Publications by authors named "Jizeng Ma"

A site-specific skeleton voxel model for a Chinese adult male was constructed in this paper upon a previous Chinese individual voxel model. The whole skeleton was divided into 19 site-specific bones and bone groups; the mass of various skeleton tissues at each bone site, e.g.

View Article and Find Full Text PDF

A high-resolution whole-body voxel model called CAM representing the Chinese adult male was constructed in this paper based on a previous individual voxel model. There are more than 80 tissues and organs in CAM, including almost all organs required in the ICRP new recommendation. The mass of individual organs has been adjusted to the Chinese reference data.

View Article and Find Full Text PDF

This paper introduces an estimation method for the number of underground coal miners and the annual dose to coal miners in China. It shows that there are about 6 million underground miners at present and the proportion is about 1, 1 and 4 million for national key coal mines, state-owned local coal mines, and township and private-ownership coal mines, respectively. The collective dose is about 1.

View Article and Find Full Text PDF

A voxel phantom of Chinese adult male called CNMAN was constructed from color photographs of the first Chinese visible human data set, for radiation protection purpose. This data set was obtained from a 35-y-old Chinese male cadaver by a medical university in China. The man, 170 cm in height and 65 kg in weight, was dead without any pathological changes.

View Article and Find Full Text PDF

A neutron spectrometry and dosimetry measurement system has been developed based on a different design of the divided regions for a sphere, with three position-sensitive counters. The characteristics of the measurement system have been investigated in the reference radiation fields of Am-Be and (252)Cf sources. When realistic input spectra are used for the unfolding, the overall deviations of the calculated results for four dosimetric quantities are less than +/-10%.

View Article and Find Full Text PDF

The pulse height weighting integration method for measuring H'(0.07) using a plastic scintillator has been developed through Monte Carlo simulations and laboratory tests. In order to design an optimal detector configuration, the parameters of input-window thickness and plastic scintillator thickness were investigated by EGS4 for their influences on the energy response for electrons.

View Article and Find Full Text PDF