Background: Distal radius fractures accompanied by the volar margin of the lunate fossa (VMLF) lesions are often overlooked or inadequately reduced in clinical practice.
Aim: To investigate the impact of VMLF fragment in distal radius fractures on the stability and function of the wrist joint.
Methods: This was a retrospective study of patients with distal radius fractures who underwent surgical treatment between January 2013 and December 2017.
Neural Regen Res
September 2020
Current animal models of nerve root compression due to lumbar disc herniation only assess the mechanical compression of nerve roots and the inflammatory response. Moreover, the pressure applied in these models is static, meaning that the nerve root cannot be dynamically compressed. This is very different from the pathogenesis of lumbar disc herniation.
View Article and Find Full Text PDFAfter peripheral nerve injury, intraperitoneal injection of folic acid improves axon quantity, increases axon density and improves electromyography results. However, the mechanisms for this remain unclear. This study explored whether folic acid promotes peripheral nerve injury repair by affecting Schwann cell function.
View Article and Find Full Text PDFBackground: Small animal models that can mimic degenerative disc disease (DDD) are commonly used to examine DDD progression. However, assessments such as histological studies and macroscopic measurements do not allow for longitudinal studies because they can only be completed after the animal is sacrificed. Dynamic contrast-enhanced MRI (DCE-MRI) may provide a reliable, non-invasive in vivo method for detecting the progression.
View Article and Find Full Text PDFTransforaminal lumbar interbody fusion (TLIF) is an important surgical option for the treatment of back pain and radiculopathy. The minimally invasive TLIF (MI-TLIF) technique is increasingly used to achieve neural element decompression, restoration of segmental alignment and lordosis, and bony fusion. This article reviews the surgical technique, outcomes, and complications in a series of 144 consecutive 1- and 2-level MI-TLIFs in comparison with an institutional control group of 54 open traditional TLIF procedures with a mean of 46 months' follow-up.
View Article and Find Full Text PDFObjectives: To study the stress distribution of the adjacent different grades of disc degeneration underwenting unilateral laminectomy and discectomy surgery using non-linear finite element analysis.
Methods: Based on the lumbar CT scans, the finite element model (FEM) of lumbar spinal segment (L3-L5) was established. According to L3-L4 intervertebral disc degeneration, different grades of disc degeneration (healthy, mild, moderate and severe) models were established and unilateral laminectomy and discectomy surgery were also established.
Background: Adjacent segment degeneration (ASD) following lumbar fusion has been well documented in recent years. However, the pathogenesis of ASD is not clear. To investigate this issue, we established a finite element model of segments L2-L5, simulated a single-segment posterior fixation in L3-L4 and investigated the stress variation and the effects of the instrumented lumbar posterior fixation on adjacent levels.
View Article and Find Full Text PDFObjective: To explore the best surgical fusion level for adolescent idiopathic scoliosis (AIS) of PUMC II d(2) with finite element model (FEM).
Methods: FEM (T(5)-S) of PUMC II d(2) idiopathic scoliosis was used to simulate upper thoracic curve, lower lumbar curve and double curve fusion manners. The pedicle of concave vertebral arch received 50, 100 and 150 N load respectively.
Zhonghua Yi Xue Za Zhi
January 2010
Objective: To investigate the association between Trp2 allele polymorphism with degenerative disc disease (DDD) in a Chinese Han population.
Methods: A total of 125 DDD patients (58 males and 67 females, 51.8 +/- 7.
Zhongguo Yi Xue Ke Xue Yuan Xue Bao
August 2009
Objective: To investigate the mechanical changes of the degenerated lumbar disc with finite element analysis.
Methods: A three dimensional finite element model of a human lumbar spine at the L3-L4 disc was established by the software MIMICS and ABAQUS based on computer tomography images. Degeneration was modeled by changes in geometry and material properties.
Objective: To study the relationship between the fulcrum bending flexibility (FBF) and correction rate (CR) of adult idiopathic scoliosis, and to explore the ability of FBF to assess the correction effect in relation to fulcrum bending flexibility.
Methods: 69 patients with adult idiopathic scoliosis with structural curves at thoracic or lumbarthoracic segments, 16 males and 53 females, aged 26.5 (19 - 53) were treated by pedicle screws instrumentation.
Objective: To build a 3D finite element model of whole lumbar spine and verify its efficiency and analyze the biomechanical change of L3-4 motion segment.
Methods: L1-L5 segment data were obtained from computed tomography (CT) scans of the lumbar spine of a 40-year-old man with no abnormal findings. A three-dimensional finite element model of the human whole lumbar spine was built in the Mimics and the ABAQUS software.
Zhonghua Yi Xue Za Zhi
January 2009
Objective: To evaluate the mechanical response of L3-L4 segment after posterior interfixation with a transpedicle screw system.
Methods: Spiral CT machine was used to conduct continuous parallel scan on the L3-L4 section of a 40-year-old healthy male Chinese. The image data thus obtained were introduced into MIMICS software to reconstruct the 2-D data into volume data and obtain 3-D models of every element.
Zhonghua Yi Xue Za Zhi
June 2008
Objective: To analyze and compare the Imaging findings of adult idiopathic scoliosis and degenerative scoliosis which were the most common adult scoliosis, and evaluate imaging characteristics.
Method: The radiological and clinical data of 98 case, among them, 41 cases of adult idiopathic scoliosis and 57 cases of degenerative scoliosis, were analyzed retrospectively.
Result: There were differences at presence age, sex ratio, anatomic area of scoliosis and apex between two types of adult scoliosis.
Zhongguo Zhong Yao Za Zhi
September 2005
Objective: To observe the biomechanic properties of sciatic nerve at the suture site in rats following repairing.
Methods: The right sciatic nerves of 40 white Sprague-Dawley 300-350 gm rats were exposed, cut and then repaired with 10-0 nylon sutures, laced in the epineurium. 0, 1, 3, 6 weeks after operation, the tensile strength of the sciatic nerves were measured, the data analyzed statistically.