiring multiple low-dose images in a linear arc. Advantages of DT include lower radiation exposure and lower cost than CT, rapid image acquisition, and a similar patient experience to conventional radiography.
View Article and Find Full Text PDFMucopolysaccharidosis type VII (MPS7) is a lysosomal storage disorder (LSD) resulting from mutations in the β-glucuronidase gene, leading to multiorgan dysfunction and fetal demise. While postnatal enzyme replacement therapy (ERT) and hematopoietic stem cell transplantation have resulted in some phenotypic improvements, prenatal treatment might take advantage of a unique developmental window to penetrate the blood-brain barrier or induce tolerance to the missing protein, addressing two important shortcomings of postnatal therapy for multiple LSDs. We performed in utero ERT (IUERT) at E14.
View Article and Find Full Text PDFBackground: Pediatric elbow fractures are common but remain challenging to accurately diagnose. Digital tomosynthesis is a technique that has shown promise in difficult adult fracture patterns but has not been formally studied in the pediatric population.
Objective: To assess the added value of digital tomosynthesis on the detection and diagnostic confidence of pediatric elbow fractures.
Imaging pediatric elbow trauma in the acute setting remains diagnostically challenging given difficult patient positioning, multiple ossification centers of the pediatric elbow, overlapping structures, and complex joint anatomy. Digital tomosynthesis is a technique where the X-ray source travels across a limited arc angle, obtaining a series of low-dose exposures that are in turn digitally reconstructed to produce high in-plane resolution at a relatively low overall radiation dose. Digital tomosynthesis is now more commonly integrated into standard radiographic machines and offers a new and exciting way to assess the pediatric elbow.
View Article and Find Full Text PDFA new approach to stable, low resistance inexpensive printed flexible conductive inks is proposed. Silver inks have been extensively studied and commercialized for applications in printed electronics due to the inherent high conductivity and stability of silver, even in particulate-based percolation networks processed at temperatures compatible with low-cost polymer films such as poly(ethylene terephthalate) (PET). Recent interest in flexible and even stretchable circuits, however, has presented new challenges for particle-based inks as mechanical strains can result in the opening of critical particle-to-particle contacts.
View Article and Find Full Text PDFBackground: Optimized MRI parameters can be leveraged to improve signal intensity, accelerate imaging acquisition and increase resolution. Higher-resolution imaging with a small field of view (FOV) has been proposed as standard practice for investigating sacroiliac (SI) joints, but the improvement in disease detection and characterization over pelvic imaging with large FOV has not been established.
Objective: The purpose of this study was to compare dedicated MR images of the SI joints with survey imaging (large-FOV pelvic MRI) for detecting sacroiliitis.
The detection and treatment monitoring of inflammatory states remain challenging in part due to the multifactorial mechanisms of immune activation and spectrum of clinical manifestations. Currently, diagnostic strategies tend to be subjective and limited quantitative tools exist to monitor optimal treatment strategies. Pro-inflammatory M1 polarized macrophages exhibit a distinct metabolic glycolytic phenotype compared to the continuum of M2 polarization states.
View Article and Find Full Text PDFIntussusception is a common etiology of acute abdominal pain in children. Over the last 70 years, there have been significant changes in how we diagnose and treat intussusception, with a more recent focus on the role of ultrasound. In this article we discuss historical and current approaches to intussusception, with an emphasis on ultrasound as a diagnostic and therapeutic modality.
View Article and Find Full Text PDFThe purpose of this study was to compare IVIM values in pediatric renal transplants with histopathology and clinical management change. Fifteen pediatric renal transplant recipients (mean 15.7±2.
View Article and Find Full Text PDFThis review provides a comprehensive and practical approach to pediatric percutaneous renal transplant biopsies, highlighting techniques and strategies to optimize adequate sample yield and ensure patient safety. In children with end-stage renal disease, transplantation is the preferred choice of therapy, providing for overall lower long-term morbidity and mortality compared with dialysis. In the ongoing management of renal transplant patients, core tissue sampling via a percutaneous renal biopsy remains the gold standard when transplant dysfunction is suspected.
View Article and Find Full Text PDFObjective: Fractional anisotropy (FA) is a measure of molecular motion obtained from diffusion tensor imaging (DTI). The objective of this study was to assess the use of FA as a noninvasive correlate of renal allograft histopathology.
Subjects And Methods: Sixteen pediatric renal allograft recipients were imaged using DTI in a prospective study, between October 2014 and January 2016, before a same-day renal allograft biopsy.
Purpose: Computed tomography (CT) use in emergency departments represents a significant contribution to pediatric patients' exposure to ionizing radiation. Here, we evaluate whether ultralow-dose chest CT can be diagnostically adequate for other diagnoses and whether model-based iterative reconstruction (MBIR) can improve diagnostic adequacy compared to adaptive statistical iterative reconstruction (ASIR) at ultralow doses.
Methods: Twenty children underwent chest CTs: 10 standard-dose reconstructed with ASIR and 10 ultralow-dose reconstructed with ASIR and MBIR.
Rationale And Objectives: Abdominal magnetic resonance angiography (MRA) has gained favor in pediatric patients owing to its lack of ionizing radiation and noninvasive nature. Reports exist regarding incidental findings on body MRA in adult patients. However, the incidental findings in pediatric abdominal MRA have not been previously reported.
View Article and Find Full Text PDFObjective: The objective was to identify a shear wave speed (SWS) cutoff in pediatric liver disease to detect fibrosis and inflammation.
Methods: We performed an institutional-review-board-approved prospective study of liver SWS in 41 children undergoing liver biopsy.
Results: In patients without inflammation, SWS was higher when fibrosis was present compared to when fibrosis was not present (average SWS 1.
Purpose: To evaluate the fused, colorized diffusion weighted imaging (DWI) and anatomic T2 images compared to routine contrast-enhanced T1 images at pediatric magnetic resonance enterography (MRE).
Methods: Fused, colorized DWI/T2 images were created from patients with magnetic resonance enterography (MRE) and colonoscopy/biopsy. Radiologists noted inflammation in five bowel segments (terminal ileum-rectosigmoid colon) on postcontrast images and DWI/T2 images.
BMC Med Inform Decis Mak
July 2016
Background: Glands are vital structures found throughout the human body and their structure and function are affected by many diseases. The ability to segment and detect glands among other types of tissues is important for the study of normal and disease processes and helps their analysis and visualization by pathologists in microscopic detail.
Methods: In this paper, we develop a new approach for segmenting and detecting intestinal glands in H&E-stained histology images, which utilizes a set of advanced image processing techniques: graph search, ensemble, feature extraction, and classification.
Retinoid therapy has contributed to improved outcomes in neuroblastoma. Clinical trials of fenretinide report favorable toxicity and disease stabilization in patients with high risk (HR) neuroblastoma. Skeletal effects have been described with other retinoids, but not with fenretinide to date.
View Article and Find Full Text PDFBackground: Fluoroscopy technologists routinely place a lead shield between the x-ray table and the patient's gonads, even if the gonads are not directly in the x-ray field. Internal scatter radiation is the greatest source of radiation to out-of-field body parts, but a shield placed between the patient and the x-ray source will not block internal scatter. Prior nonfluoroscopy research has shown that there is a small reduction in radiation dose when shielding the leakage radiation that penetrates through the collimator shutters.
View Article and Find Full Text PDFMüllerian duct anomalies encompass a wide variety of disorders resulting from abnormalities in the embryological development of the Müllerian ducts. In the prepubertal pediatric population, Müllerian duct anomalies are often incidental findings on studies obtained for other reasons. The onset of menses can prompt more clinical symptoms.
View Article and Find Full Text PDFObjective: To optimise image quality and reduce radiation exposure for infant body CT imaging.
Methods: An image quality CT phantom was created to model the infant body habitus. Image noise, spatial resolution, low contrast detectability and tube current modulation (TCM) were measured after adjusting CT protocol parameters.
J Pediatr Gastroenterol Nutr
July 2016
Objectives: The aim of the present study was to demonstrate the effectiveness and cost savings of a nonanesthesia approach to magnetic resonance enterography (MRE) in 14 young pediatric patients (age 4-7 years) with clinically suspected early-onset inflammatory bowel disease using an MRE protocol.
Methods: MRE was performed using a combination of an abbreviated imaging protocol, magnetic resonance imaging video goggles, and Child Life Services support. MRE results were correlated with both colonoscopy and pathology results using Pearson correlation coefficient.
Discovery of scrotal swelling in a neonate can be a source of anxiety for parents, clinicians, and sonologists alike. This pictorial essay provides a focused review of commonly encountered scrotal masses and mimics specific to the neonatal setting. Although malignancy is a concern, it is very uncommon, as most neonatal scrotal masses are benign.
View Article and Find Full Text PDFObjective: Biomedical imaging research relies heavily on the subjective and semi-quantitative reader analysis of images. Current methods are limited by interreader variability and fixed upper and lower limits. The purpose of this study was to compare the performance of two assessment methods, pairwise comparison and Likert scale, for improved analysis of biomedical images.
View Article and Find Full Text PDFMed Image Comput Comput Assist Interv
November 2014
Identifying neutrophils lays a crucial foundation for diagnosing acute inflammation diseases. But, such computerized methods on the commonly used H&E staining histology tissue images are lacking, due to various inherent difficulties of identifying cells in such image modality and the challenge that a considerable portion of neutrophils do not have a "textbook" appearance. In this paper, we propose a new method for identifying neutrophils in H&E staining histology tissue images.
View Article and Find Full Text PDF