Significance: Fluorescence sensing within tissue is an effective tool for tissue characterization; however, the modality and geometry of the image acquisition can alter the observed signal.
Aim: We introduce a novel optical fiber-based system capable of measuring two fluorescent contrast agents through 2 cm of tissue with simple passive electronic switching between the excitation light, simultaneously acquiring fluorescence and excitation data. The goal was to quantify indocyanine green (ICG) and protoporphyrin IX (PpIX) within tissue, and the sampling method was compared with wide-field surface imaging to contrast the value of deep sensing versus surface imaging.
To develop a novel Magnetic Resonance Imaging (MRI)-guided Near-Infrared Spectroscopic Tomography (MRg-NIRST) imaging system with an MRI-compatible breast optical interface for breast imaging.
View Article and Find Full Text PDFSignificance: The arterial input function (AIF) plays a crucial role in correcting the time-dependent concentration of the contrast agent within the arterial system, accounting for variations in agent injection parameters (speed, timing, etc.) across patients. Understanding the significance of the AIF can enhance the accuracy of tissue vascular perfusion assessment through indocyanine green-based dynamic contrast-enhanced fluorescence imaging (DCE-FI).
View Article and Find Full Text PDFGuided surgery has demonstrated significant improvements in patient outcomes in some disease processes. Interest in this field has led to substantial growth in the technologies under investigation. Most likely no single technology will prove to be "best," and combinations of macro- and microscale guidance-using radiological imaging navigation, probes (activatable, perfusion, and molecular-targeted; large- and small-molecule), autofluorescence, tissue intrinsic optical properties, bioimpedance, and other characteristics-will offer patients and surgeons the greatest opportunity for high-success/low-morbidity medical interventions.
View Article and Find Full Text PDFPurpose: The aim of this study is to investigate whether near-infrared spectral tomography (NIRST) might serve as a reliable prognostic tool to predict residual cancer burden (RCB) in patients with breast cancer undergoing neoadjuvant chemotherapy (NAC) based upon early treatment response measurements.
Experimental Design: A total of thirty-five patients with breast cancer receiving NAC were included in this study. NIRST imaging was performed at multiple time points, including: before treatment, at end of the first cycle, at the mid-point, and post-NAC treatments.
Significance: Resealing time based loading efficiency of optoporation is the key parameter for drug or gene delivery. This work describes a comparatively simple optical approach to directly measure the cell membrane resealing time of the gold nanoparticle mediated photoporation.
Aim: To establish a membrane potential detection optical system, which can provide a direct measurement of resealing time of the optoporated cells.
Significance: Tissue phantoms that mimic the optical and radiologic properties of human or animal tissue play an important role in the development, characterization, and evaluation of imaging systems. Phantoms that are easily produced and stable for longitudinal studies are highly desirable.
Aim: A new type of long-lasting phantom was developed with commercially available materials and was assessed for fabrication ease, stability, and optical property control.
Following orthopaedic trauma, bone devitalization is a critical determinant of complications such as infection or nonunion. Intraoperative assessment of bone perfusion has thus far been limited. Furthermore, treatment failure for infected fractures is unreasonably high, owing to the propensity of biofilm to form and become entrenched in poorly vascularized bone.
View Article and Find Full Text PDFIndocyanine green (ICG)-based dynamic contrast-enhanced fluorescence imaging (DCE-FI) can objectively assess bone perfusion intraoperatively. However, it is susceptible to motion artifacts due to patient's involuntary respiration during the 4.5-minute DCE-FI data acquisition.
View Article and Find Full Text PDFAccelerating innovation in the space of fluorescence imaging for surgical applications has increased interest in safely and expediently advancing these technologies to clinic through Food and Drug Administration-(FDA-) compliant trials. Conventional metrics for early phase trials include drug safety, tolerability, dosing, and pharmacokinetics. Most procedural imaging technologies rely on administration of an exogenous fluorophore and concurrent use of an imaging system; both of which must receive FDA approval to proceed to clinic.
View Article and Find Full Text PDFPoly(vinylidene fluoride) was grafted with maleic anhydride through reactive extrusion by using diisopropyl benzene peroxide as an initiator and 9-vinyl anthracene as a stabilizer. Effects of various parameters on grafting degree were investigated including the amounts of monomer, initiator and stabilizer. The maximum extent of grafting achieved was 0.
View Article and Find Full Text PDFBone devitalization is believed to be a critical determinant of complications such as infection or nonunion. However, intraoperative assessment of bone devitalization, particularly in open fractures and infections, remains highly subjective resulting in variation in treatment. Optical imaging tools, particularly dynamic contrast-enhanced fluorescence imaging, can provide real-time, intraoperative assessment of bone and soft tissue perfusion, which informs the tissues' ability to heal and fight infection.
View Article and Find Full Text PDFICG-based dynamic contrast-enhanced fluorescence imaging (DCE-FI) and intraoperative DCE- magnetic resonance imaging (MRI) have been carried out nearly simultaneously in three lower extremity bone infection cases to investigate the relationship between these two imaging modalities for assessing bone blood perfusion during open orthopedic surgeries. Time-intensity curves in the corresponding regions of interest of two modalities were derived for comparison. The results demonstrated that ICG-based DCE-FI has higher sensitivity to perfusion changes while DCE-MRI provides superior and supplemental depth-related perfusion information.
View Article and Find Full Text PDFDynamic contrast-enhanced fluorescence imaging (DCE-FI) classification of tissue viability in twelve adult patients undergoing below knee leg amputation is presented. During amputation and with the distal bone exposed, indocyanine green contrast-enhanced images were acquired sequentially during baseline, following transverse osteotomy and following periosteal stripping, offering a uniquely well-controlled fluorescence dataset. An unsupervised classification machine leveraging 21 different spatiotemporal features was trained and evaluated by cross-validation in 3.
View Article and Find Full Text PDFThin-film composite membranes formed by conventional interfacial polymerization generally suffer from the depth heterogeneity of the polyamide layer, i.e., nonuniformly distributed free volume pores, leading to the inefficient permselectivity.
View Article and Find Full Text PDFIntegration of magnetic resonance imaging (MRI) and near-infrared spectral tomography (NIRST) has yielded promising diagnostic performance for breast imaging in the past. This study focused on whether MRI-guided NIRST can quantify hemoglobin concentration using only continuous wave (CW) measurements. Patients were classified into four breast density groups based on their MRIs.
View Article and Find Full Text PDFA rapid and accurate diagnosis of mixed viral infections is important for providing timely therapeutic interventions. The aim of this study was to develop a highly sensitive and specific method for the simultaneous detection of canine distemper virus (CDV), canine parvovirus (CPV) and canine coronavirus (CCV) in mixed infections by combining the high specificity of a dual priming oligonucleotide (DPO) primer system with the high sensitivity of a nanoparticle-assisted PCR (nanoPCR) assay. Under the optimised assay conditions, the multiplex DPO-nanoPCR assay developed using DPO primers was 100-fold more sensitive than the multiplex PCR assay using conventional primers.
View Article and Find Full Text PDFComp Immunol Microbiol Infect Dis
August 2021
To understand the epidemic status of feline bocavirus (FBoV) in Anhui Province, eastern China, FBoV was successfully extracted from fecal samples of domestic cats, and five complete genomes were amplified in this study. Phylogenetic analysis showed that these five strains belong to three different FBoV genotypes. Recombination analysis showed that inter- and intra-genotype recombination events occurred.
View Article and Find Full Text PDFForty two patients with high energy open fractures were involved into the study to investigate whether an indocyanine green (ICG)-based dynamic contrast-enhanced fluorescence imaging (DCE-FI) can be used to objectively assess bone perfusion and guide surgical debridement. For each patient, fluorescence images were recorded after 0.1 mg/kg of ICG was administered intravenously.
View Article and Find Full Text PDFFeline bocavirus 1 (FBoV-1) may be associated with diarrhea in cats. In this study, a SYBR Green I-based quantitative polymerase chain reaction (qPCR) assay was established to detect FBoV-1. The melting curve showed a single melting peak at 83.
View Article and Find Full Text PDFA duplex SYBR Green I-based real-time PCR assay was established for the simultaneous detection of canine kobuvirus (CaKoV) and canine astrovirus (CaAstV). This assay can easily distinguish the two viruses according to their different melting temperatures (Tm) of 80 °C for CaKoV and 86.5 °C for CaAstV; other canine enteroviruses used as controls showed no specific melting peaks.
View Article and Find Full Text PDFIn this study, an indocyanine green (ICG)-based dynamic contrast- enhanced fluorescence imaging (DCE-FI) technique was evaluated as a method to provide objective real-time data on bone perfusion using a porcine osteotomy model. DCE-FI with sequentially increasing injury to osseous blood supply was performed in 12 porcine tibias. There were measurable, reproducible and predictable changes to DCE-FI data across each condition have been observed on simple kinetic curve-derived variables as well variables derived from a novel bone-specific kinetic model.
View Article and Find Full Text PDFSignificance: The necessity to use exogenous probes for optical oxygen measurements in radiotherapy poses challenges for clinical applications. Options for implantable probe biotechnology need to be improved to alleviate toxicity concerns in human use and facilitate translation to clinical trial use.
Aim: To develop an implantable oxygen sensor containing a phosphorescent oxygen probe such that the overall administered dose of the probe would be below the Federal Drug Administration (FDA)-prescribed microdose level, and the sensor would provide local high-intensity signal for longitudinal measurements of tissue pO2.
Cherenkov light induced from megavolt (MV) X-rays during external beam radiotherapy serves as an internal light source to excite phosphors or fluorophores within biological tissues for molecular imaging. The broad spectrum of Cherenkov light leads to significant spectral overlap with any luminescence emission and, to overcome this problem, a single pixel hyperspectral imaging methodology was demonstrated here by coupling the detection with light sheet scanning and filtered back projection reconstruction of hyperspectral images. Thin scanned sheets of MV X-rays produce Cherenkov light to illuminate the planes deep within the tissue-simulating media.
View Article and Find Full Text PDF