Unlabelled: Fetal phonocardiography is a well-known auscultation technique for evaluation of fetal health. However, murmurs that are synchronous with the maternal heartbeat can often be heard while listening to fetal heart sounds. Maternal placental murmurs (MPM) could be used to detect maternal cardiovascular and placental abnormalities, but the recorded MPMs are often contaminated by ambient interference and noise.
View Article and Find Full Text PDFAims: Current early risk stratification of coronary artery disease (CAD) consists of pre-test probability scoring such as the 2019 ESC guidelines on chronic coronary syndromes (ESC2019), which has low specificity and thus rule-out capacity. A newer clinical risk factor model (risk factor-weighted clinical likelihood, RF-CL) showed significantly improved rule-out capacity over the ESC2019 model. The aim of the current study was to investigate if the addition of acoustic features to the RF-CL model could improve the rule-out potential of the best performing clinical risk factor models.
View Article and Find Full Text PDFConduction-induced heart failure in patients with left bundle branch block (LBBB) can benefit from cardiac resynchronization therapy (CRT). However, some patients are non-responders to the therapy with one contributing factor being poor optimization of the atrioventricular (AV) pacing delay. In this study, we have investigated the pacing-induced changes in the seismocardiogram (SCG).
View Article and Find Full Text PDFCardiovasc Eng Technol
December 2022
Aims: Recent technological advances enable diagnosing of obstructive coronary artery disease (CAD) from heart sound analysis with a high negative predictive value. However, the prognostic impact of this approach remains unknown. To investigate the prognostic value of heart sound analysis as two scores, the Acoustic-score and the CAD-score, in patients with suspected CAD which is treated according to standard of care.
View Article and Find Full Text PDFObjective: Seismocardiography is the measurement of vibration waves caused by the beating heart with accelerometer(s) placed on the chest. Investigating the nature and the behavior of these vibration waves, by comparing measurements from multiple sites, would help to understand the heart's mechanical contraction activity.
Approach: Using newly designed multichannel seismocardiogram equipment, it was possible to investigate the vibration waves with 16 three-axis sensors.
An amendment to this paper has been published and can be accessed via a link at the top of the paper.
View Article and Find Full Text PDFThe real time high frame rate (HFR) 2-dimensional ultrasound system, T5, at Duke University is capable of imaging at up to 1000 images per second for adult cardiac imaging. A method for detecting and visualizing the mechanical contraction fronts using HFR echocardioagraphy-derived Strain Rate Image (SRI) was described in 26 patients. The Tissue Shortening Onset front durations for echocardiographic normal patients were significantly shorter than conduction disorder patients with left bundle branch block (LBBB) with intrinsic conduction and conduction disorder patients without LBBB (non-LBBB) with simulated LBBB (sLBBB).
View Article and Find Full Text PDFThe purpose of this study was to investigate the correlation between the seismocardiogram and cardiorespiratory fitness. Cardiorespiratory fitness can be estimated as VOmax using non-exercise algorithms, but the results can be inaccurate. Healthy subjects were recruited for this study.
View Article and Find Full Text PDFBackground: The Fourth Universal Definition of Myocardial Infarction defines electrocardiographic Q waves as duration ≥30 ms and amplitude ≥1 mm or QS complex in 2 contiguous leads. However, current taskforce criteria may be overly restrictive. Therefore, we investigated the association of isolated, lenient, or strict Q waves with long-term outcome.
View Article and Find Full Text PDFCardiac time intervals are important hemodynamic indices and provide information about left ventricular performance. Phonocardiography (PCG), impedance cardiography (ICG), and recently, seismocardiography (SCG) have been unobtrusive methods of choice for detection of cardiac time intervals and have potentials to be integrated into wearable devices. The main purpose of this study was to investigate the accuracy and precision of beat-to-beat extraction of cardiac timings from the PCG, ICG and SCG recordings in comparison to multimodal echocardiography (Doppler, TDI, and M-mode) as the gold clinical standard.
View Article and Find Full Text PDFBackground: Out-of-hospital cardiac arrest (OHCA) is often the first manifestation of unrecognised cardiac disease. ECG abnormalities encountered in primary care settings may be warning signs of OHCA.
Objective: We examined the association between common ECG abnormalities and OHCA in a primary care setting.
Recently, we developed a high-frame-rate echocardiographic imaging system capable of acquiring images at rates up to 2500 per second. High imaging rates were used to quantify longitudinal strain parameters in patients with echocardiographically normal function. These data can serve as a baseline for comparing strain parameters in disease states.
View Article and Find Full Text PDFThe purpose of this work is to define fiducial points in the seismocardiogram (SCG) and to correlate them with physiological events identified in ultrasound images. For 45 healthy subjects the SCG and the electrocardiogram (ECG) were recorded simultaneously at rest. Immediately following the SCG and ECG recordings ultrasound images of the heart were also obtained at rest.
View Article and Find Full Text PDFObjectives: As the left vagus nerve (LVN) mediates a baroreflex blood pressure (BP) decrease, LVN stimulation (LVNS) could be a therapy for hypertension. Moreover, LVNS could elegantly be adjusted to the patient's actual BP and physical activity by using the neural information about BP and respiration extractable from LVN. However, unselective LVNS will trigger undesirable side-effects and therefore we here investigated the feasibility of using an intraneural electrode for extracting BP and respiration markers from the LVN and for selective LVNS.
View Article and Find Full Text PDFObjective: Diagnosing coronary artery disease (CAD) continues to require substantial healthcare resources. Acoustic analysis of transcutaneous heart sounds of cardiac movement and intracoronary turbulence due to obstructive coronary disease could potentially change this. The aim of this study was thus to test the diagnostic accuracy of a new portable acoustic device for detection of CAD.
View Article and Find Full Text PDFThe hypothesis of the study is that Torsades de pointes (TdP) history can be better identified using T-wave morphology compared to Fridericia-corrected QT interval (QTcF) at baseline. ECGs were recorded at baseline and during sotalol challenge in 20 patients with a history of TdP (+TdP) and 16 patients without previous TdP (-TdP). The QTcF and T-wave morphology combination score (MCS) were calculated.
View Article and Find Full Text PDFObjective: To investigate the association between maternal vascular murmurs (MVMs) and fetal growth restriction (defined as small-for-gestational-age [SGA] fetus) and abnormal Doppler pulsatility index (PI) of the uterine and/or umbilical arteries.
Methods: A cross-sectional study of women aged 18 years or older with a singleton pregnancy at 28-34 weeks was conducted at Regional Hospital Viborg, Denmark, between May 1 and August 1, 2013. Ultrasound fetal biometry was performed and the Doppler PI of the umbilical and uterine arteries was determined.
Objective: Left vagus nerve (LVN) stimulation (LVNS) has been tested for lowering the blood pressure (BP) in patients with resistant hypertension (RH). Whereas, closed-loop LVNS (CL-LVNS) driven by a BP marker may be superior to open-loop LVNS, there are situations (e.g.
View Article and Find Full Text PDFBiosens Bioelectron
December 2017
A novel therapeutic approach for treating resistant hypertension could be the use of bioelectronic medicines to achieve blood pressure (BP) control in implanted patients by closed-loop stimulation of the left vagus nerve (LVN). However, such a technology would require an implantable BP marker, which is not available yet. As it is known that the LVN conducts afferent BP-related signals, this study aimed to investigate if such signals could be recorded with implantable means and used to derive BP markers.
View Article and Find Full Text PDFBackground: Because of ambiguous reports in the literature, we aimed to investigate the association between PR interval and the risk of all-cause and cardiovascular death, heart failure, and pacemaker implantation, allowing for a nonlinear relationship.
Methods: We included 293,111 individuals, corresponding to one-third of the population in the greater region of Copenhagen. These individuals had a digital electrocardiogram recorded in a general practitioner's core facility from 2001-2011.
Objective: To characterize the vascular sounds of the uteroplacental blood flow obtained by microphones.
Methods: The present retrospective study took place in an anechoic chamber facility at Aalborg University, Aalborg, Denmark, in 2012, and included pregnant participants aged 18-40 years with a singleton pregnancy at 32-36 weeks and a parity of 0-2. Abdominal Doppler ultrasonography was performed bilaterally on the uterine arteries.
In this simulation study, a wireless passive LC-tank sensor system was characterized. Given the application of continuous bladder monitoring, a specific system was proposed in terms of coil geometries and electronic circuitry. Coupling coefficients were spatially mapped by simulation, as a function of both coil distance, and longitudinal and transverse translation of the sensor relative to the antenna.
View Article and Find Full Text PDF