Int J Prosthodont
November 2023
Purpose: To assess the influence of two preparation techniques on the microleakage, marginal fit, and cement thickness of lithium disilicate veneers.
Materials And Methods: A total of 24 human maxillary central incisors were divided randomly into two groups according to preparation technique (n = 12): minimally invasive preparation with butt-joint design (0.3-mm depth) and a chamfer finish line (group MP); and no preparation (NP).
Patient expectations for rehabilitations of a high esthetic standard as well as the demand for fast but efficient care have provided new work perspectives in dentistry. Dentists also have to choose between conventional and digital workflows. The aim of the present randomized restorative trial was to compare diagnostic waxing (DW) performed conventionally with its digital counterpart and to assess the two approaches from the point of view of both patient and dentist.
View Article and Find Full Text PDFJ Prosthet Dent
March 2023
Statement Of Problem: Various strategies have been proposed to reduce the cement space of foundation restorations for endodontically treated teeth. However, they may add more operative steps, or the dentist must keep different sizes of drills and posts in stock. A 2-piece universal adjustable post system has been developed to overcome this problem, but whether the system has acceptable fatigue survival performance is unclear.
View Article and Find Full Text PDFBackground: This study evaluated the mechanical response of a removable partial denture (RPD) in Kennedy Class II according to being associated or not with implants.
Material And Methods: Four RPDs were manufactured for a Kennedy Class II: CRPD - Conventional RPD, RPD+1M, RPD+2M and RPD+12M, respectively, signifying implant assisted RPDs with the implant installed in the first molar, second molar, and in the first and second molars. The finite element method was used to determine the most damaged support tooth under compressive load (300N, 10s) and strain gauge analysis was used to evaluate the microstrain.
Dent Mater
February 2020
Objectives: This study aimed to evaluate the effect of different materials and undercut on the removal force and stress distribution in the supporting tooth and in the circumferential clasp used in removable partial prosthesis.
Methods: Upper molars prepared for Akers circumferential clasp with retention and opposing arm were modeled, scanned, elaborated with CAD software and the geometries imported in FEA and analyzed. Six different materials were selected for the clasp (Polyamide, Polyoxymethylene, Polyetheretherketone - PEEK, Gold alloy, Titanium and CoCr) and 3 different undercuts (0.
The purpose of this study was to evaluate the influence of surface treatments and thermocycling on the microtensile bond strength (μTBS) of self-adhesive resin cement to human enamel and dentin. Eighty human third molars were selected. The crowns of 40 teeth were transversally sectioned, exposing the mid-coronal dentin.
View Article and Find Full Text PDFThe objective of the study was to evaluate the effect of immediate polishing, after 24 h and after 1 week, on the surface roughness of two micro-hybrid resins (Esthet-X; Opallis) and one nanoparticle resin (Filtek Z350), as well as verifying maintenance of the polish after 1 year, simulated by means of thermal cycling. Forty-three specimens of each material were made and divided into a control group and three experimental groups. The control group specimens received no surface treatment.
View Article and Find Full Text PDF