Publications by authors named "Jiri Lostak"

Aim: To determine the most effective administration of tranexamic acid (TXA) in patients with primary total knee arthroplasty (TKA).

Material And Method: We enrolled a total of 400 patients (154 men and 346 women) in this randomized trial (4 groups, each of 100 patients). The first group (IV1) had a single intravenous dose (15 mg TXA/kg) prior to skin incision.

View Article and Find Full Text PDF

Background: The reliable preoperative identification of patients at a high risk of early reoperations (<2 years after primary surgery) after total knee arthroplasty (TKA) could lead to adjustments of the surgical procedure and counseling, thus lowering the percentage of revision surgeries.

Methods: The unselected cohort consisted of 1885 patients (695 men and 1190 women) who underwent TKA implantation between September 2010 and April 2017 at a single tertiary orthopedic center. Multivariate patient similarity networks were applied to identify patient groups at a high risk of early reoperations based on 25 preoperative parameters.

View Article and Find Full Text PDF

Aim: We assessed various ways of tranexamic acid (TXA) administration on the fibrinolytic system. Blood loss, transfusions, drainage and haematoma were secondary outcomes.

Methods: In this prospective study, we examined 100 patients undergoing primary total knee arthroplasty (TKA) between June and November 2018.

View Article and Find Full Text PDF

Purpose: The purpose of this study was to evaluate the long-term clinical and radiographic outcomes of the Balgrist total hip replacement cup.

Methods: We report the results of a retrospective review of 195 total hip prostheses with Balgrist cup implanted in 178 patients. There were 59 men and 119 women with a mean age at surgery of 52.

View Article and Find Full Text PDF

Background: Ceramic on ceramic (COC) total hip arthroplasty (THA) was developed to reduce wear debris and accordingly, the occurrence of osteolysis and aseptic loosening especially in younger patients. Based on the excellent tribological behavior of current COC bearings and the relatively low biological activity of ceramic particles, significant improvement in survivorship of these implants is expected.

Methods: We used manual search to identify all relevant studies reporting clinical data on COC THAs in PubMed.

View Article and Find Full Text PDF

Background: We studied which factor could predict aseptic loosening in ABG I hip prosthesis with hydroxyapatite coating. Aseptic loosening and periprosthetic osteolysis are believed to be caused, at least in part, by increased polyethylene (PE) wear rate via particle disease. Based on it, increased PE wear rate should be associated with aseptic loosening regardless of the type of implant.

View Article and Find Full Text PDF