J Cardiovasc Electrophysiol
January 2024
Introduction: Esophageal injury is one of the most serious complications of pulmonary vein isolation (PVI) with thermic energy sources. Better tissue selectivity of primarily non-thermic pulsed field ablation (PFA) may eliminate collateral injury, particularly the risk of atrio-esophageal fistula (AEF).
Objective: To compare the incidence of any (peri)-esophageal injury following PVI using PFA to thermic energy sources.
Introduction: Safety of pulmonary vein isolation (PVI) has been established in clinical studies. However, despite prevention efforts the incidence of damage to (peri)-esophageal tissue has not decreased, and the pathophysiology is incompletely understood. Damage to vagal nerve branches may be involved in lesion progression to atrio-esophageal fistula.
View Article and Find Full Text PDFPurpose: Inappropriate implantable cardioverter-defibrillator (ICD) shocks are associated with greater healthcare resource utilization, poorer quality-of-life, and higher mortality. We aimed to investigate the performance of enhanced supraventricular tachycardia (SVT) discrimination algorithms (morphology discrimination, rate stability, and sudden or chamber onset) for reducing inappropriate ICD therapies in patients with ICD/cardiac resynchronization therapy devices.
Methods: This prospective, non-randomized, multicenter study (ReduceIT) study took place at 56 sites across Germany and Estonia.
Aims: In the IN-TIME trial, automatic daily implant-based multiparameter telemonitoring significantly improved clinical outcomes in patients with chronic systolic heart failure and implantable cardioverter-defibrillator (ICD) or cardiac resynchronization therapy defibrillator (CRT-D). We compared IN-TIME results for ICD and CRT-D subgroups.
Methods: Patients with LVEF ≤ 35%, NYHA class II/III, optimized drug treatment, no permanent atrial fibrillation, and a dual-chamber ICD (n = 274) or CRT-D (n = 390) were randomized 1:1 to telemonitoring or no telemonitoring for 12 months.
Eur Heart J Qual Care Clin Outcomes
April 2019
Aims: Randomized clinical trials investigating a possible outcome effect of remote monitoring in patients with implantable defibrillators have shown conflicting results. This study analyses the information flow and workflow details from the IN-TIME study and discusses whether differences of message content, information speed and completeness, and workflow may contribute to the heterogeneous results.
Methods And Results: IN-TIME randomized 664 patients with an implantable cardioverter/defibrillator indication to daily remote monitoring vs.
Herzschrittmacherther Elektrophysiol
September 2016
With the introduction of edoxaban last year in Germany, four nonvitamin K antagonist oral anticoagulants are now available for stroke prevention in patients with nonvalvular atrial fibrillation. These novel oral anticoagulants (NOAC) represent an attractive new option compared to vitamin K antagonists (e.g.
View Article and Find Full Text PDFAims: Inadvertent lead malposition (ILM) in the left heart is a potential cause of thromboembolism and, therefore, a complication of heart rhythm device implantation [HRDI: pacemaker, implantable cardioverter defibrillator (ICD), cardiac resynchronization therapy (CRT)]. The aim of the study was to report the incidence and clinical outcome of ILM.
Methods And Results: Postoperative lateral and posterior-anterior chest X-rays of all consecutive patients undergoing HRDI from 2007 through 2012 were retrospectively analysed.
Aims: The aim of the study was to determine the level of pulmonary vein (PV) isolation achieved with the use of a novel radiofrequency circular multielectrode ablation catheter [pulmonary vein ablation catheter (PVAC)] in patients with paroxysmal atrial fibrillation. Although some efficacy data have been presented, the level of PV isolation, which is crucial both for efficacy and safety of the ablation, has not been defined with this new ablation catheter.
Methods And Results: Detailed sinus rhythm voltage maps using an electroanatomic mapping system and projected on 3D computed tomography-derived reconstructions of the left atrium (LA) were obtained before and after PV isolation with the PVAC.
Aims: The success in achieving treatment goals for cardiovascular risk factors in primary care is largely unknown. Therefore, the goals of this study were (i) to assess whether routinely collected practice data can be used to evaluate treatment in primary care, (ii) to compare current treatment with goals of published guidelines, and (iii) to calculate future risk for cardiovascular events using these real-life data.
Methods And Results: In 110 physician offices in Germany, data from the patient management systems of all patients seen between January 1998 and June 2005 were extracted and analysed (715 644) with current guidelines used for reference.
A congenital left ventricular aneurysm or diverticulum is a rare cardiac malformation described in 418 cases since the first description in 1816, being associated with other cardiac, vascular or thoracoabdominal abnormalities in about 75%. It appears to be a developmental anomaly, starting in the 4th embryonic week. Diagnosis can be made after exclusion of coronary artery disease, local or systemic inflammation or traumatic causes as well as cardiomyopathies.
View Article and Find Full Text PDF