Background And Aims: There is significant potential to streamline the clinical pathway for patients undergoing transcatheter aortic valve implantation (TAVI). The purpose of this study was to evaluate the effect of implementing BENCHMARK best practices on the efficiency and safety of TAVI in 28 sites in 7 European countries.
Methods: This was a study of patients with severe symptomatic aortic stenosis (AS) undergoing TAVI with balloon-expandable valves before and after implementation of BENCHMARK best practices.
Background: Use of the current echocardiography-based indications for aortic regurgitation (AR) surgery might result in late valve replacement at the stage of irreversible myocardial damage. Therefore, we aimed to identify simple models combining multiple echocardiography or magnetic resonance imaging (MRI)-derived indices and natriuretic peptides (BNP [brain natriuretic peptide] or NT-proBNP [N-terminnal pro-B type natriuretic peptide]) to predict early disease decompensation in asymptomatic severe AR.
Methods: This prospective and multicenter study included asymptomatic patients with severe AR, preserved left ventricular ejection fraction (>50%), and sinus rhythm.
Introduction: Inherited thrombophilias represent a concerning risk factor due to a proclivity to an aberrant clot formation. However, in patients with left ventricular assist device (LVAD), their impact on bleeding and thrombotic complications remains still poorly understood. The aim of the present study was to evaluate the effect of thrombophilic mutation directed anticoagulation therapy on adverse clinical outcomes in LVAD patients.
View Article and Find Full Text PDFEur Heart J Acute Cardiovasc Care
June 2021
There has been a significant increase in the use of short-term percutaneous ventricular assist devices (pVADs) as acute circulatory support in cardiogenic shock and to provide haemodynamic support during interventional procedures, including high-risk percutaneous coronary interventions. Although frequently considered together, pVADs differ in their haemodynamic effects, management, indications, insertion techniques, and monitoring requirements. This consensus document summarizes the views of an expert panel by the European Association of Percutaneous Cardiovascular Interventions (EAPCI) and the Association for Acute Cardiovascular Care (ACVC) and appraises the value of short-term pVAD.
View Article and Find Full Text PDFThere has been a significant increase in the use of short-term percutaneous ventricular assist devices (pVADs) as acute circulatory support in cardiogenic shock and to provide haemodynamic support during interventional procedures, including high-risk percutaneous coronary interventions. Although frequently considered together, pVADs differ in their haemodynamic effects, management, indications, insertion techniques, and monitoring requirements. This consensus document summarizes the views of an expert panel by the European Association of Percutaneous Cardiovascular Interventions (EAPCI) and the Association for Acute Cardiovascular Care (ACVC) and appraises the value of short-term pVAD.
View Article and Find Full Text PDFAims: There is an increasing awareness of gender-related differences in patients with severe aortic stenosis and their outcomes after surgical aortic valve replacement (SAVR) and transcatheter aortic valve implantation (TAVI).
Methods: Data from the IMPULSE registry were analysed. Patients with severe aortic stenosis (AS) were enrolled between March 2015 and April 2017 and stratified by gender.
Appl Radiat Isot
December 2020
There is a lack of reliable experiments aiming at the prompt fission neutron spectrum of U for energies higher than 10 MeV. The presented experiment performed at the LVR-15 light water reactor aimed at the measurement of very high threshold reactions spectral averaged cross sections such as Mn (n,2n)Mn, Au (n,2n)Au, Au (n,3n)Au, Bi(n,3n)Bi, Bi(n,4n)Bi. Bi(n,3n)Bi and Bi(n,4n)Bi reactions were measured for the first time.
View Article and Find Full Text PDFBackground: Contemporary data regarding the impact of comorbidities on the clinical presentation and management of patients with severe aortic stenosis (AS) are scarce.
Methods: Prospective registry of severe patients with AS across 23 centres in nine European countries.
Results: Of the 2171 patients, chronic kidney disease (CKD 27.
A 19-year-old woman with no previous cardiac history was admitted to the hospital with third-degree atrioventricular block and left ventricular dysfunction. Her condition quickly deteriorated to severe biventricular failure and cardiogenic shock requiring mechanical circulatory support. An endomyocardial biopsy revealed lymphocytic myocarditis with no PCR-detectable viral genomes, with CD8 T-cell predominance and pro-inflammatory macrophage expansion shown by myocardial flow cytometry.
View Article and Find Full Text PDFDetermining the value of new imaging markers to predict aortic valve (AV) surgery in asymptomatic patients with severe aortic regurgitation (AR) in a prospective, observational, multicenter study. Consecutive patients with chronic severe AR were enrolled between 2015-2018. Baseline examination included echocardiography (ECHO) with 2- and 3-dimensional (2D and 3D) vena contracta area (VCA), and magnetic resonance imaging (MRI) with regurgitant volume (RV) and fraction (RF) analyzed in CoreLab.
View Article and Find Full Text PDFBackground Many patients with severe aortic stenosis are referred late with advanced symptoms or inappropriately denied intervention. The objective was to investigate whether a structured communication to referring physicians (facilitated data relay) might improve the rate and timeliness of intervention. Methods and Results A prospective registry of consecutive patients with severe aortic stenosis at 23 centers in 9 European countries with transcatheter as well as surgical aortic valve replacement being available was performed.
View Article and Find Full Text PDFVentricular pressure-volume (PV) analysis is the reference method for the study of cardiac mechanics. Advances in calibration algorithms and measuring techniques brought new perspectives for its application in different research and clinical settings. Simultaneous PV measurement in the heart chambers offers unique insights into mechanical cardiac efficiency.
View Article and Find Full Text PDFObjective: Contemporary data on patients with previously undiagnosed severe aortic stenosis (AS) are scarce. We aimed to address this gap by gathering data from consecutive patients diagnosed with severe AS on echocardiography.
Methods: This was a prospective, multicentre, multinational, registry in 23 tertiary care hospitals across 9 European countries.
For patients with myocardial infarct-related cardiogenic shock (CS), urgent percutaneous coronary intervention is the recommended treatment strategy to limit cardiac and systemic ischemia. However, a specific therapeutic intervention is often missing in non-ischemic CS cases. Though drug treatment with inotropes and/or vasopressors may be required to stabilize the patient initially, their ongoing use is associated with excess mortality.
View Article and Find Full Text PDFThe drive-line to power contemporary ventricular assist devices exiting the skin is associated with infection, and requires a holstered performance of the cardiac pump, which reduces overall quality of life. Attempts to eliminate the drive-line using transcutaneous energy transfer systems have been explored but have not succeeded in viable widespread application. The unique engineering of the coplanar energy transfer system is characterized by 2 large rings utilizing a coil-within-the-coil topology, ensuring robust resonance energy transfer while allowing for a substantial (>6 hours) unholstered circulatory support powered by an implantable battery source.
View Article and Find Full Text PDFBackground: The Heartmate 3 (HM3) is a Conformiteé Européenne mark-approved left ventricular (LV) assist device (LVAD) with fully magnetically levitated rotor and features consisting of a wide range operational speeds, wide flow paths, and artificial pulse. We performed a hemodynamic-echocardiographic speed optimization evaluation in HM3-implanted patients to achieve optimal LV- and right ventricular (RV) shape.
Methods And Results: Sixteen HM3 patients underwent pump speed ramp tests with right heart catheterization.
Cardiac atrophy is the most common complication of prolonged application of the left ventricle (LV) assist device (LVAD) in patients with advanced heart failure (HF). Our aim was to evaluate the course of unloading-induced cardiac atrophy in rats with failing hearts, and to examine if increased isovolumic loading obtained by intraventricular implantation of an especially designed spring expander would attenuate this process. Heterotopic abdominal heart transplantation (HT) was used as a rat model of heart unloading.
View Article and Find Full Text PDFGiant cell myocarditis is known as a rare and frequently fatal type of myocarditis that is usually characterized by progressive congestive heart failure and frequent ventricular arrhythmias. We report a rare case of giant cell myocarditis in a 64-year-old previously healthy woman. The case was complicated by the rapid development of progressive acute heart failure, which required the comprehensive care of our heart team.
View Article and Find Full Text PDFJ Heart Lung Transplant
September 2017
Biomed Pap Med Fac Univ Palacky Olomouc Czech Repub
March 2017
Background: B-type natriuretic peptide (BNP) is a strong predictor of prognosis in chronic heart failure. We aimed to evaluate the clinical correlates and interpretation of BNP monitoring in LVAD out-patient recipients.
Methods: We performed a prospective study in 136 individuals after HeartMate II LVAD implantation.
Background: The HeartMate 3 (HM3) is a Conformiteé Européenne (CE) mark-approved left ventricular assist device (LVAD) with a fully magnetically levitated rotor with features consisting of a wide range of operational speeds, wide flow paths and an artificial pulse. We performed a hemodynamic and echocardiographic evaluation of patients implanted with the HM3 LVAD to assess the speed range for optimal hemodynamic support.
Methods: Sixteen HM3 patients underwent pump speed ramp tests with right heart catheterization (including central venous pressure [CVP], pulmonary artery pressure, pulmonary capillary wedge pressure [PCWP] and blood pressure [BP]) and 3-dimensional echocardiography (3DE).