Tribo-charging is often a root cause of mass flow deviations and powder adhesion during continuous feeding. Thus, it may critically impact product quality. In this study, we characterized the volumetric (split- and pre-blend) feeding behavior and process-induced charge of two direct compression grades of polyols, galenIQ™ 721 (G721) for isomalt and PEARLITOL 200SD (P200SD) for mannitol, under different processing conditions.
View Article and Find Full Text PDFWe show that introducing quenched disorder into a circle map leads to the suppression of quasiperiodic behavior in the limit of large system sizes. Specifically, for most parameters the fraction of disorder realizations showing quasiperiodicity decreases with the system size and eventually vanishes in the limit of infinite size, where almost all realizations show mode locking. Consequently, in this limit, and in strong contrast to standard circle maps, almost the whole parameter space corresponding to invertible dynamics consists of Arnold tongues.
View Article and Find Full Text PDFThe combination of computer-aided design (CAD) techniques based on computed tomography (CT) data to generate patient-specific implants is in use for decades. However, persisting disadvantages are complicated design procedures and rigid reconstruction protocols, for example, for tailored implants mimicking the patient-specific thickness distribution of missing cranial bone. In this study we used two different approaches, CAD- versus thin-plate spline (TPS)-based implants, to reconstruct extensive unilateral and bilateral cranial defects in three clinical cases.
View Article and Find Full Text PDFWe present visual methods for the analysis and comparison of the results of curved fibre reconstruction algorithms, i.e., of algorithms extracting characteristics of curved fibres from X-ray computed tomography scans.
View Article and Find Full Text PDFGross features of disc degeneration (DD) that are associated with back pain include tears in the anulus fibrosus, structural changes of the endplates, and a collapse of the anulus. The aim of this study is the detailed visualization and microstructural characterization of DD using microcomputed tomography (μCT) and a dedicated image post-processing pipeline. In detail, we investigate a cadaveric spine that shows both types of DD between L1 and L2 and between L2 and L3, respectively.
View Article and Find Full Text PDFBackground: Because of the accumulated numbers and the increasing rate of knee replacement surgeries larger numbers of revision cases are likely. Although the success rate of knee arthroplasties is high, complications like the loosening of the implant necessitate subsequent treatments. Therefore, new concepts such as metal-free ceramic implants are necessary, for example, using zirconium dioxide (ZrO).
View Article and Find Full Text PDFIEEE Trans Vis Comput Graph
August 2018
The comparison of many members of an ensemble is difficult, tedious, and error-prone, which is aggravated by often just subtle differences. In this paper, we introduce Dynamic Volume Lines for the interactive visual analysis and comparison of sets of 3D volumes. Each volume is linearized along a Hilbert space-filling curve into a 1D Hilbert line plot, which depicts the intensities over the Hilbert indices.
View Article and Find Full Text PDFThis work introduces a tool for interactive exploration and visualization using MetaTracts. MetaTracts is a novel method for extraction and visualization of individual fiber bundles and weaving patterns from X-ray computed tomography (XCT) scans of endless carbon fiber reinforced polymers (CFRPs). It is designed specifically to handle XCT scans of low resolutions where the individual fibers are barely visible, which makes extraction of fiber bundles a challenging problem.
View Article and Find Full Text PDFMost hominin cranial fossils are incomplete and require reconstruction prior to subsequent analyses. Missing data can be estimated by geometric morphometrics using information from complete specimens, for example, by using thin-plate splines. In this study, we estimate missing data in several virtually fragmented models of hominoid crania (Homo, Pan, Pongo) and fossil hominins (e.
View Article and Find Full Text PDFThis paper describes an advanced visualization method for the analysis of defects in industrial 3D X-Ray Computed Tomography (XCT) data. We present a novel way to explore a high number of individual objects in a dataset, e.g.
View Article and Find Full Text PDFIEEE Trans Vis Comput Graph
December 2011
Multi-material components, which contain metal parts surrounded by plastic materials, are highly interesting for inspection using industrial 3D X-ray computed tomography (3DXCT). Examples of this application scenario are connectors or housings with metal inlays in the electronic or automotive industry. A major problem of this type of components is the presence of metal, which causes streaking artifacts and distorts the surrounding media in the reconstructed volume.
View Article and Find Full Text PDFX-ray computed tomography (XCT) has become a very important method for non-destructive 3D-characterization and evaluation of materials. Due to measurement speed and quality, XCT systems with cone beam geometry and matrix detectors have gained general acceptance. Continuous improvements in the quality and performance of X-ray tubes and XCT devices have led to cone beam CT systems that can now achieve spatial resolutions down to 1 μm and even below.
View Article and Find Full Text PDFIEEE Trans Vis Comput Graph
December 2007
This paper describes a novel method for creating surface models of multi-material components using dual energy computed tomography (DECT). The application scenario is metrology and dimensional measurement in industrial high resolution 3D x-ray computed tomography (3DCT). Based on the dual source / dual exposure technology this method employs 3DCT scans of a high precision micro-focus and a high energy macro-focus x-ray source.
View Article and Find Full Text PDFClin Oral Implants Res
August 2007
Objectives: In this study, we present and evaluate a micro-computed tomography (micro-CT)-based method for the calculation of the potential bone/implant contact area (p-BICA) on the surface of dental implants.
Material And Methods: For seven commercially available implants (Ankylos implant, Brånemark System, Frialit CELLplus, Replace((R)) Select Tapered, Straumann Solid screw, XiVE S CELLplus, 3i Osseotite XP Threaded Miniplant, the p-BICA surface is determined by means of three-dimensional X-ray computed-tomography and computer-based data processing. Measurements were repeated two times, and the stability and repeatability of the measurement method were evaluated.
The pathological anatomy of idiopathic clubfoot has been investigated for more than 180 years using anatomy, computed tomography (CT), histology and microscopy. Seven idiopathic clubfeet and two normal feet of aborted fetuses were dissected in the present study, with special emphasis on the shape of the cartilage and bones. A three-dimensional (3D) micro-CT system, which generates a series of X-ray attenuation measurements, was used to produce computed reconstructed 3D data sets of each of the separated bones.
View Article and Find Full Text PDF