Publications by authors named "Jingqiu Liang"

We report a trace gas sensing technique of cavity-enhanced light-induced thermoelastic spectroscopy (CE-LITES) with a Fabry-Pérot (F-P) optical cavity and a high-quality-factor resonant quartz tuning fork (QTF). Pound-Drever-Hall (PDH) locking method is used to lock the laser to the optical cavity. With only a short 9-cm optical cavity (finesse, ∼1283) and a tiny commercially available standard QTF (Q-factor, ∼38910), a CE-LITES sensor for acetylene detection was developed to demonstrate this technique, achieving a minimum detection limit (MDL) of 7.

View Article and Find Full Text PDF

Increasing concerns about air quality due to fossil fuel combustion, especially nitrogen oxides (NO) from marine and diesel engines, necessitate advanced monitoring systems due to the significant health and environmental impacts of nitrogen dioxide (NO). In this study, a gas detection system based on the principle of the non-dispersive infrared (NDIR) technique is proposed. Firstly, the pyroelectric detector was developed by employing an ultra-thin LiTaO (LT) layer as the sensitive element, integrated with nanoscale carbon material prepared by wafer-level graphics technology as the infrared absorption layer.

View Article and Find Full Text PDF

Dissolved gases in the aquatic environment are critical to understanding the population of aquatic organisms and the ocean. Currently, laser absorption techniques based on membrane separation technology have made great strides in dissolved gas detection. However, the prolonged water-gas separation time of permeable membranes remains a key obstacle to the efficiency of dissolved gas analysis.

View Article and Find Full Text PDF

Background: The aim of this study was to evaluate the ability of point-of-care Doppler ultrasound measurements of carotid corrected flow time and its changes induced by volume expansion to predict fluid responsiveness in patients undergoing robot-assisted gynecological surgery.

Methods: In this prospective study, carotid corrected flow time was measured using Doppler images of the common carotid artery before and after volume expansion. The stroke volume index at each time point was recorded using noninvasive cardiac output monitoring with MostCare.

View Article and Find Full Text PDF

We have theoretically investigated the size-dependent optoelectronic properties of InGaP/AlGaInP-based red micro-LEDs through an electro-optical-thermal coupling model. The model considers thermal effects due to current crowding near the electrodes, non-thermal efficiency droop due to electron leakage, and etch defects on the LED sidewall. Sidewall defects reduce the carrier concentration at the light-emitting surface's edge and exacerbate the current crowding effect.

View Article and Find Full Text PDF

We constructed a waveguide-coupled surface plasmon resonance (WCSPR) structure to enhance Raman scattering. In this structure, P-polarized and S-polarized incident lasers can simultaneously coexcite the evanescent field, thereby further enhancing Raman scattering. This configuration is a five-phase Kretschmann resonance setup that consists of a SF10 prism/inner Ag film/SiO film/outer Ag film/water structure.

View Article and Find Full Text PDF

We aimed to compare the ability of carotid corrected flow time assessed by ultrasound and the changes in dynamic preload indices induced by tidal volume challenge predicting fluid responsiveness in patients undergoing robot-assisted laparoscopic gynecological surgery in the modified head-down lithotomy position. This prospective single-center study included patients undergoing robot-assisted laparoscopic surgery in the modified head-down lithotomy position. Carotid Doppler parameters and hemodynamic data, including corrected flow time, pulse pressure variation, stroke volume variation, and stroke volume index at a tidal volume of 6 mL/kg predicted body weight and after increasing the tidal volume to 8 mL/kg predicted body weight (tidal volume challenge), respectively, were measured.

View Article and Find Full Text PDF

Background: We aimed to evaluate the effects of internal jugular vein (IJV) catheterization on intracranial pressure (ICP) and postoperative delirium (POD) during robot-assisted laparoscopic surgery by measuring the optic nerve sheath diameter (ONSD).

Methods: Data from a prospective single-center cohort study, conducted from October 2021 to February 2022, were used. Forty out of 80 patients scheduled for laparoscopic radical hysterectomy or prostatectomy were assigned to the group receiving IJV catheterization (Group I), and the other 40 only received peripheral venous cannulation (Group C) according to clinical need of patients.

View Article and Find Full Text PDF

This paper presents an easy and intact process based on microfluidics static droplet array (SDA) technology to fabricate quantum dot (QD) arrays for full-color micro-LED displays. A minimal sub-pixel size of 20 μm was achieved, and the fluorescence-converted red and green arrays provide good light uniformity of 98.58% and 98.

View Article and Find Full Text PDF

In this paper, a micro-quartz crystal tuning fork (M-QCTF) was first demonstrated for developing a low-cost, highly sensitive quartz tuning fork photodetector array for spectroscopic applications. A gas sensing system based on the M-QCTF photodetector and highly sensitive wavelength modulation spectroscopy was developed. Typically, an atmospheric greenhouse gas methane (CH) molecule was selected as the target analyte for evaluating the M-QCTF and standard commercial QCTF detectivity.

View Article and Find Full Text PDF

Background: The optimal analgesia for video-assisted thoracoscopic surgery (VATS) is still unknown.

Objectives: Our aim was to conduct a network meta-analysis and systematic review to compare the efficacy of different analgesic strategies in VATS.

Study Design: Bayesian network meta-analysis.

View Article and Find Full Text PDF

PDMS (polydimethylsiloxane) is an important soft biocompatible material, which has various applications such as an implantable neural interface, a microfluidic chip, a wearable brain-computer interface, etc. However, the selective removal of the PDMS encapsulation layer is still a big challenge due to its chemical inertness and soft mechanical properties. Here, we use an excimer laser as a cold micro-machining tool for the precise removal of the PDMS encapsulation layer which can expose the electrode sites in an implantable neural interface.

View Article and Find Full Text PDF

Parylene is used as encapsulating material for medical devices due to its excellent biocompatibility and insulativity. Its performance as the insulating polymer of implantable neural interfaces has been studied in electrolyte solutions and in vivo. Biological tissue in vitro, as a potential environment for characterization and application, is convenient to access in the fabrication lab of polymer and neural electrodes, but there has been little study investigating the behaviors of Parylene in the tissue in vitro.

View Article and Find Full Text PDF

Purpose: The neutrophil-to-lymphocyte ratio (NLR) is a useful prognostic marker for various diseases and surgery-induced immunosuppression. While opioids are important in general anesthesia, the association between immediate perioperative immune monitoring and opioid consumption for postoperative analgesia after video-assisted thoracoscopic surgery (VATS) is unknown. We aimed to investigate the effect of analgesic techniques on opioid-induced immune perturbation, and the feasibility of NLR as an indicator of opioid-induced immune changes.

View Article and Find Full Text PDF

PQDs are promising color converters for micro-LED applications. Here we report the micropore filling fabrication of high resolution patterned PQDs with a pixel size of 2 μm using a template with SU8 micropores.

View Article and Find Full Text PDF
Article Synopsis
  • Red and green perovskite quantum dots are used in creating a flexible color-conversion layer that combines with a blue micro-LED for a full-color display.
  • The new display features a pixel pitch of 200 μm and showcases impressive luminous and display performance even when bent.
  • Perovskite quantum dots offer high quantum yield, adjustable wavelengths, and stability, making the color-conversion layer economical and promising for future flexible micro-display technologies.
View Article and Find Full Text PDF

Neural electrical interfaces are important tools for local neural stimulation and recording, which potentially have wide application in the diagnosis and treatment of neural diseases, as well as in the transmission of neural activity for brain-computer interface (BCI) systems. At the same time, magnetic resonance imaging (MRI) is one of the effective and non-invasive techniques for recording whole-brain signals, providing details of brain structures and also activation pattern maps. Simultaneous recording of extracellular neural signals and MRI combines two expressions of the same neural activity and is believed to be of great importance for the understanding of brain function.

View Article and Find Full Text PDF

We have developed a rapid quartz enhanced spectrophone for carbon dioxide (CO) measurement, in which the laser wavelength was tightly locked to a CO absorption line and a custom quartz tuning fork (QTF) operating at 12.5 kHz was employed. The intrinsic QTF oscillation-limited response time, as well as the optimal feedback interval, was experimentally investigated.

View Article and Find Full Text PDF

In this article, 2000 PPI red silicon-based AlGaInP micro-LED arrays were fabricated and investigated. The AlGaInP epilayer was transferred onto the silicon substrate via the In-Ag bonding technique and an epilayer lift-off process. The silicon substrate with a high thermal conductivity could provide satisfactory heat dissipation, leading to micro-LED arrays that had a stable emission spectrum with increasing current density from 20 to 420 A/cm along with a red-shift of the peak position from 624.

View Article and Find Full Text PDF

Background: Despite the popularity of the ultrasound-guided transversus abdominis plane (TAP) block and the diversity of advancing approaches, the extent of injectate spread limits its clinical benefits. This study used three-dimensional computed tomography (3D-CT) imaging and a cold stimulus to evaluate the spread of a local anesthetic injected through the subcostal exterior semilunaris to transversus abdominis plane (SE-TAP) block in healthy volunteers.

Methods: Eight healthy volunteers received a right-side ultrasound-guided SE-TAP block with 25 mL of 0.

View Article and Find Full Text PDF

This paper addresses the problem of inaccurate emissivity presets for multispectral temperature measurements of aero-engine turbine blades and proposes a narrow-band spectral window moving temperature inversion algorithm that does not rely on an assumed emissivity model. As the emissivity of the measured object changes slowly over the narrow spectral window, the temperature corresponding to the normalized spectral radiation intensity for each window in the set temperature range is calculated using the Mahalanobis distance coefficient. The temperature error is less than 1.

View Article and Find Full Text PDF

By combining frequency-division multiplexing and normalized wavelength modulation spectroscopy, a robust remote multi-species sensor was developed and demonstrated for practical hydrocarbon monitoring. Independently modulated laser beams are combined to simultaneously interrogate different gas samples using an open-ended centimeter-size multipass cell. Gas species of interest are demodulated with the second harmonics to enhance sensitivity, and high immunity to laser power variation is achieved by normalizing to the corresponding first harmonics.

View Article and Find Full Text PDF

A compact multigas sensor system based on a single quartz crystal tuning fork (QCTF) and multifrequency synchronous modulation strategy is proposed for trace gas detection. To demonstrate the novel detection technique, three near-infrared continuous-wave (CW) distributed feedback (DFB) diode lasers with center wavelengths of near 1391, 1574, and 1653 nm and a standard 32 kHz QCTF were integrated for simultaneous detection of HO, CO, and CH, respectively. Wavelength modulation spectroscopy with second harmonic detection (WMS-2) was selected for enhancing sensitivity.

View Article and Find Full Text PDF
Article Synopsis
  • This meta-analysis evaluated the success rate and complications of subclavian venous catheterization comparing the supraclavicular (SC) and infraclavicular (IC) approaches, using data from eight randomized controlled trials published before December 30, 2018.
  • The results showed significantly lower failure rates and catheter malposition incidents with the SC approach compared to the IC approach, although there was no difference in the time taken for cannulation or in the rates of artery puncture and pneumothorax.
  • The authors concluded that the SC approach is preferable for subclavian venous catheterization in adults due to its higher success rate and fewer complications.
View Article and Find Full Text PDF