IEEE Trans Ultrason Ferroelectr Freq Control
January 2024
High image resolution is desired in wave-related areas such as ultrasound, acoustics, optics, and electromagnetics. However, the spatial resolution of an imaging system is limited by the spatial frequency of the point spread function (PSF) of the system due to diffraction. In this article, the PSF is modulated in amplitude, phase, or both to increase the spatial frequency to reconstruct super-resolution images of objects or wave sources/fields, where the modulator can be a focused shear wave produced remotely by, for example, a radiation force from a focused Bessel beam or X-wave, or can be a small particle manipulated remotely by a radiation-force (such as acoustic and optical tweezers) or electrical and magnetic forces.
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
November 2023
An ultrasound concave 2-D ring array transducer was designed for applications in visual stimulation of the retina with a long-term goal to restore vision in individuals with intact neurons but suffering blindness due to retinopathies. The array was synthesized and has a frequency of 20 MHz (0.075-mm wavelengths in water), 18-mm focal length (the curvature of the concave array), 1004 elements (with a pitch of 4.
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
June 2021
Among tracking techniques applied in the 3-D freehand ultrasound (US), the camera-based tracking method is relatively mature and reliable. However, constrained by manufactured marker rigid bodies, the US probe is usually limited to operate within a narrow rotational range before occlusion issues affect accurate and robust tracking performance. Thus, this study proposed a hemispherical marker rigid body to hold passive noncoplanar markers so that the markers could be identified by the camera, mitigating self-occlusion.
View Article and Find Full Text PDFHydroquinone (HQ) is one of the major deleterious metabolites of benzene in the human body, which has been implicated to cause various human diseases. In order to fabricate a feasible sensor for the accurate detection of HQ, we attempted to electrochemically modify a piece of common 2B pencil lead (PL) with the conductive poly(3,4-ethylenedioxythiophene) or PEDOT film to construct a PEDOT/PL electrode. We then examined the performance of PEDOT/PL in the detection of hydroquinone with different voltammetry methods.
View Article and Find Full Text PDFDopamine (DA) is an important neurotransmitter responsible for the functions and activities of multiple systems in human. Electrochemical detection of DA has the advantages of fast analysis and cost-effectiveness, while a regular electrode probe is restricted to laboratory use because the probe size is too large to be suitable for an in vivo or in vitro analysis. In this study, we have developed porphyrin-based metal organic framework (MOF525) and poly(3,4-ethylenedioxythiophene) (PEDOT)-based composites to modify microelectrode for DA detection.
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
February 2020
The point spread function (PSF) is often analyzed to determine the image quality of an ultrasound system. The formation of PSF is determined by practical factors, such as transducer aperture, element directivity, apodization, pitch, imaging position, and steering angle. Conventional numerical simulations provide an iterative approach to examine those factors' effects but cannot explain the inherent mechanism of PSF formation.
View Article and Find Full Text PDFThe goal of this paper is to quantitatively study effects of phase aberration and noise on high-frame-rate (HFR) imaging using a set of traditional and new parameters. These parameters include the traditional -6-dB lateral resolution, and new parameters called the energy ratio (ER) and the sidelobe ratio (SR). ER is the ratio between the total energy of sidelobe and the total energy of mainlobe of a point spread function (PSF) of an imaging system.
View Article and Find Full Text PDFPrevious solutions for spatial impulse responses of rectangular planar transducers require either approximations or complex geometrical considerations. This paper describes a new, simplified and exact solution using only trigonometric functions and simple set operations. This solution, which can be numerically implemented with a straightforward algorithm, is an exact implementation of the Rayleigh integral without any far field or paraxial approximation.
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
July 2007
Based on the high frame rate (HFR) imaging method developed in our lab, an extended high frame rate imaging method with various transmission schemes was developed recently. In this method, multiple, limited-diffraction array beams or steered plane wave transmissions are used to increase image resolution and field of view as well as to reduce sidelobes. Furthermore, the multiple, limited-diffraction array beam transmissions can be approximated with square-wave aperture weightings, allowing one or two transmitters to be used with a multielement array transducer to simplify imaging systems.
View Article and Find Full Text PDFUltrason Imaging
April 2007
Based on the high frame rate (HFR) imaging theories, an extended HFR imaging method has been developed recently in our lab where multiple limited-diffraction array beams or steered plane waves are used in transmissions to reconstruct a high quality image of an equivalent dynamic focusing in both transmissions and receptions. The method has the potential to simplify imaging systems because the fast Fourier transform and square-wave aperture weightings can be used. The method is also flexible in using different numbers of transmissions for a continuous trade-off between image quality and frame rate.
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
October 2006
A general-purpose high frame rate (HFR) medical imaging system has been developed. This system has 128 independent linear transmitters, each of which is capable of producing an arbitrary broadband (about 0.05-10 MHz) waveform of up to +/- 144 V peak voltage on a 75-ohm resistive load using a 12-bit/40-MHz digital-to-analog converter.
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
May 2006
Fast three-dimensional (3-D) ultrasound imaging is a technical challenge. Previously, a high-frame rate (HFR) imaging theory was developed in which a pulsed plane wave was used in transmission, and limited-diffraction array beam weightings were applied to received echo signals to produce a spatial Fourier transform of object function for 3-D image reconstruction. In this paper, the theory is extended to include explicitly various transmission schemes such as multiple limited-diffraction array beams and steered plane waves.
View Article and Find Full Text PDFUltrason Imaging
October 2005
A method is developed for calculating fields produced with a two-dimensional (2D) array transducer. This method decomposes an arbitrary 2D aperture weighting function into a set of limited diffraction array beams. Using the analytical expressions of limited diffraction beams, arbitrary continuous wave (cw) or pulse wave (pw) fields of 2D arrays can be obtained with a simple superposition of these beams.
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
September 2002
A 1-D Fourier-Bessel series method for computing and tuning the linear lossless field of flat continuous wave (CW) annular arrays is given and discussed with both numerical simulation and experimental verification. The technique provides a new method for modelling and manipulating the propagated field by linking the quantized surface pressure profile to a set of limited diffraction Bessel beams propagating into the medium. In the limit, these become a known set of nondiffracting Bessel beams satisfying the lossless linear wave equation, which allow us to derive a linear matrix formulation for the field in terms of the ring pressures on the transducer surface.
View Article and Find Full Text PDF