Clin Oral Investig
February 2024
Objective: This study aimed to compare the efficacy of acellular xenogeneic dermal matrix graft (AXDM) compared to connective tissue graft (CTG) in treating multiple gingival recessions.
Materials And Methods: A systematic search of electronic databases was conducted to identify randomized clinical trials (RCTs) that compared AXDM and CTG. The selected studies were subjected to bias risk assessment, data extraction, and meta-analyses.
The objective of this systematic review was to identify the available scientific evidence on bone substitutes (BSs) compared with autogenous bone grafts (ABGs) for regeneration of horizontal bone resorption in the anterior maxillary alveolar process, aiming at rehabilitation with endosseous implants. This review was performed according to the PRISMA guidelines (2020) and registered in the database PROSPERO (CRD: 42017070574). The databases searched were PUBMED/MEDLINE, EMBASE, SCOPUS, SCIENCE DIRECT, WEB OF SCIENCE, and CENTRAL COCHRANE, in the English language.
View Article and Find Full Text PDFThe objective of this study was to perform a quality analysis of systematic reviews with meta-analyses that focused on the comparison of platform-switching (implant-abutment mismatching) and platform-matched (PM) implants. The assessment of multiple systematic reviews (AMSTAR) and Glenny (Checklist) Scales were used to qualify the studies. PubMed, Scientific Electronic Library Online (SciELO), Web of Science (formerly ISI Web of Knowledge), and Cochrane databases were searched, by topic, for systematic reviews on dental implants with switching platforms.
View Article and Find Full Text PDFThe purpose of this study was to perform a systematic review of morphological alterations in the condyles after orthographic surgery involving a sagittal split ramus osteotomy (SSRO), with or without surgery on the maxilla. Searches were performed on three databases and registered in the PROSPERO. The selected studies fulfilled the criteria established by the following PICO model: (1) population: individuals with skeletal dentofacial deformities (class II or III facial patterns), without asymmetry; (2) intervention: orthognathic surgery for mandibular setback using an SSRO, with or without a Le Fort I osteotomy, and fixed with bicortical screws or plates and screws; (3) comparison: orthognathic surgery for mandibular advancement using an SSRO, with or without a Le Fort I osteotomy, and fixed with plates and screws or bicortical screws; and (4) outcome: condylar resorption rate and relapse.
View Article and Find Full Text PDFThe aim of this study was to evaluate the effect of varying the diameter, connection type and loading on stress distribution in the cortical bone for implants with a high crown-implant ratio. Six 3D models were simulated with the InVesalius, Rhinoceros 3D 4.0 and SolidWorks 2011 software programs.
View Article and Find Full Text PDFThe purpose of this study was to evaluate different retention systems (cement- or screw-retained) and crown designs (non-splinted or splinted) of fixed implant-supported restorations, in terms of stress distributions in implants/components and bone tissue, by 3-dimensional (3D) finite element analysis. Four 3D models were simulated with the InVesalius, Rhinoceros 3D, and SolidWorks programs. Models were made of type III bone from the posterior maxillary area.
View Article and Find Full Text PDFInt J Oral Maxillofac Implants
January 2018
Purpose: The aim of this study was to use three-dimensional finite element analysis to analyze the stress distribution transferred by single implant-supported prostheses placed in the anterior maxilla using different connections (external hexagon, internal hexagon, or Morse taper), inclinations of the load (0, 30, or 60 degrees), and surgical techniques for placement (monocortical/conventional, bicortical, or bicortical with nasal floor elevation).
Materials And Methods: Nine models representing a bone block of this region were simulated by computer-aided design software (InVesalius, Rhinoceros, SolidWorks). Each model received one implant, which supported a cemented metalloceramic crown.
Mater Sci Eng C Mater Biol Appl
February 2017
A biomechanical analysis of different types of implant connections is relevant to clinical practice because it may impact the longevity of the rehabilitation treatment. Therefore, the objective of this study is to evaluate the Morse taper connections and the stress distribution of structures associated with the platform switching (PSW) concept. It will do this by obtaining data on the biomechanical behavior of the main structure in relation to the dental implant using the 3-dimensional finite element methodology.
View Article and Find Full Text PDFStatement Of Problem: Radiotherapy has been considered a contraindication for rehabilitation with dental implants because it can change the survival rate of implants. Nevertheless, the installation of implants in irradiated patients has been used with varying success.
Purpose: The purpose of this systematic review was to compare the success rate of implants placed in irradiated human bone tissue with that of implants placed in nonirradiated areas.
Purpose: To evaluate a modified experimental model for medication-related osteonecrosis of the jaw (MRONJ) through the upper right central incisor extraction followed by intravenous bisphosphonate administration.
Methods: Forty five rats underwent the upper right central incisor tooth extraction were divided in 2 groups: Group I - experimental group, 30 rats received an intravenous administration protocol of zoledronic acid 35μg/kg into the tail vein every two weeks, totalizing four administrations, during eight weeks of administration, previously the extraction, and Group II - control group, 15 rats didn't received any medication before extraction. The groups were subdivided in postoperative periods: 14/28/42 days.
Aim: This paper describes a case of a rehabilitation involving Computer Aided Design/Computer Aided Manufacturing (CAD-CAM) system in implant supported and dental supported prostheses using zirconia as framework.
Background: The CAD-CAM technology has developed considerably over last few years, becoming a reality in dental practice. Among the widely used systems are the systems based on zirconia which demonstrate important physical and mechanical properties of high strength, adequate fracture toughness, biocompatibility and esthetics, and are indicated for unitary prosthetic restorations and posterior and anterior framework.
The aim of this study was to evaluate stress distribution in the fixation screws and bone tissue around implants in single-implant supported prostheses with crowns of different heights (10, 12.5, 15 mm - crown-to-implant ratio 1:1, 1.25:1, 1.
View Article and Find Full Text PDFJ Periodontol
February 2014
Purpose: The aim of this study was to evaluate the bone repair process in the maxillary sinus in monkeys treated with high-density porous polyethylene (Medpor)
Methods: Four capuchin monkeys (Cebus apella) were submitted to bilateral horizontal osteotomies in the anterior wall of the maxillary sinus and divided into 2 groups: control group, left side with no implants, and porous polyethylene group, right side with Medpor. After a period of 145 days after implant placement, the maxillae were removed for histologic and histometric analyses.
Results: Bone repair in osteotomized areas took place by connective tissue in 58.
The prosthetic treatments play a role in the rehabilitation of patients with congenital and acquired cleft palate. To prepare the surgical field and/or correct inevitable sequelae of the surgery, the rehabilitation with obturator prosthesis is an auxiliary or complementary treatment to surgical treatments. In cases where the surgical treatment is contraindicated, the prosthetic rehabilitation becomes a definitive treatment.
View Article and Find Full Text PDFThe use of craniofacial implants is an effective treatment for patients with deformities, burns, and cancer sequelae. The sites with the most successful implants are the auricular, nasal, and orbital regions. Furthermore, other factors can affect the implant longevity such as irradiated area, surgical technique, bone quality and quantity, macrostructure and microstructure of the implant, maintenance, and systemic factors.
View Article and Find Full Text PDFThe aim of this study was to evaluate the stress distribution of platform switching implants using a photoelastic method. Three models were constructed of the photoelastic resin PL-2, with a single implant and a screw-retained implant-supported prosthesis. These models were Model A, platform 5.
View Article and Find Full Text PDFFluoride has been widely used in dentistry as a caries prophylactic agent. However, there has been some speculation that excess fluoride could cause an impact on genome integrity. In the current study, the potential DNA damage associated with exposure to fluoride was assessed in cells of blood, liver, kidney, thyroid gland and urinary bladder by the single cell gel (comet) assay.
View Article and Find Full Text PDF