Publications by authors named "Jochen Steinmann"

Viral disinfection is important for medical facilities, the food industry, and the veterinary field, especially in terms of controlling virus outbreaks. Therefore, standardized methods and activity levels are available for these areas. Usually, disinfectants used in these areas are characterized by their activity against test organisms (i.

View Article and Find Full Text PDF

The spread of nonzoonotic monkeypox virus (MPXV) infections necessitates the reevaluation of hygiene measures. To date, only limited data are available on MPXV surface stability. Here, we evaluate the stability of infectious MPXV on stainless steel stored at different temperatures, while using different interfering substances to mimic environmental contamination.

View Article and Find Full Text PDF

Background: Adenoviruses belong to the stable nonenveloped viruses playing an important role in healthcare-associated infections mainly causing respiratory infections and epidemic keratoconjunctivitis. Hand disinfection with alcoholic preparations is therefore one of the most important measures to prevent such viral infections in hospitals and other medical settings.

Methods: The inactivation of adenovirus type 5 by ethanol, 1- and 2-propanol, and 2 commercially available hand disinfectants was examined at different concentrations, temperatures, and pH-values.

View Article and Find Full Text PDF

Background & Aims: Hepatitis E virus (HEV) is the most common cause of acute viral hepatitis worldwide and is mainly transmitted via the fecal-oral route or through consumption of contaminated food products. Due to the lack of efficient cell culture systems for the propagation of HEV, limited data regarding its sensitivity to chemical disinfectants are available. Consequently, preventive and evidence-based hygienic guidelines on HEV disinfection are lacking.

View Article and Find Full Text PDF

Disinfection measures have become more important as a result of the COVID-19 pandemic in Germany. The increased need for disinfectants at the beginning of the pandemic required temporary legal regulations in order to provide a sufficient quantity of products for the necessary disinfection in the medical sector on the one hand and for the additional demand in the population on the other. For this purpose, the Federal Institute for Drugs and Medical Devices (BfArM) and the Federal Institute for Occupational Safety and Health (BAuA) issued a general ruling, which is explained in more detail in this article.

View Article and Find Full Text PDF

Human papillomaviruses (HPV) are non-enveloped DNA viruses infecting cutaneous and mucosal squamous epithelia. Sexually transmitted HPV-types that are carcinogenic to humans such as HPV16 can induce cervical and other anogenital cancers. Virus transmission through fomites such as inadequately disinfected gynecological equipment is a further potential transmission route.

View Article and Find Full Text PDF

On-bike systems warning cyclists about critical situations are a promising approach to improve safety. The chosen warning modality might strongly influence whether the cyclist accepts the system. So far, cyclists' warning preferences have not been analyzed based on field data.

View Article and Find Full Text PDF

Glutaraldehyde (GDA) is an active ingredient in many instrument disinfectants and is effective against a broad spectrum of microorganisms. In the past, the virus-inactivating properties of these products were mainly claimed based on quantitative suspension tests with different test viruses. Recently, however, a European Norm EN 17111:2018 has been published which allows examination of instrument disinfectants in a surface carrier test, simulating practical conditions.

View Article and Find Full Text PDF

The ongoing severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) pandemic creates a significant threat to global health. Recent studies suggested the significance of throat and salivary glands as major sites of virus replication and transmission during early coronavirus disease 2019, thus advocating application of oral antiseptics. However, the antiviral efficacy of oral rinsing solutions against SARS-CoV-2 has not been examined.

View Article and Find Full Text PDF

During the World War II jaundice and hepatitis in the US army were observed after vaccination with the yellow fever vaccine containing human plasma for stabilization. This led to first heat experiments with volunteers without knowledge of the causative agents. Finally, experiments of human serum with volunteers and chimpanzees led to the conclusion that the hepatitis B virus (HBV) which had been identified as the responsible agent of the contamination of the vaccine, could not be inactivated at 98°C after 1 min, whereas 2 min in two chimpanzees were enough.

View Article and Find Full Text PDF

Background: The use of disinfectant wipes in hospitals is increasing over the last years. These wipes should be able to inactivate microorganisms including viruses on environmental surfaces and to prevent their transfer to clean areas.The European norm (EN) 16615:2015 describes a wiping process over four fields starting on the contaminated field 1 followed by fields 2-4 and back to the starting point (4-field test).

View Article and Find Full Text PDF

Hepatitis B virus (HBV) infection is considered a major public health problem worldwide, and a significant number of reports on nosocomial and occupational outbreaks have been reported. This systematic investigation of HBV stability and susceptibility to different antiseptics revealed that HBV infectivity was very stable, with a half-life of >22 days at 37°C. At 4°C, infectivity was barely reduced for up to 9 months.

View Article and Find Full Text PDF

Background: Various peracetic-acid (PAA)-based products for processing flexible endoscopes on the market are often based on a two-component system including a cleaning step before the addition of PAA as disinfectant. The peracetic acid concentrations in these formulations from different manufacturers are ranging from 400 to 1500 ppm (part per million). These products are used at temperatures between 20 °C and 37 °C.

View Article and Find Full Text PDF

The World Health Organization (WHO) published 2 alcohol-based formulations to be used in healthcare settings and for outbreak-associated infections, but inactivation efficacies of these products have not been determined against (re-)emerging viruses. In this study, we evaluated the virucidal activity of these WHO products in a comparative analysis. Zika virus (ZIKV), Ebola virus (EBOV), severe acute respiratory syndrome coronavirus (SARS-CoV), and Middle East respiratory syndrome coronavirus (MERS-CoV) as (re-)emerging viral pathogens and other enveloped viruses could be efficiently inactivated by both WHO formulations, implicating their use in healthcare systems and viral outbreak situations.

View Article and Find Full Text PDF

The virucidal efficacy of an automated ultrasound probe disinfector (trophon EPR) was evaluated in a three step procedure according to European and German test methods. This system uses sonicated hydrogen peroxide mist (35%) at elevated temperature (50°C) in a closed chamber with control of all parameters within a 7 minute cycle. In the first step of examination, the peroxide solution was tested in a quantitative suspension assay according to the Guideline of Deutsche Vereinigung zur Bekämpfung der Viruskrankheiten (DVV) e.

View Article and Find Full Text PDF

Background: Hand disinfectants are important for the prevention of virus transmission in the health care system and environment. The development of broad antiviral spectrum hand disinfectants with activity against enveloped and non-enveloped viruses is limited due to a small number of permissible active ingredients able to inactivate viruses.

Methods: A new hand disinfectant was developed based upon 69.

View Article and Find Full Text PDF

Virus inactivation by chemical disinfectants is an important instrument for infection control in medical settings, but the mechanisms involved are poorly understood. In this study, we systematically investigated the effects of several antiviral treatments on hepatitis C virus (HCV) particles as model for enveloped viruses. Studies were performed with authentic cell culture-derived viruses, and the influence of chemical disinfectants, heat, and UV treatment on HCV was analyzed by the determination of infectious particles in a limiting-dilution assay, by quantitative reverse transcription-PCR, by core enzyme-linked immunosorbent assay, and by proteolytic protection assay.

View Article and Find Full Text PDF

Surface disinfectants are part of broader preventive strategies preventing the transmission of bacteria, fungi and viruses in medical institutions. To evaluate their virucidal efficacy, these products must be tested with appropriate model viruses with different physico-chemical properties under conditions representing practical application in hospitals. The aim of this study was to evaluate a quantitative carrier assay.

View Article and Find Full Text PDF

Background: A recently modified World Health Organization (WHO) Formulation I was examined as 80% and 97% solutions against poliovirus type 1, adenovirus type 5 and murine norovirus according to the new European Norm prEN 14476:2011. In a previous study the unmodified WHO Formulation I had failed to demonstrate a sufficient activity against poliovirus type 1 according to the European Norm EN 14476-2007 whereas a sufficient activity was seen with adeno- and norovirus.

Findings: The modified WHO Formulation I demonstrated a virucidal activity against all 3 test viruses of the European Norm prEN 14476:2011 under clean conditions.

View Article and Find Full Text PDF

Background: Hepatitis C virus (HCV) is spread through direct contact with blood, although alternative routes of transmission may contribute to the global burden. Perinatal infection occurs in up to 5% of HCV-infected mothers, and presence of HCV RNA in breast milk has been reported. We investigated the influence of breast milk on HCV infectiousness.

View Article and Find Full Text PDF

Background: Hepatitis C virus (HCV) cross-contamination from inanimate surfaces or objects has been implicated in transmission of HCV in health-care settings and among injection drug users. We established HCV-based carrier and drug transmission assays that simulate practical conditions to study inactivation and survival of HCV on inanimate surfaces.

Methods: Studies were performed with authentic cell culture derived viruses.

View Article and Find Full Text PDF

A PHP Error was encountered

Severity: Warning

Message: fopen(/var/lib/php/sessions/ci_sessioneb5cv33lom0vgb6kocsb9gv79fv26s3b): Failed to open stream: No space left on device

Filename: drivers/Session_files_driver.php

Line Number: 177

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_start(): Failed to read session data: user (path: /var/lib/php/sessions)

Filename: Session/Session.php

Line Number: 137

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once