Background: A coded aperture X-ray diffraction (XRD) imaging system can measure the X-ray diffraction form factor from an object in three dimensions -X, Y and Z (depth), broadening the potential application of this technology. However, to optimize XRD systems for specific applications, it is critical to understand how to predict and quantify system performance for each use case.
Objective: The purpose of this work is to present and validate 3D spatial resolution models for XRD imaging systems with a detector-side coded aperture.
Spreading depolarizations (SD) refer to the near-complete depolarization of neurons that is associated with brain injuries such as ischemic stroke. The present gold standard for SD monitoring in humans is invasive electrocorticography (ECoG). A promising non-invasive alternative to ECoG is diffuse optical monitoring of SD-related flow and hemoglobin transients.
View Article and Find Full Text PDFSignificance: Cerebral metabolic rate of oxygen ( ) consumption is a key physiological variable that characterizes brain metabolism in a steady state and during functional activation.
Aim: We aim to develop a minimally invasive optical technique for real-time measurement of concurrently with cerebral blood flow (CBF).
Approach: We used a pair of macromolecular phosphorescent probes with nonoverlapping optical spectra, which were localized in the intra- and extravascular compartments of the brain tissue, thus providing a readout of oxygen gradients between these two compartments.
Purpose: Recent studies have demonstrated the ability to rapidly produce large field of view X-ray diffraction (XRD) images, which provide rich new data relevant to the understanding and analysis of disease. However, work has only just begun on developing algorithms that maximize the performance toward decision-making and diagnostic tasks. In this study, we present the implementation of and comparison between rules-based and machine learning (ML) classifiers on XRD images of medically relevant phantoms to explore the potential for increased classification performance.
View Article and Find Full Text PDFX-ray transmission imaging has been used in a variety of applications for high-resolution measurements based on shape and density. Similarly, X-ray diffraction (XRD) imaging has been used widely for molecular structure-based identification of materials. Combining these X-ray methods has the potential to provide high-resolution material identification, exceeding the capabilities of either modality alone.
View Article and Find Full Text PDFBackground: The cortical microvascular cerebral blood flow response (CBF) to different changes in head-of-bed (HOB) position has been shown to be altered in acute ischemic stroke (AIS) by diffuse correlation spectroscopy (DCS) technique. However, the relationship between these relative ΔCBF changes and associated systemic blood pressure changes has not been studied, even though blood pressure is a major driver of cerebral blood flow.
Methods: Transcranial DCS data from four studies measuring bilateral frontal microvascular cerebral blood flow in healthy controls (n = 15), patients with asymptomatic severe internal carotid artery stenosis (ICA, n = 27), and patients with acute ischemic stroke (AIS, n = 72) were aggregated.
X-ray diffraction (XRD) imaging yields spatially resolved, material-specific information, which can aid medical diagnosis and inform treatment. In this work we used simulations to analyze the utility of fan beam coded aperture XRD imaging for fast, high-resolution scatter imaging of biospecimens for tissue assessment. To evaluate the proposed system's utility in a specific task, we employed a deterministic model to produce simulated data from biologically realistic breast tissue phantoms and model-based reconstruction to recover a spatial map of the XRD signatures throughout the phantoms.
View Article and Find Full Text PDFImaging through opaque scattering media is critically important in applications ranging from biological and astronomical imaging to metrology and security. While the random process of scattering in turbid media produces scattered light that appears uninformative to the human eye, a wealth of information is contained in the signal and can be recovered using computational post-processing techniques. Recent studies have shown that statistical correlations present in the scattered light, known as 'memory effects', allow for diffraction-limited imaging through opaque media without detailed knowledge of (or access to) the source or scatterer.
View Article and Find Full Text PDFGlutamate Chemical Exchange Saturation Transfer (GluCEST) MRI is a recently developed technique to image glutamate. In the present study, we evaluated the reproducibility and background contamination to the GluCEST and source of the GluCEST changes in a mouse model of Parkinson's disease. Repeated measurements in five mice demonstrated an intra-animal coefficient of variation (CV) of GluCEST signal to be 2.
View Article and Find Full Text PDFX-ray diffraction tomography (XDT) records the spatially-resolved X-ray diffraction profile of an extended object. Compared to conventional transmission-based tomography, XDT displays high intrinsic contrast among materials of similar electron density and improves the accuracy in material identification thanks to the molecular structural information carried by diffracted photons. However, due to the weak diffraction signal, a tomographic scan covering the entire object typically requires a synchrotron facility to make the acquisition time more manageable.
View Article and Find Full Text PDFThe critical closing pressure ( CrCP) of the cerebral circulation depends on both tissue intracranial pressure and vasomotor tone. CrCP defines the arterial blood pressure ( ABP) at which cerebral blood flow approaches zero, and their difference ( ABP - CrCP) is an accurate estimate of cerebral perfusion pressure. Here we demonstrate a novel non-invasive technique for continuous monitoring of CrCP at the bedside.
View Article and Find Full Text PDFAlthough transmission-based x-ray imaging is the most commonly used imaging approach for breast cancer detection, it exhibits false negative rates higher than 15%. To improve cancer detection accuracy, x-ray coherent scatter computed tomography (CSCT) has been explored to potentially detect cancer with greater consistency. However, the 10-min scan duration of CSCT limits its possible clinical applications.
View Article and Find Full Text PDFGlutamate chemical exchange saturation transfer (GluCEST) MRI was used to measure metabolic changes in mice treated with 1-methyl-4-phenyl-1,2,3,6-tetrahydropyridine (MPTP) by mapping regional cerebral glutamate. The GluCEST contrast following MPTP treatment was correlated with H-MR spectroscopy, motor function, and immunohistochemical measures. The GluCEST contrast was found to be significantly higher in the striatum and motor cortex of mice treated with MPTP than in controls (p < 0.
View Article and Find Full Text PDFWe use coherently scattered X-rays to measure the molecular composition of an object throughout its volume. We image a planar slice of the object in a single snapshot by illuminating it with a fan beam and placing a coded aperture between the object and the detectors. We characterize the system and demonstrate a resolution of 13 mm in range and 2 mm in cross-range and a fractional momentum transfer resolution of 15%.
View Article and Find Full Text PDFA scatter imaging technique for the differentiation of cancerous and healthy breast tissue in a heterogeneous sample is introduced in this work. Such a technique has potential utility in intraoperative margin assessment during lumpectomy procedures. In this work, we investigate the feasibility of the imaging method for tumor classification using Monte Carlo simulations and physical experiments.
View Article and Find Full Text PDFWe introduce and validate a pressure measurement paradigm that reduces extracerebral contamination from superficial tissues in optical monitoring of cerebral blood flow with diffuse correlation spectroscopy (DCS). The scheme determines subject-specific contributions of extracerebral and cerebral tissues to the DCS signal by utilizing probe pressure modulation to induce variations in extracerebral blood flow. For analysis, the head is modeled as a two-layer medium and is probed with long and short source-detector separations.
View Article and Find Full Text PDFWe develop and validate a Modified Beer-Lambert law for blood flow based on diffuse correlation spectroscopy (DCS) measurements. The new formulation enables blood flow monitoring from temporal intensity autocorrelation function data taken at single or multiple delay-times. Consequentially, the speed of the optical blood flow measurement can be substantially increased.
View Article and Find Full Text PDFX-ray scattering has played a key role in non-destructive materials characterization due to the material-specific coherent scattering signatures. In the current energy dispersive coherent scatter imaging systems, including selected volume tomography and coherent scatter computed tomography, each object voxel is measured at a single scatter angle, which suffers from slow acquisition time. The employment of coded apertures in x-ray scatter imaging systems improves the photon collection efficiency, making it promising for real time volumetric imaging and material identification.
View Article and Find Full Text PDFWe realize a strongly dispersive material with large tunable group velocity dispersion (GVD) in a commercially-available photonic crystal fiber. Specifically, we pump the fiber with a two-frequency pump field that induces an absorbing resonance adjacent to an amplifying resonance via the stimulated Brillouin processes. We demonstrate all-optical control of the GVD by measuring the linear frequency chirp impressed on a 28-nanosecond-duration optical pulse by the medium and find that it is tunable over the range ± 7.
View Article and Find Full Text PDFBackground And Purpose: A primary goal of acute ischemic stroke (AIS) management is to maximize perfusion in the affected region and surrounding ischemic penumbra. However, interventions to maximize perfusion, such as flat head-of-bed (HOB) positioning, are currently prescribed empirically. Bedside monitoring of cerebral blood flow (CBF) allows the effects of interventions such as flat HOB to be monitored and may ultimately be used to guide clinical management.
View Article and Find Full Text PDFWe present a method for realizing snapshot, depth-resolved material identification using only a single, energy-sensitive pixel. To achieve this result, we employ a coded aperture with subpixel features to modulate the energy spectrum of coherently scattered photons and recover the object properties using an iterative inversion algorithm based on compressed sensing theory. We demonstrate high-fidelity object estimation at x-ray wavelengths for a variety of compression ratios exceeding unity.
View Article and Find Full Text PDFTomographic imaging of the molecular structure of an object is important for a variety of applications, ranging from medical and industrial radiography to security screening. X-ray diffraction imaging is the preeminent technique for performing molecular analysis of large volumes. Here we propose and demonstrate a new measurement architecture to improve the source and detector efficiency for diffraction imaging.
View Article and Find Full Text PDFWe demonstrate a technique for measuring the range-resolved coherent scatter form factors of different objects from a single snapshot. By illuminating the object with an x-ray pencil beam and placing a coded aperture in front of a linear array of energy-sensitive detector elements, we record the coherently scattered x-rays. This approach yields lateral, range, and momentum transfer resolutions of 1 mm, 5 mm, and 0.
View Article and Find Full Text PDFThe Brain Research through Advancing Innovative Neurotechnologies (BRAIN) Initiative has focused scientific attention on the necessary tools to understand the human brain and mind. Here, we outline our collective vision for what we can achieve within a decade with properly targeted efforts and discuss likely technological deliverables and neuroscience progress.
View Article and Find Full Text PDFA pilot study explores relative contributions of extra-cerebral (scalp/skull) versus brain (cerebral) tissues to the blood flow index determined by diffuse correlation spectroscopy (DCS). Microvascular DCS flow measurements were made on the head during baseline and breath-holding/hyperventilation tasks, both with and without pressure. Baseline (resting) data enabled estimation of extra-cerebral flow signals and their pressure dependencies.
View Article and Find Full Text PDF