Publications by authors named "Jim Mechalakos"

Spine stereotactic body radiation therapy frequently involves the delivery of high doses to targets in proximity to the spinal cord; thus, the radiation must be delivered with great spatial accuracy. Monitoring for large shifts in target and cord position that might occur during dose delivery is a challenge for clinics equipped with a conventional C-arm Linac. Treatment must be halted, then imaging and registration must be done to determine whether a significant shift has occurred.

View Article and Find Full Text PDF

Purpose: To describe the details and experience of implementing a MR-only workflow in the clinic for simulation and planning of prostate cancer patients.

Methods: Forty-eight prostate cancer patients from June 2016 - Dec 2016 receiving external beam radiotherapy were scheduled to undergo MR-only simulation. MR images were acquired for contouring (T2w axial, coronal, sagittal), synthetic-CT generation (3D FFE-based) and fiducial identification (3D bFFE-based).

View Article and Find Full Text PDF

To evaluate a commercial synthetic CT (syn-CT) software for use in prostate radiotherapy. Twenty-five prostate patients underwent CT and MR simulation scans in treatment position on a 3T MR scanner. A commercially available MR protocol was used that included a T2w turbo spin-echo sequence for soft-tissue contrast and a dual echo 3D mDIXON fast field echo (FFE) sequence for generating syn-CT.

View Article and Find Full Text PDF

Purpose: To report tumor local progression-free outcomes after treatment with single-dose, image-guided, intensity-modulated radiotherapy and hypofractionated regimens for extracranial metastases from renal cell primary tumors.

Patients And Methods: Between 2004 and 2010, 105 lesions from renal cell carcinoma were treated with either single-dose, image-guided, intensity-modulated radiotherapy to a prescription dose of 18-24 Gy (median, 24) or hypofractionation (three or five fractions) with a prescription dose of 20-30 Gy. The median follow-up was 12 months (range, 1-48).

View Article and Find Full Text PDF

The transfer of radiation therapy data among the various subsystems required for external beam treatments is subject to error. Hence, the establishment and management of a data transfer quality assurance program is strongly recommended. It should cover the QA of data transfers of patient specific treatments, imaging data, manually handled data and historical treatment records.

View Article and Find Full Text PDF