Publications by authors named "Joerg Schmiedeskamp"

The aim of this study was to validate oxygen-sensitive 3He-MRI in noninvasive determination of the regional, two- and three-dimensional distribution of oxygen partial pressure. In a gas-filled elastic silicon ventilation bag used as a lung phantom, oxygen sensitive two- and three-dimensional 3He-MRI measurements were performed at different oxygen concentrations which had been equilibrated in a range of normal and pathologic values. The oxygen partial pressure distribution was determined from 3He-MRI using newly developed software allowing for mapping of oxygen partial pressure.

View Article and Find Full Text PDF

Purpose: To assess the emphysematous enlargement of distal airspaces and concomitant large and small airway disease using diffusion-weighted Helium-magnetic resonance imaging (MRI), high-resolution computed tomography (HRCT), and lung function tests (LFT).

Methods: Seven patients were examined after single lung transplantation (LTx) and 1 before double LTx for various forms of emphysema. Five patients after double LTx served as controls.

View Article and Find Full Text PDF

The aim of this study was to evaluate the possible contribution of (3)He-MRI to detect obliterative bronchiolitis (OB) in the follow-up of lung transplant recipients. Nine single- and double-lung transplanted patients were studied by an initial and a follow-up (3)He-MRI study. Images were evaluated subjectively by estimation of ventilation defect area and quantitatively by individually adapted threshold segmentation and subsequent calculation of ventilated lung volume.

View Article and Find Full Text PDF

Rationale And Objectives: The ability of motion corrected dynamic 3He-magnetic resonance imaging (MRI) to discriminate distributional patterns of inhaled hyperpolarized 3He between different groups of lung transplant recipients was evaluated.

Methods: An ultrafast low-angle shot 2D sequence (temporal resolution 128 ms) was used for ventilation 3He-MRI of 11 single and 6 double lung transplant recipients. After digital motion correction, signal kinetics were evaluated in a tracheal and 7 pulmonary regions of interest.

View Article and Find Full Text PDF

Purpose: To elucidate the ability of 3He-MRI to detect ventilation defects in lung transplant recipients, 3He-MRI was compared to CT for concordance.

Materials And Methods: We examined 14 lung recipients using 3He-MRI on a 1.5 T MR scanner.

View Article and Find Full Text PDF

Rationale And Objectives: Software was developed to correct for lung motion to improve the description of hyperpolarized (3)He gas distribution in the lung.

Methods: Five volunteers were studied by dynamic ventilation (3)He-MRI using an ultrafast FLASH 2D sequence with a temporal resolution of 128 milliseconds. Signal kinetics were evaluated in the trachea and seven parenchymal Regions of Interest.

View Article and Find Full Text PDF