Publications by authors named "Joao Pedro Justino de Oliveira Limirio"

Background: Considering the development of new 3D printing technologies that use different printing techniques, further studies must be conducted to evaluate the impact of different printing systems on the mechanical properties of 3D-printed materials. This study aimed to evaluate the mechanical properties of 3D-printed materials for occlusal devices using different 3D printers and printing layer thicknesses.

Material And Methods: Ninety rectangular samples were manufactured and divided into nine groups according to the 3D printer model they were printed on (AnyCubic Mono X, Elegoo Mars 2, or FlashForge Hunter) and the layer thickness (20, 50, or 100 µm) and were subjected to superficial microhardness, flexural resistance, and elasticity modulus tests.

View Article and Find Full Text PDF

Objective: Evaluate the roughness and color stability of different types of resins used to immerse denture bases in various denture cleansers overnight.

Metodology: A total of 150 resin samples were made, which were divided into 3 groups of denture resin (conventional thermally activated, milled and 3D printed) (n= 50) and subdivided into 5 denture cleaners (Distilled water, Corega Tabs, Efferdent, NaOCl 1.0%, Listerine Cool Hint) (n= 10).

View Article and Find Full Text PDF

Statement Of Problem: Prefabricated and custom glass fiber posts have been successfully used to reconstruct endodontically treated teeth. However, the performance of computer-aided design and computer-aided manufacture (CAD-CAM) milled glass fiber posts is unclear.

Purpose: The purpose of this systematic review with meta-analysis was to compare the fracture and bond strength and cement layer thickness of CAD-CAM milled glass fiber posts with prefabricated or custom glass fiber posts.

View Article and Find Full Text PDF

Objectives: This study aimed to assess the influence of translucent monolithic versus bilayered crowns and whether the use of a CoCr base abutments affects the fatigue and fracture resistance of screwed implant-supported single crowns with external connections under mechanical cycling.

Materials And Methods: Fifty specimens were divided into groups: (1) metal-ceramic (MC) crown, (2) veneered zirconia crown (Zr), (3) veneered zirconia crown with a CoCr base abutment (ZrB), (4) monolithic translucent zirconia crown (MZr), and (5) monolithic translucent zirconia crown with a CoCr base abutment (MZrB). Specimens underwent mechanical cycling (5 × 10 cycles; 150 N) evaluating fatigue resistance (number of failures) and those that failed were subsequently subjected to fractographic analyses (stereomicroscope and scanning electron microscope) to evaluate failure location and area, and maximum fracture load was also measured.

View Article and Find Full Text PDF

Objective: The aim was to evaluate the difference in the heat generated between zirconia (Zr) and steel (SS) drills, during implant site preparation.

Material And Methods: This systematic review followed the PRISMA methodology criteria and used the JBI Critical Assessment Guidelines for Quasi-Experimental Studies for quality assessment. The electronic search was conducted by using the PubMed/MEDLINE, Embase, and Cochrane Library databases to January 2023.

View Article and Find Full Text PDF

Purpose: To carry out a systematic review to assess whether low-level laser therapy can improve the quality of life of patients with xerostomia undergoing head and neck radiotherapy.

Methods: A systematic search was performed through Embase, Medline/PubMed, Cochrane, Scopus, Web of Science, nonpeer-reviewed clinicaltrials.gov and LILACS.

View Article and Find Full Text PDF

Statement Of Problem: The consequences of edentulism depend on its complexity and are far-reaching, but limited evidence regarding its association with neurologic health is available.

Purpose: The purpose of this systematic review was to establish the relationship between oral prosthetic rehabilitation and the regional increase in brain activity.

Material And Methods: This systematic review was registered in the International Prospective Register of Systematic Reviews (CRD42021262247), and the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) guideline was followed.

View Article and Find Full Text PDF

Statement Of Problem: Zirconia has become popular for dental implant abutments in the esthetic zone but can damage the implant connection interface. Studies have been conducted to compare zirconia abutments with conventional titanium abutments; however, a consensus or systematic review is lacking.

Purpose: The purpose of this systematic review was to evaluate the performance of abutments made of zirconia and titanium in relation to wear and misfit at the implant-abutment interface.

View Article and Find Full Text PDF

Objective: The objective of this systematic review was to evaluate the efficacy of non-surgical periodontal therapy on rheumatoid arthritis activity.

Material And Methods: Articles published until April 2019 were electronically searched and screened using PubMed / MEDLINE, Scopus, and Cochrane databases according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines (PRISMA). This study was recorded in the international PROSPERO database (CRD42019132205).

View Article and Find Full Text PDF

This is an in silico study aimed to evaluate the biomechanical influence of different implant-abutment interfaces (external hexagon and Morse taper implants), retention systems (cement and screw retained), and restorative crowns (metal-ceramic and monolithic) using 3-dimensional finite element analysis (3D-FEA). Eight 3D models were simulated for the maxillary first molar area using InVesalius, Rhinoceros, and SolidWorks and processed using Femap and NEi Nastran software. Axial and oblique forces of 200 and 100 N, respectively, were applied on the occlusal surface of the prostheses.

View Article and Find Full Text PDF

Statement Of Problem: The development of polymethyl methacrylate (PMMA) computer-aided design and computer-aided manufacturing (CAD-CAM) resin blocks with reported improved mechanical properties has simplified complete denture production. However, whether the objective of improved mechanical properties has been achieved compared with conventional heat-polymerized PMMA is not yet clear.

Purpose: The purpose of this systematic review and meta-analysis was to evaluate the mechanical properties of denture base resins manufactured by conventional heat-polymerization and by CAD-CAM in terms of flexural strength, flexural modulus, and surface roughness.

View Article and Find Full Text PDF

Statement Of Problem: A consensus on whether the use of a complete-denture adhesive provides a clinical benefit remains unclear.

Purpose: The purpose of this systematic review of randomized controlled trials was to evaluate the use of adhesive in complete dentures in terms of retention and stability, patient-reported outcomes measures, and masticatory performance.

Material And Methods: A search was performed in PubMed, Web of Science, and Cochrane Library for articles up to October 2020.

View Article and Find Full Text PDF

Objective: This systematic review aims to assess the efficacy chlorhexidine chip as an adjunctive therapy of scaling and root planning on periodontal disease treatment.

Material And Methods: This study follow the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines (PRISMA) and was registered in the PROSPERO database (CRD42019148221). The search was performed in PubMed/MEDLINE, Scopus, and Cochrane databases until April 2020.

View Article and Find Full Text PDF

Statement Of Problem: A consensus about the effect of crown-to-implant (C/I) ratio in single crowns regarding the implant survival rate and marginal bone loss (MBL) is lacking.

Purpose: The purpose of this systematic review and meta-analysis was to evaluate the influence of C/I ratio in implant-supported single crowns on clinical outcomes.

Material And Methods: The search was made in the PubMed/MEDLINE, Scopus, and the Cochrane Library databases following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses criteria and registered with the International Prospective Register of Systematic Reviews (PROSPERO: CRD42018095711).

View Article and Find Full Text PDF

Statement Of Problem: One-step dental implant surgery with a 1-piece implant has been introduced with the aim of simplifying and increasing the effectiveness of treatment and providing greater comfort for the patient. Whether these goals have been met compared with conventional 2-piece implants remains unclear.

Purpose: The purpose of this systematic review and meta-analysis was to compare the use of 1-piece versus 2-piece implants in terms of marginal bone loss and implant survival rate.

View Article and Find Full Text PDF

The aim of this review was to evaluate the impact of the vomer flap on craniofacial growth in patients with cleft lip and palate. The review was conducted according to the PRISMA checklist and is registered in the International Prospective Register of Systematic Reviews (PROSPERO - CRD42018095714). Two investigators performed the research using the PubMed/MEDLINE, Embase, and Web of Science databases for studies published until November 2018.

View Article and Find Full Text PDF