Publications by authors named "Jingjiang Xu"

Optical coherence elastography (OCE) has recently been used to characterize the natural frequencies of delicate tissues (e.g., the human cornea) with sub-micron tissue oscillation magnitudes.

View Article and Find Full Text PDF

Ethnopharmacological Relevance: Liver fibrosis is a critical pathological process in the progression of chronic liver injury, ultimately resulting in cirrhosis, for which currently available therapeutic interventions remain inadequate. Among these, the Qianggan Ruanjian Pill (QGRJP) has emerged as a clinically experienced formula with notable therapeutic efficacy against liver fibrosis. However, the precise underlying mechanisms require further investigation.

View Article and Find Full Text PDF

Polarization-sensitive optical coherence tomography (PS-OCT) is a functional imaging tool for measuring tissue birefringence characteristics. It has been proposed as a potentially non-invasive technique for evaluating skin burns. However, the PS-OCT modality usually suffers from high system complexity and relatively low tissue-specific contrast, which makes assessing the extent of burns in skin tissue difficult.

View Article and Find Full Text PDF

Microliter air-pulse optical coherence elastography (OCE) has recently been proposed for the characterization of soft-tissue biomechanics using transient, sub-nanometer to micrometer-scale natural frequency oscillations. However, previous studies have not been able to provide real-time air-pulse monitoring during OCE natural frequency measurement, which could lead to inaccurate measurement results due to the unknown excitation spectrum. To address this issue, we introduce a dual-channel air-pulse OCE method, with one channel stimulating the sample and the other being simultaneously measured with a pressure sensor.

View Article and Find Full Text PDF

Assessing corneal biomechanics in vivo has long been a challenge in the field of ophthalmology. Despite recent advances in optical coherence tomography (OCT)-based elastography (OCE) methods, controversy remains regarding the effect of intraocular pressure (IOP) on mechanical wave propagation speed in the cornea. This could be attributed to the complexity of corneal biomechanics and the difficulties associated with conducting in vivo corneal shear-wave OCE measurements.

View Article and Find Full Text PDF

Optical coherence tomography angiography (OCTA) in dermatology usually suffers from low image quality due to the highly scattering property of the skin, the complexity of cutaneous vasculature, and limited acquisition time. Deep-learning methods have achieved great success in many applications. However, the deep learning approach to improve dermatological OCTA images has not been investigated due to the requirement of high-performance OCTA systems and difficulty of obtaining high-quality images as ground truth.

View Article and Find Full Text PDF

Clinical measurement of corneal biomechanics can aid in the early diagnosis, progression tracking, and treatment evaluation of ocular diseases. Over the past two decades, interdisciplinary collaborations between investigators in optical engineering, analytical biomechanical modeling, and clinical research has expanded our knowledge of corneal biomechanics. These advances have led to innovations in testing methods (, and recently, in vivo) across multiple spatial and strain scales.

View Article and Find Full Text PDF

Optical coherence tomography (OCT) is a powerful noninvasive imaging technique for detecting microvascular abnormalities. Following optical imaging principles, an OCT image will be blurred in the out-of-focus domain. Digital deconvolution is a commonly used method for image deblurring.

View Article and Find Full Text PDF

(1) Background: To investigate the value of pulsatile trabecular meshwork (TM) motion in predicting the diurnal intraocular pressure (IOP) fluctuation of primary open-angle glaucoma (POAG). (2) Methods: This cross-sectional study recruited 20 normal patients and 30 patients with POAG. Of the POAG group, 20 had stable diurnal IOP and 10 had high IOP fluctuation.

View Article and Find Full Text PDF

Analysis of corneal tissue natural frequency was recently proposed as a biomarker for corneal biomechanics and has been performed using high-resolution optical coherence tomography (OCT)-based elastography (OCE). However, it remains unknown whether natural frequency analysis can resolve local variations in tissue structure. We measured heterogeneous samples to evaluate the correspondence between natural frequency distributions and regional structural variations.

View Article and Find Full Text PDF

Automatic vessel segmentation is a key step of clinical or pre-clinical vessel bio-markers for clinical diagnosis. In previous research, the segmentation architectures are mainly based on Convolutional Neural Networks (CNN). However, due to the limitation of the receipt of field (ROF) of convolution operation, it is difficult to further improve the accuracy of the CNN-based methods.

View Article and Find Full Text PDF
Article Synopsis
  • A study tested optical coherence tomography angiography (OCTA) against traditional capillaroscopy for imaging nailfold microcirculation, which helps diagnose diseases like systemic sclerosis.
  • OCTA provided high-resolution images of the microvasculature, detecting changes under arm compression that capillaroscopy did not, showcasing its potential superiority.
  • Although both methods yielded similar capillary density measurements, OCTA showed significantly larger capillary diameters compared to capillaroscopy, indicating that OCTA could offer more detailed insights into microvascular health.
View Article and Find Full Text PDF

Background: Vascular lesions such as port wine stains (PWS) lead to facial and psychological problems, which require careful and precise treatments. The key point of treating PWS is to selectively destroy the abnormal blood vessels. Hence, the in vivo monitoring of targeted vessels is crucial.

View Article and Find Full Text PDF

Optical coherence tomography (OCT) is a promising non-invasive imaging technique that owns many biomedical applications. In this paper, a deep neural network is proposed for enhancing the spatial resolution of OCTimages. Different from the previous reports, the proposed can recover high-resolutionimages from low-resolutionimages at arbitrary imaging depth.

View Article and Find Full Text PDF

Refractive surgery is recognized as an effective method for myopia treatment, but it can induce night vision disturbances such as glare. We present an eye modeling method for the optical quality assessment in response to the structural changes in the eyes by femto-LASIK surgery. Customized eye models were built from the measurements of 134 right eyes pre- and post-operatively.

View Article and Find Full Text PDF

Purpose: The purpose of this study was to investigate the difference in pulsatile trabecular meshwork (TM) motion between normal and eyes with POAG using phase-sensitive optical coherence tomography (PhS-OCT).

Methods: In this cross-sectional study, eight healthy subjects (16 eyes) and nine patients with POAG (18 eyes) were enrolled. A laboratory-based prototype PhS-OCT system was used to measure pulsatile TM motion.

View Article and Find Full Text PDF

Background: Cervical cancer is the fourth most common cancer in women. Early detection and diagnosis play an important role in secondary prevention of cervical cancer. This study aims to provide more information to develop an effective strategy for the prevention and control of cervical cancer in northern China.

View Article and Find Full Text PDF

Background: Optical coherence tomography angiography (OCTA) is an emerging imaging technique which shows its advantages over visualizing microcirculation with free label. However, its shortcomings in imaging depth limit its development in dermatological field. Nowadays, the newly optical clearing agent (OCA) designed for skin optical imaging demonstrates its potential.

View Article and Find Full Text PDF

We report the development of a 1300 nm swept-source optical coherence tomography (SS-OCT) system specifically designed to perform OCT imaging and optical microangiography (OMAG) in rat eyes in vivo and its use in evaluating the effects of intraocular pressure (IOP) elevation on ocular circulation. The swept laser is operated in single longitude mode with a 90 nm bandwidth centered at 1300 nm and 200 kHz A-line rate, providing remarkable sensitivity fall-off performance along the imaging depth, a larger field of view of 2.5 × 2.

View Article and Find Full Text PDF

Gingiva is the soft tissue that surrounds and protects the teeth. Healthy gingiva provides an effective barrier to periodontal insults to deeper tissue, thus is an important indicator to a patient's periodontal health. Current methods in assessing gingival tissue health, including visual observation and physical examination with probing on the gingiva, are qualitative and subjective.

View Article and Find Full Text PDF

Objectives: To measure and compare microvascular responses within the skin of the upper arm to local stimuli, such as heating or rubbing, through the use of optical coherence tomography angiography (OCTA), and to investigate its impact on blood volume collection.

Materials And Methods: With the use of heat packs or rubbing, local stimulation was applied to the skin of either the left or right upper arm. Data from the stimulated sites were obtained using OCTA comparing pre- and post-stimulation microvascular parameters, such as vessel density, mean vessel diameter, and mean avascular pore size.

View Article and Find Full Text PDF

Background: imaging of the complex cascade of events known to be pivotal elements in the healing of cutaneous wounds is a difficult but essential task. Current techniques are highly invasive, or lack the level of vascular and structural detail required for accurate evaluation, monitoring and treatment. We aimed to use an advanced optical coherence tomography (OCT)-based angiography (OCTA) technique for the non-invasive, high resolution imaging of cutaneous wound healing.

View Article and Find Full Text PDF

Background: In clinical dermatology, the identification of subsurface vascular and structural features known to be associated with numerous cutaneous pathologies remains challenging without the use of invasive diagnostic tools.

Objective: To present an advanced optical coherence tomography angiography (OCTA) method to directly visualize capillary-level vascular and structural features within skin in vivo.

Methods: An advanced OCTA system with a 1310 nm wavelength was used to image the microvascular and structural features of various skin conditions.

View Article and Find Full Text PDF

Background And Objective: Wound healing involves a complex and dynamic biological process in response to tissue injury. Monitoring of the cascade of cellular events is useful for wound management and treatment. The aim of this study is to demonstrate the potential of multifunctional polarization-sensitive optical coherence tomography (PS-OCT) to longitudinally monitor the self-healing process in a murine cutaneous wound model.

View Article and Find Full Text PDF

There is an increasing demand for imaging tools in clinical dermatology that can perform in vivo wide-field morphological and functional examination from surface to deep tissue regions at various skin sites of the human body. The conventional spectral-domain optical coherence tomography-based angiography (SD-OCTA) system is difficult to meet these requirements due to its fundamental limitations of the sensitivity roll-off, imaging range as well as imaging speed. To mitigate these issues, we demonstrate a swept-source OCTA (SS-OCTA) system by employing a swept source based on a vertical cavity surface-emitting laser.

View Article and Find Full Text PDF