Publications by authors named "Jill M Abelseth"

Traditional diabetes therapies have been associated with weight gain, hypoglycemia, and/or high secondary failure rates. Glucagon-like peptide-1 (GLP-1) analog use is associated with a minimal risk of hypoglycemia, a persistent average weight loss of 2 to 3 kg, and sustained efficacy even after 3 years of use. Presently, 3 GLP-1 analogs are commercially available in the United States.

View Article and Find Full Text PDF

Objective: To determine the efficacy of at least 1 year of teriparatide therapy on bone mineral density (BMD), T-scores, and rates of occurrence of fractures in patients with a history of resolved secondary hyperparathyroidism due to vitamin D deficiency and to compare its efficacy with that in patients without a history of resolved secondary hyperparathyroidism.

Methods: In this retrospective study based on a search of electronic medical records, we collected the following data: patient demographics, doses of calcium and vitamin D supplementation, duration of teriparatide treatment, history and treatment of secondary hyperparathyroidism, BMD information, T-scores, and any history of fractures. Paired and unpaired t tests, the Fisher exact test, and the Wilcoxon rank sum test were used for statistical analysis.

View Article and Find Full Text PDF

Purpose: This study compared the accuracy and precision of four value-added glucose meters.

Methods: Finger stick glucose measurements in diabetes patients were performed using the Abbott Diabetes Care (Alameda, CA) Optium, Diagnostic Devices, Inc. (Miami, FL) DDI Prodigy, Home Diagnostics, Inc.

View Article and Find Full Text PDF

Objective: To evaluate the 1-year efficacy and safety of treatment with exenatide in combination with insulin (a use not approved by the US Food and Drug Administration).

Methods: Electronic medical records of 3 private-practice endocrinologists were reviewed to identify patients with type 2 diabetes mellitus (T2DM) receiving insulin who subsequently began exenatide therapy. Patients' baseline hemoglobin A1c (A1C) levels, weights, lipid profiles, blood pressures, and medication utilization were compared with corresponding data obtained after a minimal duration of 12 months.

View Article and Find Full Text PDF

Background: This study compared the accuracy and precision of five blood glucose (BG) meters.

Methods: Diabetes patients undergoing venipuncture for glucose testing were randomized to one of two groups consisting of three meters: FreeStyle Flash (Abbott Diabetes Care, Alameda, CA), Accu-Chek Advantage (Roche Diagnostics Corp., Indianapolis, IN), and Accu-Chek Compact Plus (Roche Diagnostics) or FreeStyle Flash, Ascensia Contour (Bayer Healthcare, Diagnostic Division, Tarrytown, NY), and BD Logic (BD Diabetes Care, Franklin Lake, NJ).

View Article and Find Full Text PDF