Ultrasound transducer with polarization inversion technique (PIT) can provide dual-frequency feature for tissue harmonic imaging (THI) and frequency compound imaging (FCI). However, in the conventional PIT, the ultrasound intensity is reduced due to the multiple resonance characteristics of the combined piezoelectric element, and it is challenging to handle the thin piezoelectric layer required to make a PIT-based acoustic stack. In this study, an improved PIT using a piezo-composite layer was proposed to compensate for those problems simultaneously.

View Article and Find Full Text PDF

Intravascular ultrasound (IVUS) is a valuable imaging modality for the diagnosis of atherosclerosis. It provides useful clinical information, such as lumen size, vessel wall thickness, and plaque composition, by providing a cross-sectional vascular image. For several decades, IVUS has made remarkable progress in improving the accuracy of diagnosing cardiovascular disease that remains the leading cause of death globally.

View Article and Find Full Text PDF

High intraocular pressure (IOP) is one of the major risk factors for glaucoma, and thus accurate IOP measurements should be performed to diagnose and treat glaucoma early. In this study, a novel technique for measuring the IOP based on acoustic radiation force was proposed, and its potential was experimentally demonstrated. The proposed technique uses the acoustic radiation force to generate axial displacement on the ocular surface while simultaneously measuring the degree of deformation.

View Article and Find Full Text PDF

In ultrasound tissue harmonic imaging (THI), it is preferred that the bandwidth of the array transducer covers at least the fundamental frequency f for transmission and the second harmonic frequency 2f for reception. However, it is challenging to develop an array transducer with a broad bandwidth due to the single resonance characteristics of piezoelectric materials. In this study, we present an improved interleaved array transducer suitable for THI and a dedicated transducer fabrication scheme.

View Article and Find Full Text PDF

Intravascular ultrasound (IVUS) tissue harmonic imaging (THI) is a useful vessel imaging technique that can provide deep penetration depth as well as high spatial and contrast resolution. Typically, a high-frequency IVUS transducer for THI requires a broad bandwidth or dual-frequency bandwidth. However, it is very difficult to make an IVUS transducer with a frequency bandwidth covering from the fundamental frequency to the second harmonic or a dual-peak at the desired frequency.

View Article and Find Full Text PDF

In this study, a phase-canceled backing layer for ultrasound linear array transducer is presented. The proposed backing layer is composed of multiple blocks operated by a phase inversion technique. Inside the proposed backing layer, the phase of the reflected signals can be canceled by adjusting acoustic impedance, piezoelectric layer contact area, and thickness of each block constituting the backing layer.

View Article and Find Full Text PDF

This study evaluated the correlation between the amount of mercury (Hg) compounds in waste phosphor powder from spent UV curing lamps and their leaching characteristics. The appropriate thermal treatment conditions and Hg content in the residue necessary to satisfy the leaching criteria for classification as non-hazardous waste were identified. The decomposition of Hg compounds by thermal treatment was also evaluated by comparing sequential extraction results based on thermal stability and leaching potential of Hg compounds.

View Article and Find Full Text PDF

Elemental mercury (Hg) is predominant constituent of flue gas emitted from coal-fired power plants. Adsorption has been considered the best available technology for removal of Hg from flue gas. However, adsorbent injection increases the amount of ash generated.

View Article and Find Full Text PDF

In most commercial single-element intravascular ultrasound (IVUS) transducers, with 20 MHz to 40 MHz center frequencies, a conductive adhesive is used to bond a micro-sized cable for the signal line to the surface of the transducer aperture (<1 mm × 1 mm size) where ultrasound beam is generated. Therefore, the vibration of the piezoelectric layer is significantly disturbed by the adhesive with the signal line, thereby causing problems, such as reduced sensitivity, shortened penetration depth, and distorted beam profile. This phenomenon becomes more serious as the center frequency of the IVUS transducer is increased, and the aperture size becomes small.

View Article and Find Full Text PDF

It has been well known that the treatment time of high-intensity focused ultrasound (HIFU) surgery can be reduced by expanding the focal area per sonication. Previously, a dual-concentric transducer using phase-inverted signals was proposed to axially extend the focal area, but it has suffered from the deep notch point between two focal lobes. In this paper, we propose the improved HIFU transducer with dual-concentric aperture driven by phase-inverted multifrequency signals based on an inversion layer technique.

View Article and Find Full Text PDF

The hybrid filter (HF) was newly designed and operated with powder activated carbon (PAC) injection to capture mercury and fine particulate matter in the coal power plant. With PAC injection in HF operation, the capture efficiency of elemental mercury was clearly enhanced. When the injection rate of PAC increased from 0 to 20 mg/m, the speciation fraction of elemental mercury significantly decreased from 85.

View Article and Find Full Text PDF

The mercury (Hg) distribution characteristics were investigated in three primary manganese smelting plants in Korea for the assessment of anthropogenic Hg released. Input and output materials were sampled from each process, and Hg concentrations in the samples were analyzed. Among the input materials, the most mercury was found in the manganese ore (83.

View Article and Find Full Text PDF

Background: In the ultrasound B-mode (Brightness-mode) imaging, high side-lobe level reduces contrast to noise ratio (CNR). A linear apodization scheme by using the window function can suppress the side-lobe level while the main-lobe width is increased resulting in degraded lateral resolution. In order to reduce the side-lobe level without sacrificing the main-lobe width, a non-linear apodization method has been suggested.

View Article and Find Full Text PDF