Background/objectives: This study aimed to investigate pneumothorax risk, focusing on the gravitational effect of pleural pressure caused by specific patient positioning.
Methods: We retrospectively analyzed 144 percutaneous CT-guided lung biopsies performed between January 2019 and December 2023. Patients were grouped into those with or without pneumothorax.
Background/objectives: This study was conducted to compare two modes of computed tomography fluoroscopy (CTF) and two gastropexy techniques used in CT-guided percutaneous radiologic gastrostomy (CT-PRG) aiming to identify the optimal techniques for image guidance and gastropexy and, thus, to overcome the current lack of consensus on the preferred modalities.
Methods: We retrospectively identified 186 successful CT-PRG procedures conducted evenly across two university hospitals from January 2019 to December 2023. Patients were divided into two groups (intermittent multislice CT biopsy mode-guided technique (MS-CT BM) and retention anchor suture (T-fastener) versus real-time (RT-)CTF and gastropexy device) for descriptive analysis of demographics, indication for PRG, radiation exposure (DLP), procedural time, number of CT scans, gastropexy time, and complications.
Sci Rep
September 2024
The study aimed to evaluate the impact of AI assistance on pulmonary nodule detection rates among radiology residents and senior radiologists, along with assessing the effectiveness of two different commercialy available AI software systems in improving detection rates and LungRADS classification in chest CT. The study cohort included 198 participants with 221 pulmonary nodules. Residents' mean detection rate increased significantly from 64 to 77% with AI assist, while seniors' detection rate remained largely unchanged (85% vs.
View Article and Find Full Text PDFDiagnostics (Basel)
August 2024
Background: This study investigated and compared the efficacy, safety, radiation exposure, and financial compensation of two modalities for percutaneous radiologic gastrostomy (PRG): multislice computed tomography biopsy mode (MS-CT BM)-guided and fluoroscopy-guided (FPRG). The aim was to provide insights into optimizing radiologically assisted gastrostomy procedures.
Methods: We conducted a retrospective analysis of PRG procedures performed at a single center from January 2018 to January 2024.
To determine the diagnostic performance of simulated reduced-dose chest CT scans regarding pulmonary T1 tumors and assess the potential impact on patient management, a repository of 218 patients with histologically proven pulmonary T1 tumors was used. Virtual reduced-dose images were simulated at 25%- and 5%-dose levels. Tumor size, attenuation, and localization were scored by two experienced chest radiologists.
View Article and Find Full Text PDFPurpose: This study investigated strategies to reduce pneumothorax risk in CT-guided lung biopsy. The approach involved administering 10 ml of 1 % lidocaine fluid in the subpleural or pleural space before lung puncture and utilizing the gravitational effect of pleural pressure with specific patient positioning.
Method: We retrospectively analyzed 72 percutaneous CT-guided lung biopsies performed at a single center between January 2020 and April 2023.
Background: Extracellular volume (ECV) correlates with the degree of liver fibrosis.
Purpose: To analyze the performance of liver MRI-based ECV evaluations with different blood pool measurements at different time points.
Study Type: Prospective.
Objectives: Administration of gadolinium-based contrast agents (GBCA) in magnetic resonance imaging results in the long-term retention of gadolinium (Gd) in tissues and organs, including the bone, and may affect their function and metabolism. This study aims to investigate the effects of Gd and GBCA on the proliferation/survival, differentiation, and function of bone cell lineages.
Materials And Methods: Primary murine osteoblasts (OB) and osteoclast progenitor cells (OPC) isolated from C57BL/6J mice were used to test the effects of Gd 3+ (12.
Gallstone ileus is a well-known cause of small bowel obstruction in the radiological literature. In the experience of these authors, gallstone ileus occurs more often in quiz cases for registrars than in the everyday casework of a radiologist. The here presented case of a gallstone ileus provides a good opportunity to summarize cause, clinical presentation, radiological findings, and treatment options for both those studying for the specialist examinations and those whose specialist examinations are long past.
View Article and Find Full Text PDFObjectives: The purpose of this study was to determine the influence of dose reduction on a commercially available lung cancer prediction convolutional neuronal network (LCP-CNN).
Methods: CT scans from a cohort provided by the local lung cancer center (n = 218) with confirmed pulmonary malignancies and their corresponding reduced dose simulations (25% and 5% dose) were subjected to the LCP-CNN. The resulting LCP scores (scale 1-10, increasing malignancy risk) and the proportion of correctly classified nodules were compared.
Next-generation gadolinium-based contrast agents (GBCAs), including both high relaxivity agents and targeted agents, and manganese-based agents with a high probably of commercial success are discussed in some depth. It is highly likely that gadopiclenol and gadoquatrane, both next-generation high relaxivity gadolinium-based compounds, will come in time to replace the current macrocyclic gadolinium chelates, despite the wide acceptance, very high safety profile, and high stability of the latter group. Current research has also made possible the development of 2 new targeted gadolinium chelates, which look very promising, with the potential to improve cancer detection (for both MT218 and ProCA32.
View Article and Find Full Text PDFObjectives: Gadolinium-based contrast agents (GBCAs) are routinely used in magnetic resonance imaging (MRI) examinations. However, there is limited knowledge about the interaction with and distribution of the drug in human cells. This lack of knowledge is surprising, given that the first interaction of the drug occurs with blood cells.
View Article and Find Full Text PDFCorrect management of infants after minor head trauma is crucial to minimize the risk to miss clinically important traumatic brain injury (ciTBI). Current practices typically involve CT or in-hospital surveillance. Cranial ultrasound (CUS) provides a radiation-free and fast alternative.
View Article and Find Full Text PDFInterstitial lung disease (ILD) is now diagnosed by an ILD-board consisting of radiologists, pulmonologists, and pathologists. They discuss the combination of computed tomography (CT) images, pulmonary function tests, demographic information, and histology and then agree on one of the 200 ILD diagnoses. Recent approaches employ computer-aided diagnostic tools to improve detection of disease, monitoring, and accurate prognostication.
View Article and Find Full Text PDFMagnetic resonance imaging (MRI) is a technique useful for the diagnosis of cartilage damage due to high sensitivity to identify subchondral bone abnormalities and full-thickness cartilage lesions. The lack of a study on knee cartilage changes over time in patients with osteoarthritis (OA) by MRI technique led us to investigate the accuracy of MRI in identifying knee cartilage changes over time in patients with OA in a systematic review. In the present systematic review, started from the beginning of 2020 in one of the University Hospitals in Iran, the databases of CINAHL, Ovid, Elsevier, Scopus, PubMed, Science Direct, and Web of Science were searched using the keywords MRI, OA, Cartilage Lesion, Imaging Techniques.
View Article and Find Full Text PDFDespite current recommendations, there is no recent scientific study comparing the influence of CT reconstruction kernels on lung pattern recognition in interstitial lung disease (ILD).To evaluate the sensitivity of lung (i70) and soft (i30) CT kernel algorithms for the diagnosis of ILD patterns.We retrospectively extracted between 15-25 pattern annotations per case (1 annotation = 15 slices of 1 mm) from 23 subjects resulting in 408 annotation stacks per lung kernel and soft kernel reconstructions.
View Article and Find Full Text PDFManagement of severe postpartum hemorrhage (PPH) includes transcatheter pelvic arterial embolization (TAE). Data regarding subsequent fertility and obstetrical outcomes is limited, as most fertility outcomes derive from TAE in uterine fibroma. The purpose of our study was to evaluate the long-term outcomes of patients undergoing TAE, particularly concerning subsequent fertility and following pregnancies.
View Article and Find Full Text PDFBackground: Lung cancer is the leading cause of cancer-related deaths in Switzerland. Despite this, there is no lung cancer screening program in the country. In the United States, low-dose computed tomography (LDCT) lung cancer screening is partially established and endorsed by guidelines.
View Article and Find Full Text PDFLocoregional and distant metastases account for most cases of morbidity and mortality associated with melanoma. In addition, local recurrences of melanoma might be the onset of disseminated disease. Therefore, precise diagnosis and therapy are warranted to minimize morbidity and increase survival in a subset of patients.
View Article and Find Full Text PDFMagnetic resonance T1 mapping before and after Gd-EOB-DTPA administration allows quantification of the T1 reduction rate as a non-invasive surrogate marker of liver function. A major limitation of T1 relaxation time measurement is its dependency on MRI field strengths. Since T1 reduction rate is calculated as the relative shortening of T1 relaxation time before and after contrast administration, we hypothesized that the T1 reduction rate is comparable between 1.
View Article and Find Full Text PDFObjectives: This study was conducted to evaluate the effect of dose reduction on the performance of a deep learning (DL)-based computer-aided diagnosis (CAD) system regarding pulmonary nodule detection in a virtual screening scenario.
Methods: Sixty-eight anthropomorphic chest phantoms were equipped with 329 nodules (150 ground glass, 179 solid) with four sizes (5 mm, 8 mm, 10 mm, 12 mm) and scanned with nine tube voltage/current combinations. The examinations were analyzed by a commercially available DL-based CAD system.
Objective: The aim of the study was to use a software application to analyze the examination times and changeover times of two clinically highly applied MRI scanners at a university hospital for radiology and to evaluate whether this could result in optimization potential for examination planning in the daily clinical routine of MRI diagnostics.
Materials And Methods: Based on the newly developed software application "Teamplay Usage" (Siemens Healthineers, Germany), the examinations carried out on two MRI scanners (1.5 T and 3 T) were investigated within an analysis period of 12 months with regard to the type of examination and its duration.