Publications by authors named "Joanne Goodman"

The ICH M10 guideline establishes global standards for bioanalytical method validation for pharmacokinetic assays, focusing on data reliability and accuracy across studies. A significant component is cross-validation, which should be performed to ensure data comparability when multiple methods or laboratories are involved in a single study or across studies where comparison will be performed. However, ICH M10 does not specify acceptance criteria for cross-validation, creating challenges for the industry because traditionally many laboratories have always utilized acceptance criteria to "pass" or "fail" the study.

View Article and Find Full Text PDF
Article Synopsis
  • Immunogenicity guidance in the biopharmaceutical industry has evolved significantly over the past 20 years due to initial negative reactions with erythropoietin, leading to stringent practices for all biotherapeutic drugs.
  • A recent workshop by the European Bioanalysis Forum highlighted the need to reassess current immunogenicity testing methods, drawing from two decades of experience to suggest more relevant approaches.
  • The proposed new paradigm encourages a context-based assessment of immunogenicity risk, viewing it as a pharmacodynamic biomarker, which aims to streamline testing strategies and better allocate resources for patient benefit.
View Article and Find Full Text PDF

The European Bioanalysis Forum, alongside key industry stakeholders, has been driving the discussions around the implementation of context-of use for biomarker assays to ensure that these assays are validated appropriately depending on their purpose. Insights into understanding why the implementation of context-of-use in assay strategies has also shown that the key stakeholder, or requester for the biomarker data, is responsible for providing the context-of-use statement for all biomarker assay requests. Experts from across the industry haves repeatedly sought a cross-industry recommended format in which the context-of-use statement could be provided.

View Article and Find Full Text PDF

In this report, the European Bioanalysis Forum shares the proposals for harmonized implementation of the ICH M10 guideline on bioanalytical method validation and study sample analysis from the ICH M10 workshop. The focus of the discussions was to understand new, changed or still ambiguous regulatory expectations in the guideline, as identified in feedback from the pre-workshop surveys or during the workshop. The proposals from the workshop aim at stimulating and helping a harmonized implementation of the guideline, and using our community as a sounding board during and after implementation to highlight areas of misalignment and to create a platform for continued sharing with the regulatory authorities in an effort to contribute to industry and regulators developing similar interpretations on guideline expectations.

View Article and Find Full Text PDF

Background Blockade of the lectin-like oxidized low-density lipoprotein receptor-1 (LOX-1) is a potentially attractive mechanism for lowering inflammatory and lipid risk in patients with atherosclerosis. This study aims to assess the safety, tolerability, and target engagement of MEDI6570, a high-affinity monoclonal blocking antibody to LOX-1. Methods and Results This phase 1, first-in-human, placebo-controlled study (NCT03654313) randomized 88 patients with type 2 diabetes to receive single ascending doses (10, 30, 90, 250, or 500 mg) or multiple ascending doses (90, 150, or 250 mg once monthly for 3 months) of MEDI6570 or placebo.

View Article and Find Full Text PDF

Since 2011, the European Bioanalysis Forum has been discussing the topic of context-of-use for biomarker assays, in support of a cross-industry implementation of its principles. The discussions have led to the acknowledgement of the challenges that we face as an industry in implementing these principles. In addition to scientific recommendations, the European Bioanalysis Forum has addressed these challenges by providing recommendations on organizational design, and what works in both sponsor and contract research organizations, to support and enable context-of-use across biomarker strategies.

View Article and Find Full Text PDF

The determination of a tailored anti-drug antibody (ADA) testing strategy is based on the immunogenicity risk assessment to allow a correlation of ADAs with changes to pharmacokinetics, efficacy, and safety. The clinical impact of ADA formation refines the immunogenicity risk assessment and defines appropriate risk mitigation strategies. Health agencies request for high-risk biotherapeutics to extend ADA monitoring for patients that developed an ADA response to the drug until ADAs return to baseline levels.

View Article and Find Full Text PDF

Severe COVID-19 can be associated with a prothrombotic state, increasing risk of morbidity and mortality. The SARS-CoV-2 spike glycoprotein is purported to directly promote platelet activation the S1 subunit and is cleaved from host cells during infection. High plasma concentrations of S1 subunit are associated with disease progression and respiratory failure during severe COVID-19.

View Article and Find Full Text PDF

Biodistribution studies of adenovirus-based vaccines support their clinical development by evaluating their spread and persistence following in vivo administration. AZD1222 (ChAdox1 nCov-19) is a replication-deficient non-human adenovirus-vectored vaccine for coronavirus disease 2019. In this nonclinical study, the biodistribution of AZD1222 was assessed in mice for 29 days following intramuscular injection.

View Article and Find Full Text PDF

Evolving immunogenicity assay performance expectations and a lack of harmonized anti-drug antibody validation testing and reporting tools have resulted in significant time spent by health authorities and sponsors on resolving filing queries. Following debate at the American Association of Pharmaceutical Sciences National Biotechnology Conference, a group was formed to address these gaps. Over the last 3 years, 44 members from 29 organizations (including 5 members from Europe and 10 members from FDA) discussed gaps in understanding immunogenicity assay requirements and have developed harmonization tools for use by industry scientists to facilitate filings to health authorities.

View Article and Find Full Text PDF

During the first half of 2021, and due to the SARS-CoV-2 pandemic preventing in-person meetings, the European Bioanalysis Forum organized four workshops as live interactive online meetings. The themes discussed at the workshops were carefully selected to match the cyberspace dynamics of the meeting format. The first workshop was a training day on challenges related to immunogenicity.

View Article and Find Full Text PDF

AZD1222 (ChAdOx1 nCoV-19) is a COVID-19 vaccine that is not yet licensed for use during pregnancy. To support the inclusion of pregnant and breastfeeding people in AZD1222 clinical studies, a non-clinical developmental and reproductive toxicity study was performed to evaluate its effects on fertility and reproductive processes of female CD-1 mice during the embryofetal development phase, and postnatal outcomes during the littering phase. Immunogenicity assessments were also made in dams, fetuses, and pups.

View Article and Find Full Text PDF

Immunogenicity assays are required to evaluate anti-drug antibody (ADA) responses that can be generated against biotherapeutic modalities. Regulatory guidelines focus on clinical requirements, yet it has become apparent that industry has applied these clinical recommendations for immunogenicity assessment to nonclinical studies in varying degrees. ADAs are an anticipated outcome of dosing a humanized or fully human biotherapeutic into an animal.

View Article and Find Full Text PDF

In 2012, the European Bioanalysis Forum published a recommendation on biomarker method development and the bioanalysis of biomarkers in support of drug development. Since then, there has been significant discussion on how to bring the topic of context of use of biomarker assays to the forefront so that the purpose of the assay, the use of the data and the decisions being made with the data are well defined and clearly understood, not just by the bioanalytical scientist, but across all stakeholders. Therefore, it is imperative that discussions between the bioanalytical laboratory and the end users of the data happen early (and regularly) in the drug development process to enable the right assays to be developed and appropriately validated to generate the correct data and allow suitable decisions to be made.

View Article and Find Full Text PDF

Once released, the ICH M10 Guideline on bioanalytical method validation will become one of the most important milestones in the history of regulated bioanalysis, closing a chapter on intense discussions among the industry and health authorities started in Crystal City in 2001. In this manuscript, the European Bioanalysis Forum community reports back on their feedback on the ICH M10 draft guideline gathered during the public consultation period. The comments given are intended to contribute to a guideline that combines several decades of experience and current scientific vision.

View Article and Find Full Text PDF

It is well accepted that chromatographic assay methods employ singlicate analysis for toxicokinetic and pharmacokinetic analysis. While conversely, it has been the norm for ligand-binding assays to be run in at least duplicate analyses, stemming mainly from concerns over inherent assay variability and reagent quality. Regulatory guidelines and guidance on bioanalytical method validation has, in the most part, recommended multiple replicates for immunoassays and this has led to the industry being comfortable and familiar with duplicate analysis.

View Article and Find Full Text PDF

Combination therapy in Type 2 Diabetes Mellitus is necessary to achieve tight glycaemic control and reduce complication risk. Current treatment plans require patients to take several drugs concomitantly leading to low therapy adherence. This study describes the development and characterisation of a stable parenteral co-formulation of a sodium glucose co-transporter 2 inhibitor (dapagliflozin) and a therapeutic lipidated peptide, using hydroxypropyl-β-cyclodextrin as an enabling excipient.

View Article and Find Full Text PDF

Immunogenicity assays are required to measure antidrug antibodies that are generated against biotherapeutic modalities. As for any ligand-binding assays, critical reagents (CR) play a crucial role in immunogenicity assays, as the robustness and reliability of an assay are defined by the quality and long-term availability of these reagents. The current regulatory guidelines do not provide clear directions on how to implement and verify lot-to-lot changes of CR during an assay life cycle, or the acceptance criteria that should be used when implementing new lots of CR.

View Article and Find Full Text PDF

Critical reagents play a crucial role in ligand-binding assays; the robustness and reliability of an assay is defined by the quality and long-term availability of these reagents. However, neither regulatory guidelines nor relevant scientific papers provide clear directions for set-up, life cycle management and, more importantly, the acceptance criteria required for the testing of the critical reagents for pharmacokinetic, biomarker and immunogenicity assays. The ambiguity from current guidelines can be a challenge for the bioanalytical community.

View Article and Find Full Text PDF

European Bioanalysis Forum Workshop, Lisbon, Portugal, September 2016: At the recent European Bioanalysis Forum Focus Workshop, 'current analysis of immunogenicity: best practices and regulatory hurdles', several important challenges facing the bioanalytical community in relation to immunogenicity assays were discussed through a mixture of presentations and panel sessions. The main areas of focus were the evolving regulatory landscape, challenges of assay interferences from either drug or target, cut-point setting and whether alternative assays can be used to replace neutralizing antibody assays. This workshop report captures discussions and potential solutions and/or recommendations made by the speakers and delegates.

View Article and Find Full Text PDF

The analysis of biomarkers by ligand-binding assays offers significant challenges compared with the bioanalysis of small and large molecule drugs. The presence of endogenous analyte is a commonly cited issue. Also the sourcing and application of appropriate calibration or reference standards can present many issues.

View Article and Find Full Text PDF

Uncontrolled self-association is a major challenge in the exploitation of proteins as therapeutics. Here we describe the development of a structural proteomics approach to identify the amino acids responsible for aberrant self-association of monoclonal antibodies and the design of a variant with reduced aggregation and increased serum persistence in vivo. We show that the human monoclonal antibody, MEDI1912, selected against nerve growth factor binds with picomolar affinity, but undergoes reversible self-association and has a poor pharmacokinetic profile in both rat and cynomolgus monkeys.

View Article and Find Full Text PDF

Niacin has been used for many years in the treatment of dyslipidemia due to its ability to decrease serum levels of triglycerides and low-density lipoprotein cholesterol and to increase levels of high density lipoprotein cholesterol. However, niacin causes severe flushing resulting in poor patient compliance. The discovery of hydroxy-carboxylic acid receptor 2 (HCA2) as a high affinity receptor for niacin has opened avenues to investigate the mechanism of action of niacin, and to potentially discover agonists which maintain the antilipolytic effects of niacin accessed by a decrease in circulating non-esterified fatty acids (NEFA) and thereby perhaps the lipid/lipoprotein effects, but avoid the flushing effects.

View Article and Find Full Text PDF