Rapid mapping of the mechanical properties of soft biological tissues from light microscopy to macroscopic imaging can transform fundamental biophysical research by providing clinical biomarkers to complement in vivo elastography. This work introduces superfast optical multifrequency time-harmonic elastography (OMTHE) to remotely encode surface and subsurface shear wave fields for generating maps of tissue stiffness with unprecedented detail resolution. OMTHE rigorously exploits the space-time propagation characteristics of multifrequency time-harmonic waves to address current limitations of biomechanical imaging and elastography.
View Article and Find Full Text PDFBackground: The precise role of the acromioclavicular and coracoclavicular ligaments during shoulder motion is unclear. We evaluate changes in the stress-strain distribution of the acromioclavicular joint's ligaments during different shoulder passive motion positions.
Methods: A 3D acromioclavicular joint model was reconstructed.
Background And Purpose: Prognostic models based on cardiovascular hemodynamic parameters may bring new information for an early assessment of patients with bicuspid aortic valve (BAV), playing a key role in reducing the long-term risk of cardiovascular events. This work quantifies several three-dimensional hemodynamic parameters in different patients with BAV and ranks their relationships with aortic diameter.
Materials And Methods: Using 4D-flow CMR data of 74 patients with BAV (49 right-left and 25 right-non-coronary) and 48 healthy volunteers, aortic 3D maps of seventeen 17 different hemodynamic parameters were quantified along the thoracic aorta.
Int J Numer Method Biomed Eng
June 2022
4D Flow Magnetic Resonance Imaging (MRI) is the state-of-the-art technique to comprehensively measure the complex spatio-temporal and multidirectional patterns of blood flow. However, it is subject to artifacts such as noise and aliasing, which due to the 3D and dynamic structure is difficult to detect in clinical practice. In this work, a new mathematical and computational model to determine the quality of 4D Flow MRI is presented.
View Article and Find Full Text PDFPurpose: Three-dimensional (3D) quantification of circulation using a Finite Elements methodology.
Methods: We validate our 3D method using an in-silico arch model, for different mesh resolutions, image resolution and noise levels, and we compared this with a currently used 2D method. Finally, we evaluated the application of our methodology in 4D Flow MRI data of ascending aorta of six healthy volunteers, and six bicuspid aortic valve (BAV) patients, three with right and three with left handed flow, at peak systole.
We addressed comprehensively the performance of Shortest-Path HARP Refinement (SP-HR), SinMod, and DENSEanalysis using 2D slices of synthetic CSPAMM and DENSE images with realistic contrasts obtained from 3D phantoms. The three motion estimation techniques were interrogated under ideal and no-ideal conditions (with MR induced artifacts, noise, and through-plane motion), considering several resolutions and noise levels. Under noisy conditions, and for isotropic pixel sizes of 1.
View Article and Find Full Text PDFWe proposed a novel method called HARP-I, which enhances the estimation of motion from tagged Magnetic Resonance Imaging (MRI). The harmonic phase of the images is unwrapped and treated as noisy measurements of reference coordinates on a deformed domain, obtaining motion with high accuracy using Radial Basis Functions interpolations. Results were compared against Shortest Path HARP Refinement (SP-HR) and Sine-wave Modeling (SinMod), two harmonic image-based techniques for motion estimation from tagged images.
View Article and Find Full Text PDFPurpose: To improve the quality of mean apparent propagator (MAP) reconstruction from a limited number of q-space samples.
Methods: We implement an -regularised MAP (MAPL1) to consider higher order basis functions and to improve the fit without increasing the number of q-space samples. We compare MAPL1 with the least-squares optimization subject to non-negativity (MAP), and the Laplacian-regularized MAP (MAPL).
Purpose: Magnetic resonance elastography (MRE) measures stiffness of soft tissues by analyzing their spatial harmonic response to externally induced shear vibrations. Many MRE methods use inversion-based reconstruction approaches, which invoke first- or second-order derivatives by finite difference operators (first- and second-FDOs) and thus give rise to a biased frequency dispersion of stiffness estimates.
Methods: We here demonstrate analytically, numerically, and experimentally that FDO-based stiffness estimates are affected by (1) noise-related underestimation of values in the range of high spatial wave support, that is, at lower vibration frequencies, and (2) overestimation of values due to wave discretization at low spatial support, that is, at higher vibration frequencies.
Familial hypercholesterolemia (FH) is an autosomal dominant disorder that affects 1 in 250 people. Aortic stiffness, measured by pulse wave velocity (PWV), is an independent predictor for cardiovascular events. Young FH patients are a unique group with early vessel wall disease that may serve to elucidate the determinants of aortic stiffness.
View Article and Find Full Text PDFPurpose: To decompose the 3D wall shear stress (WSS) vector field into its axial (WSS ) and circumferential (WSS ) components using a Laplacian finite element approach.
Methods: We validated our method with in silico experiments involving different geometries and a modified Poiseuille flow. We computed 3D maps of the WSS, WSS , and WSS using 4D flow MRI data obtained from 10 volunteers and 10 patients with bicuspid aortic valve (BAV).
Purpose: We propose a 3D finite-element method for the quantification of vorticity and helicity density from 3D cine phase-contrast (PC) MRI.
Methods: By using a 3D finite-element method, we seamlessly estimate velocity gradients in 3D. The robustness and convergence were analyzed using a combined Poiseuille and Lamb-Ossen equation.
IEEE Trans Med Imaging
October 2016
Velocity measurements from 4D flow MRI are prone to be affected by several imperfections of the MR system. Assuming that blood is incompressible, we propose a novel method for enhancing the velocity field by reducing its divergence. To enhance the velocity data, we added a corrector velocity to each voxel such that the divergence is minimized.
View Article and Find Full Text PDF