It is well-established that complete expansion and proper apposition to the vessel wall of flow-diverter stents are critical for optimizing endovascular aneurysm outcomes by using flow diversion techniques. We aimed to evaluate the clinical value of high-resolution cone-beam CT (HR-CBCT) upon flow-diverter stent implantation in intracranial aneurysms. In this study, we retrospectively analyzed the clinical data of eighty-one patients (101 intracranial aneurysms) who underwent flow-diverter stent implantation (Pipeline™ or Tubridge™).
View Article and Find Full Text PDFBackground: In recent years, among patients with chronic cerebral artery occlusion, recanalization can be achieved by an endovascular operation. However, complications and restenosis rates remain high.
Objective: To evaluate the utility of high-resolution C-arm CT (Dyna micro-CT) for stent placement in patients with chronic cerebral artery occlusion.
Background: There are few reports of a fractured esophageal self-expanding metallic stent (SEMS) and the lasso retrieval technique, forming a guidewire loop by directing the guidewire back up the external stent for retrieval.
Case Summary: A 74-year-old man complained of dysphagia approximately 6 mo after radical resection of esophageal cancer. Benign anastomotic stenosis was diagnosed, and a 20 mm in diameter and 60 mm in length esophageal covered SEMS was inserted after repeated balloon dilatation.
Background: The present study aimed to compare the clinical results and pathological diagnostic quality of percutaneous transhepatic cholangiobiopsy for biliary obstruction using biopsy forceps (BFs) of varying diameter.
Methods: A total of 57 patients with obstructive jaundice who underwent percutaneous transhepatic cholangiobiopsy and drainage with 1 of 2 BFs diameters (6.0-mm BFs, n=30; 4.
Percutaneous balloon dilatation for benign biliary-enteric anastomosis stricture has been the most widely used alternative to endoscopic treatment. However, patency results from the precedent literature are inconsistent.The objective of this study was to evaluate the safety and feasibility of repeated balloon dilatation with long-term biliary drainage for the treatment of benign biliary-enteric anastomosis strictures.
View Article and Find Full Text PDFCan J Gastroenterol Hepatol
May 2021
Unlabelled: . Upper gastrointestinal bleeding is a threat to patients with gastric varices (GVs). Previous studies have concluded that both transjugular intrahepatic portosystemic shunt (TIPS) and balloon-occluded retrograde transvenous obliteration (BRTO) are effective treatments for patients with GV.
View Article and Find Full Text PDFWe retrospectively analyzed 17 patients with esophageal stent who underwent cervical esophageal and/or hypopharyngeal stenosis after total laryngectomy (TL) from January 2014 to January 2018. The success rate of stent implantation was 100%. Dysphagia in 16 patients improved to class 0 or 1 (16/17, 94.
View Article and Find Full Text PDFBackground: The objective of this study was to investigate the plasma pharmacokinetic profiles, intratumoral concentration and tissue distribution of arsenic trioxide (ATO) by drug-eluting beads (DEB)-transcatheter arterial chemoembolization (TACE) compared with conventional TACE (cTACE) in a rabbit liver tumor model.
Methods: Sixty-four rabbits with VX2 liver tumor were established and randomly assigned to four groups equally. The calliSpheres microspheres (CSM)-ATO group received DEB-TACE treatment using ATO-loaded CSM; the cTACE-ATO group received cTACE treatment using ATO mixed with lipiodol; the CSM-normal control (NC) group received DEB-TACE treatment using blank CSM; the TAE-lipiodol group received cTACE treatment using saline mixed with lipiodol.
Background: Takayasu arteritis is a rare but intractable chronic disease in young female patients. Percutaneous transluminal angioplasty of the involved renal arteries has been reported; however, few studies have reported the use of drug coated balloon angioplasty in the treatment of Takayasu arteritis. We aimed to demonstrate five young female patients who presented with a history of hypertension due to Takayasu arteritis.
View Article and Find Full Text PDFIncreasing evidences suggested that insufficient radiofrequency ablation (RFA) can paradoxically promote tumor invasion and metastatic processes, while the effects of moderate hyperthermia on cancer progression are not well illustrated. Our present study confirmed moderate hyperthermia treatment can promote the proliferation, migration and invasion of hepatocellular carcinoma (HCC) cells, which was evidenced by the results that moderate hyperthermia induced up regulation of proliferating cell nuclear antigen (PCNA) and matrix metalloproteinase-2 (MMP-2). Cellular studies indicated that moderate hyperthermia treatment can increase the mRNA and protein expression of IL-6 and IL-10, while not IL-2, IL-4, IL-8, IL-22, VEGF, TGF-β, or TNF-α, in HCC cells.
View Article and Find Full Text PDFObjectives: To assess the clinical role of flat-panel cone beam CT (CBCT) in performing percutaneous needle biopsy (PNB) of bone lesions. Flat-panel cone beam CT systems have been used as a guidance tool for performing percutaneous biopsy. Real-time fluoroscopy and virtual navigation systems help simplify needle path planning and shorten procedure times.
View Article and Find Full Text PDFBackground: Cholangiocarcinoma (CCA) is highly resistant to chemo-therapy, including 5-fluorouracil (5-FU) treatment. MicroRNAs are endogenous and short non-coding RNAs that can regulate multiple genes expression. Many microRNAs have shown functional roles in the chemo-resistance of tumors.
View Article and Find Full Text PDFWe describe the case of a patient with Budd-Chiari syndrome who presented with an unusual membranous obstruction of the inferior vena cava complicated by massive portal vein thrombosis (PVT). The patient underwent percutaneous transluminal balloon angioplasty through the right groin and was prescribed oral warfarin for 6 months. Treatment resulted in the complete disappearance of the PVT.
View Article and Find Full Text PDFQuercetin is a potent cancer therapeutic agent and dietary antioxidant present in fruit and vegetables. Quercetin prevents tumor proliferation by inducing cell cycle arrest and is a well known cancer therapeutic agent and autophagy mediator. Recent studies showed that drug delivery by nanoparticles have enhanced efficacy with reduced side effects.
View Article and Find Full Text PDFBackground Metastasis to the adrenal glands is frequent in patients with various cancers and adrenal gland biopsy is routinely performed using ultrasound or computed tomographic (CT) guidance. However, this method is technically challenging, especially in the case of small masses. Purpose To determine whether the new real-time stereotactic needle guidance technique C-arm cone-beam CT (CBCT) allows safe and accurate biopsy of adrenal gland masses, especially those in hard-to-reach anatomical locations.
View Article and Find Full Text PDFObjective: To determine the safety and feasibility of combined-type integrated Y-shaped self-expanding covered metallic stents to treat gastrotracheal fistulas (GTFs) and gastrobronchial fistulas (GBFs).
Methods: We retrospectively reviewed the data of 10 patients with postoperative GTFs or GBFs. Depending on the size and location of the fistula and the airway diameter, we custom-designed 2 or 3 stents for each patient.
Background: Anastomotic stenosis is an infrequent but life-threatening complication after gastrojejunostomy (Billroth II). Tubular or single tubular stents have limited efficacy due to the particular anatomy.
Purpose: To assess the feasibility of a Y-shaped, fully-coated, self-expandable, metallic stent (SEMS) for anastomotic stenosis after gastrojejunostomy (Billroth II).
Background: Obstructive jaundice (OJ) is insensitive to radiation and chemotherapy, and a pathologic diagnosis is difficult to make clinically. Percutaneous transhepatic cholangiobiopsy (PTCB) is simple to perform and minimally invasive, and clinical practice has shown it to be an accurate and reliable new method for bile duct histopathologic diagnosis.
Purpose: To investigate the value of PTCB for pathologic diagnosis of causes of OJ.
Background: To explored the value of 3D C-arm CT (CACT) guidance system in performing radiofrequency ablation (RFA) following transarterial chemoembolizationon (TACE) for hepatocellular carcinomas.
Materials And Methods: RFA of hepatocellular carcinomas (HCC) were performed on 15 patients (21 lesions) with the assistance of CACT guidance system. Technical success, procedure time, complications and patient radiation exposure were investigated.
Background: Nowadays, flat detector (FD) equipped angiographic C-arm computed tomography (CACT) systems can be used to acquire CT-like cross-sectional images directly within the interventional suite. The CACT systems offer real time visualization of transthoracic needle biopsy (TNB) procedure and more flexibility in the orientation of the detector system around the patient compared to traditional CT systems.
Purpose: To evaluate the value of a flat detector C-arm CT-guidance system in performing percutaneous transthoracic needle biopsy (PTNB) for small (≤3 cm) pulmonary lesions in clinical practice.
Objectives: To determine the safety and feasibility of intraductal radiofrequency ablation (RFA) followed by locoregional tumor treatments in patients with non-resectable malignant biliary obstruction and stent re-occlusion.
Methods: Fourteen patients with malignant biliary obstruction and blocked metal stents were studied retrospectively. All had intraductal RFA followed by locoregional tumor treatments and were monitored clinically and radiologically.
Background The rich neovascularization of renal angiomyolipoma (AML) has a tendency for spontaneous rupture with subsequent hemorrhage. Nephrectomy or nephron-sparing surgery has rarely been used as a primary treatment in urgent situations. Purpose To evaluate the safety and long-term outcomes for patients treated by urgent transcatheter arterial embolization (TAE) for spontaneous ruptured renal AML with severe hemorrhage.
View Article and Find Full Text PDFAim: To determine the value of computed tomographic angiography (CTA) for diagnosis and therapeutic planning in lower gastrointestinal (GI) bleeding.
Methods: Sixty-three consecutive patients with acute lower GI bleeding underwent CTA before endovascular or surgical treatment. CTA was used to determine whether the lower GI bleeding was suitable for endovascular treatment, surgical resection, or conservative treatment in each patient.
Purpose: To determine the safety and feasibility of percutaneous transhepatic cholangiography (PTC) and intraductal radiofrequency (RF) ablation combined with biliary stent placement for malignant biliary obstruction.
Materials And Methods: Data from patients with unresectable malignant biliary obstruction who underwent PTC, intraductal RF ablation, and biliary stent placement (n = 12) or PTC and biliary stent placement only (control group; n = 14) were reviewed. Postoperative complications, jaundice remission, and stent patency were assessed.
Background: To analyze our experience with clinical features and endovascular treatment of visceral artery pseudoaneurysms (VAPAs).
Methods: We performed endovascular treatments on 52 patients (34 men and 18 women) affected by VAPA. These cases were pseudoaneurysms of the celiac axis, superior mesenteric artery, and their branches.