Publications by authors named "Jin Hai Huang"

Objective: At present, there are several guidelines for cancer complicated with VTE, but there is no specific recommendation for the treatment of lung cancer complicated with VTE. Whether is necessary to explore treatment and prevention of VTE in lung cancer.

Background: Venous thromboembolism (VTE) is a common complication of severe lung cancer that can entail many adverse effects for patients.

View Article and Find Full Text PDF

N-Heterocyclic carbenes (NHCs) are efficient Lewis basic catalysts for the umpolung of various polarized unsaturated compounds usually including aldehydes, imines, acyl chlorides and activated esters. NHC catalysis involving electron pair transfer steps has been extensively studied; however, NHC catalysis through single-electron transfer (SET) processes, despite having the potential to achieve chemical transformations of inert chemical bonds and using green reagents, has long been a challenging task in organic synthesis. In parallel, visible-light-induced photocatalysis and photoexcitation have been established as powerful tools to facilitate sustainable organic synthesis, as they enable the generation of various reactive radical intermediates under extremely mild conditions.

View Article and Find Full Text PDF

: To test the performance of the four tonometers in providing IOP measurements that were free of the effects of corneal biomechanics changes caused by refractive surgery.: Four tonometers were employed to provide IOP measurements for 65 participants who accepted Femtosecond laser-assisted LASIK (FS-LASIK). The measurements included GAT-IOP by the Goldmann Applanation Tonometer, DCT-IOP by the Dynamic Contour Tonometer, Goldmann-correlated IOP (ORA-IOPg) and corneal-compensated IOP (ORA-IOPcc) by the Ocular Response Analyzer, and uncorrected IOP (CVS-IOP) and biomechanically corrected IOP (CVS-bIOP) by the Corvis ST.

View Article and Find Full Text PDF

Purpose: To assess the regional changes in corneal shape after femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) in patients with different myopia extents.

Setting: Eye Hospital, Wenzhou Medical University, Wenzhou, China.

Design: Retrospective case series.

View Article and Find Full Text PDF

: To assess the effects of prostaglandin F2α analogues travoprost on the biomechanical behavior of ex-vivo rabbit cornea. : 18 Japanese white rabbits were included in the study. The left eye (treated group, Tr) of each rabbit was preserved for 10 days in storage medium Eusol-C solution with 1:10 travoprost diluent, while the contralateral eye (control group, Co) was preserved in a similar but travoprost-free medium.

View Article and Find Full Text PDF

To develop and validate numerical models of the laser in situ keratomileusis (LASIK) procedure through considering its effect on corneal biomechanical behavior. 3D finite element models of the human eye were developed to simulate LASIK. The models' predictions of post-operative corneal elevation, corneal refractive power with vector decomposition (M, J, J) and refractive error correction (M, J, J) were compared against clinical data obtained for 28 eyes of 28 patients.

View Article and Find Full Text PDF

Purpose: To evaluate the posterior corneal surface differences between non-laser in situ keratomileusis (LASIK) and 10-year post-LASIK myopic eyes.

Methods: The study included 130 eyes from 65 patients, who were treated with myopic LASIK 10 years ago. In addition, 130 eyes from 65 unoperated myopic patients of matching present age and preoperative refraction were divided into control group.

View Article and Find Full Text PDF

Purpose: To analyze the changes in corneal astigmatism as a function of age and develop a novel model to estimate corneal astigmatic change according to age.

Methods: This was a cross-sectional study of right eyes of 3,769 individuals. Total corneal astigmatism, keratometric astigmatism, anterior corneal astigmatism, and posterior corneal astigmatism were measured by a Scheimpflug tomographer.

View Article and Find Full Text PDF

To investigate the effects of diabetes on the biomechanical behavior of cornea in alloxan-induced diabetic rabbits. Diabetes mellitus (DM) was induced in 20 rabbits using alloxan, while another 20 age- and weight-matched non-diabetic rabbits served as controls. Eyes were enucleated after 8 weeks of inducing diabetes and the whole cornea was removed with a 3 mm wide scleral ring and tested under inflation conditions with an internal pressure range of 2.

View Article and Find Full Text PDF

Background/purpose: Staphylococcal enterotoxins (SEs) are soluble extracellular proteins excreted by Staphylococcal bacterial strains, sharing similar structures and virulence. More than 20 genotypes of SEs have been identified, but the toxicity of some new SEs is still unclear.

Methods: In this study, we assessed the toxicity effects of six recombinant SEs (rSEA, rSEO, rSEG, rSEK, rSEU and rSEQ) on Balb/c mice by reverse transcription-polymerase chain reaction (RT-PCR)-based methods and enzyme activity detection.

View Article and Find Full Text PDF

Purpose: To investigate tear film optical quality dynamics by analyzing the postblink temporal changes of objective scatter index (OSI).

Methods: A total of 109 myopic subjects without symptoms of dry eye and 32 myopic subjects diagnosed with dry eye disease were recruited in this cross-sectional study. The right eye for each subject was analyzed.

View Article and Find Full Text PDF

Backgroud: To evaluate the symmetry of corneal biomechanical metrics, measured using an ocular response analyzer (ORA) and self-built corneal inflation test platform, in bilateral rabbit corneas and to investigate their relationship with physical intraocular pressure (IOPp).

Methods: Twenty fresh enucleated eyes from ten rabbits were used for ex vivo whole ocular globe inflation. IOP was increased from 7.

View Article and Find Full Text PDF

Purpose: To evaluate the effectiveness of methods to correct intraocular pressure (IOP) measurements obtained using the Goldmann applanation tonometer (GAT), the ocular response analyzer (ORA), and the Corvis ST tonometer (CVS) for the effects of corneal stiffness parameters: central corneal thickness (CCT), corneal curvature (R), and age in a Chinese population.

Patients And Methods: Data were collected for 99 eyes of 99 participants. Whereas cornea-corrected IOP was obtained directly from ORA (ORA-IOPcc), cornea correction in GAT and CVS was implemented using multiparameter equations developed earlier.

View Article and Find Full Text PDF

Purpose: To improve the reliability of corneal topographic data through the development of a method to estimate the magnitude of misalignment between successive corneal videokeratography (VK) maps and eliminate the effect of misalignment on the repeatability of topography data.

Methods: Anterior and posterior topography maps were recorded twice for 124 healthy eyes of 124 participants using a Pentacam, and the repeatability of measurements was assessed by calculating the differences in elevation between each two sets of data. The repeatability of measurements was re-assessed following the determination of the magnitude of misalignment components (translational displacements: x0, y0 and z0, and rotational displacements: α, β and γ) between each two data sets and using them to modify the second data set within each pair based on an Iterative Closest Point (ICP) algorithm.

View Article and Find Full Text PDF

Background: The neurovascular dysfunction appears to be related to the development of migraines and it could be possible that hypoperfusion might also involve other areas besides brain, including the retina. Numerous studies have analyzed the ability of optical coherence tomography (OCT) to detect retinal nerve fiber layer (RNFL) thickness abnormalities and changes in migraine, but the results have not always been consistent. Therefore, we carried out a meta-analysis to evaluate the RNFL thickness measured with OCT in migraine.

View Article and Find Full Text PDF

The purpose was to assess the suitability of quadratic equations for the accurate representation of corneal topography and consider the effect of translation and rotation fitting on the quality of fit and the curvature results. Topography images were recorded for the anterior and posterior surfaces of 490 corneas of 490 myopic patients using Pentacam. Elevation data were fitted to four shape models, three of which considered translational and/or rotational fitting.

View Article and Find Full Text PDF

The relationship of corneal biomechanical metrics provided by the Ocular Response Analyzer (ORA) and Corvis ST (CVS) with physical intraocular pressure (IOPp) and central corneal thickness (CCT) was evaluated. Thirty fresh enucleated eyes of 30 rabbits were used in ex vivo whole globe inflation experiments. IOPp was measured with a pressure transducer and increased from 7.

View Article and Find Full Text PDF

Purpose: To evaluate the repeatability and reproducibility of a double-pass instrument (OQASII, Visiomereics SL, Spain), which objectively measures overall optical quality of the human eyes.

Methods: The right eye of 119 healthy subjects with best corrected visual acuity of 20/25 or better was included in this prospective, comparative, observational study. Two separate tests with OQASII were conducted sequentially on the same day by two different examiners.

View Article and Find Full Text PDF

Purpose: To investigate the relationship among Lens Opacities Classification System III (LOCS III) grading score, Visual Function Index-14 (VF-14) score, average lens density by the Pentacam Nucleus Staging system, and the objective scatter index measured by the Optical Quality Analysis System in age-related cataract patients.

Design: Prospective, single-center, cross-sectional study.

Methods: Thirty-six subjects (60 eyes) with age-related cataract were recruited.

View Article and Find Full Text PDF

Background: Parkinson disease (PD) is a neurodegenerative process that leads to a selective loss of dopaminergic neurons, mainly in the basal ganglia of the brain. Numerous studies have analyzed the ability of optical coherence tomography (OCT) to detect retinal nerve fiber layer (RNFL) thickness abnormalities and changes in PD, but the results have not always been consistent. Therefore, we carried out a meta-analysis to evaluate the RNFL thickness measured with OCT in PD.

View Article and Find Full Text PDF

Purpose: Numerous studies have evaluated the association between the single-nucleotide polymorphism (SNP) (rs3759223, C→T) in Lumican gene and high myopia risk in the Chinese population. However, the results have been inconsistent. We therefore here examined whether the rs3759223 polymorphism confers high myopia risk by conducting a meta-analysis.

View Article and Find Full Text PDF

We present a 49-year-old woman with nanophthalmos, white cataract, and malignant glaucoma in her left eye. The corrected distance visual acuity (CDVA) in that eye was hand motion, and the intraocular pressure (IOP) fluctuated between 28 mm Hg and 45 mm Hg with antiglaucoma medications. An unsutured sclerectomy combined with zonulectomy, hyaloidectomy, and anterior vitrectomy was performed.

View Article and Find Full Text PDF

Objective: To evaluate the repeatability and agreement of central and peripheral corneal thickness (CT) measurements by high resolution Pentacam rotating Scheimpflug photography and Visante optical coherence tomography (OCT) in unoperated myopic eyes and eyes after Laser In Situ Keratomileusis (LASIK).

Methods: CT at central, thinnest, 1.0 mm and 2.

View Article and Find Full Text PDF

Background: A number of published comparative studies have been conducted to evaluate the efficacy and safety of intraoperative mitomycin C (MMC) in endoscopic dacryocystorhinostomy (EN-DCR). However, results have not always been consistent. Therefore, we carried out a meta-analysis to compare the clinical results of EN-DCR with and without MMC.

View Article and Find Full Text PDF

Objective: To evaluate the precision of Intraocular Lens (IOL) power calculation using a new optical low-coherence reflectometry biometer (Lenstar) and compare the results with those obtained with IOLMaster.

Methods: It was a prospective controlled study. Biometry measurements in 157 eyes of 98 cataract patients were performed by the same examiner with Lenstar and IOLMaster.

View Article and Find Full Text PDF