Ambulatory electrocardiogram monitoring devices can be used for 24-72 h to detect arrhythmias. A new device, the ZIO® XT Patch has cardiac monitoring capabilities that can be utilized for up to 14 days. The purpose of this study is to describe duration of ZIO use by age, and to compare its time to arrhythmia detection with the Holter monitor in a pediatric population.
View Article and Find Full Text PDFJ Innov Card Rhythm Manag
September 2018
We present the first known report of a pediatric implantation of the Bluetooth™-enabled Confirm RX™ insertable cardiac monitor (Abbott Laboratories, Chicago, IL, USA) in a 17-year-old patient with unexplained syncopal episodes. This case illustrates the ability to obtain immediate rhythm information from a patient using a Bluetooth™-enabled device following a minimally invasive procedure.
View Article and Find Full Text PDFBackground: Aortic stenosis has been reported to manifest a slow rate of progression in mild disease, with a greater likelihood of progression in patients with moderate-severe disease. The natural history of the Doppler-estimated maximum gradient (DEMG) in patients after balloon aortic valvuloplasty (BAVP) has not previously been studied on a large scale.
Methods And Results: A retrospective review was performed of 360 patients from 1984 to 2012 with aortic stenosis, providing a total of 2059 echocardiograms both before and after BAVP.
Objective: Pseudosyncope can be difficult to distinguish from true syncope. Often, pediatric patients with pseudosyncope undergo multiple tests and referrals before the appropriate diagnosis is reached. The purpose is to describe the utility of the head-up tilt table test to elicit the diagnosis of pseudosyncope in the pediatric population.
View Article and Find Full Text PDFJ Innov Card Rhythm Manag
January 2017
Implantable loop recorders are commonly used to sense arrhythmias. The purpose of this study is to assess the P- and R-wave amplitudes at implantation (I) and follow-up (F) following insertion of the Reveal LINQ™ Insertable Cardiac Monitor (Medtronic, Minneapolis, MN) in an institutional review board-approved, multicenter study performed on pediatric patients younger than 18 years old. Collected data included demographics, presence of congenital heart disease (CHD), P- and R-wave-sensed amplitude at I and F, and the method of implant (i.
View Article and Find Full Text PDFBackground: Ebstein's anomaly is associated with a high incidence of atrial and ventricular arrhythmias. The Cone procedure has become an effective hemodynamic intervention for this malformation. In response to two late postoperative sudden deaths in our early institutional Cone experience, a standardized plan for aggressive rhythm evaluation was instituted, including preoperative electrophysiologic studies (EPS) and intraoperative implantable loop recorder (ILR) placement.
View Article and Find Full Text PDF