Purpose: In patients with end-stage heart failure who undergo left ventricular assist device (LVAD) implantation, higher pulmonary vascular resistance (PVR) is associated with higher right heart failure rates and ineligibility for heart transplant. Concomitant mitral regurgitation (MR) could potentially worsen pulmonary hemodynamics and lead to worse outcomes; however, its effects in this patient population have not been specifically examined.
Methods: Using an institutional database spanning November 2003 to August 2017, we retrospectively identified patients with elevated PVR who underwent LVAD implantation.
Patients with left ventricular assist devices (LVADs) receive anticoagulation to decrease the risk of thrombosis. Various circumstances require discontinuing anticoagulation in LVAD patients, but the risks entailed are not well defined. In a retrospective review of LVAD implantation procedures, we examined the effect of time off anticoagulation on thrombosis and mortality rates after implantation.
View Article and Find Full Text PDFPatients with severe refractory hypoxemic respiratory failure may benefit from extracorporeal membrane oxygenation (ECMO) for salvage therapy. The Coronavirus disease 2019 (COVID-19) pandemic offered three high-volume independent ECMO programs at a large medical center the chance to collaborate to optimize ECMO care at the beginning of the pandemic in Spring 2020. Between March 15, 2020, and May 30, 2020, 3,615 inpatients with COVID-19 were treated at the Texas Medical Center.
View Article and Find Full Text PDFObjectives: To evaluate the safety and accuracy of the Early Bird Bleed Monitoring System (EBBMS; Saranas) for the detection of access-site related bleeds in humans undergoing endovascular procedures.
Background: Bleeding complications after endovascular procedures are frequent and associated with poor prognosis. The EBBMS is a novel technology designed to detect in real time the onset, progression, and severity of internal bleeds.
Gen Thorac Cardiovasc Surg
November 2020
Objective: Warfarin is standard anticoagulation therapy for patients with a continuous-flow left ventricular assist device (CF-LVAD). However, warfarin requires regular monitoring and dosage adjustments and fails for many patients, causing thromboembolic and bleeding events. Factor Xa inhibitors have been shown to be noninferior to warfarin in preventing strokes and are associated with less intracranial hemorrhage in patients with atrial fibrillation.
View Article and Find Full Text PDFA 56-year-old man who had twice previously undergone orthotopic heart transplantation was admitted with dyspnea and heart failure symptoms. A biopsy excluded rejection. Left heart catheterization revealed a coronary cameral fistula.
View Article and Find Full Text PDFContinuous-flow left ventricular assist devices (CF-LVADs) are increasingly being used to treat advanced, refractory chronic heart failure. Herein, we sought to determine the incidence of postoperative acute kidney injury (AKI) in axial-flow (HeartMate II; HM-II) and centrifugal-flow (HVAD) CF-LVAD recipients, as well as the effect of AKI on mortality. The study cohort comprised 520 patients who received a HM-II (n = 398) or HVAD (n = 122) at our center between November 2003 and March 2016.
View Article and Find Full Text PDFBackground: Continuous-flow left ventricular assist devices (LVADs) expose blood cells to high shear stress, potentially resulting in the production of microparticles that express phosphatidylserine (PS+) and promote coagulation and inflammation. In this prospective study, we attempted to determine whether PS+ microparticle levels correlate with clinical outcomes in LVAD-supported patients.
Methods: We enrolled 20 patients undergoing implantation of the HeartMate II LVAD (Thoratec Corp, Pleasanton, CA) and 10 healthy controls who provided reference values for the microparticle assays.
Currently, long-term mechanical circulatory support (MCS) is limited to large, complex devices that require invasive, high-risk surgical implantation. These devices are mainly used in patients with late stage heart failure (HF). We are developing a novel percutaneous intra-aortic micro-axial fluid entrainment pump intended for long-term MCS in patients with earlier stage HF.
View Article and Find Full Text PDFWe report the case of a patient who had chronic anthracycline-induced cardiomyopathy that was reversed after treatment with a left ventricular assist device. A 29-year-old woman had undergone anthracycline-based chemotherapy as a teenager in 1991 and 1992 and received a diagnosis of dilated cardiomyopathy 10 years later. Optimal medical therapy had initially controlled the symptoms of heart failure.
View Article and Find Full Text PDF