Background: Patients with obstructive sleep apnoea (OSA), male sex, obesity, older age or hypertension are prone to hypoxemia during flexible bronchoscopy. This study investigated whether using a high-flow nasal cannula (HFNC) could reduce the incidence of oxygen desaturation during bronchoscopy under deep sedation in patients at risk of hypoxemia.

Methods: A total of 176 patients at risk of hypoxemia who underwent flexible bronchoscopy under deep sedation were randomly assigned to two groups: the HFNC group (humidified oxygen was supplied via a high-flow nasal cannula at a rate of 60 L/min and a concentration of 100%, n = 87) and the facemask group (oxygen was supplied via a tight-fitting facemask at a rate of 6 L/min and a concentration of 100%, n = 89).

View Article and Find Full Text PDF