Publications by authors named "Jin-Woo Ahn"

Computer modeling and simulation (CM&S) technology is widely used in the medical device industry due to its advantages such as reducing testing time and costs. However, the developer's parameter settings during the modeling and simulation process can have a significant impact on the results. This study developed a test model for the rotational shear strength of dental implants and the constraint force of total knee replacements based on CM&S technology and proposes ideal parameters to ensure reliability.

View Article and Find Full Text PDF

Background: We aimed to improve the tumor localization system using radiofrequency identification (RFID) technology used during laparoscopic surgery for gastric and colorectal cancer. To this end, we developed a detection algorithm and designed improvement for the RFID clip.

Methods: To evaluate the proposed system, a swine-based animal study was conducted, followed by experiments on porcine stomachs and colons using the EASIE-R simulator.

View Article and Find Full Text PDF

In the present study, a NiS@ZnS composite nanostructure was synthesized on a nickel foam substrate by a facile chemical bath deposition (CBD) method. The prepared composites were analyzed by X-ray photoelectron spectroscopy, high resolution transmission electron microscopy, and field emission scanning electron microscopy. The electrochemical performance of the supercapacitor (SC) electrodes was examined by cyclic voltammetry, galvanostatic charge-discharge, and electrochemical impedance spectroscopy.

View Article and Find Full Text PDF

Background And Objectives: During minimally invasive surgery (MIS), it is impossible to directly detect marked clips around tumors via palpation. Therefore, we developed a novel method and device using Radio Frequency IDentification (RFID) technology to detect the position of clips during minimally invasive gastrectomy or colectomy.

Methods: The feasibility of the RFID-based detection system was evaluated in an animal experiment consisting of seven swine.

View Article and Find Full Text PDF

Background: Lung adenocarcinoma is a highly heterogeneous disease with various etiologies, prognoses, and responses to therapy. Although genome-scale characterization of lung adenocarcinoma has been performed, a comprehensive somatic mutation analysis of EGFR/KRAS/ALK-negative lung adenocarcinoma in never-smokers has not been conducted.

Methods: We analyzed whole exome sequencing data from 16 EGFR/KRAS/ALK-negative lung adenocarcinomas and additional 54 tumors in two expansion cohort sets.

View Article and Find Full Text PDF

We investigated the electrical conductivity (sigma) and mechanical property of polyvinylchloride/carbon nanotube composites as a function of the CNT content and processing time during a solid-state process of high speed vibration mixing (HSVM) and high energy ball milling (HEBM). Both processes were suggested to avoid high temperatures, solvents, chemical modification of carbon nanotubes. In this study, the percolation threshold (phi(c)) for electrical conduction is about 1 wt% CNT with a sigma value of 0.

View Article and Find Full Text PDF

A simple structure of spectral fluorescence lifetime imaging microscope (SLIM) is designed with the use of tunable bandpass filter, a kind of Fabry-perot filter that transmission wavelength is varying according to incident angle of light. Feasibility tests of this angle-tuned bandpass filter (ATBF) are performed and it shows high transmission and constant spectral bandwidth (20 nm) with respect to angle of incidence. Furthermore, using two ATBFs in series, spectral bandwidth can be adjustable down to 4 nm.

View Article and Find Full Text PDF