Publications by authors named "Ji-Suk Shim"

This study aimed to investigate the effects of crown seating speed, crown seating force, quantity of cement used, and type of implant cement on the amount of remnant cement in the subgingival region (RCS) after cementation. Cement-retained implant crowns were cemented to titanium abutments using the following methods: four types of implant cement (TBN: TEMP BOND NE, NR: NEXUS RMGI, ME: MAXCEM ELITE, and U200: RELYX U200), three quantities of cement (0.02 ml, 0.

View Article and Find Full Text PDF

(1) Background: To compare the degree of conversion of resin cores in various types of cavities and determine an effective irradiation method for achieving a higher degree of conversion. (2) Methods: Four different-sized cavities (narrow-shallow, narrow-deep, wide-shallow, and wide-deep) were simulated using a Teflon mold. The light irradiance reaching the bottom of each mold was measured by positioning a radiometer.

View Article and Find Full Text PDF

Although self-adhesive resin cements are convenient and less technique-sensitive materials for dental clinicians, they exhibit a lower degree of conversion due to acidic components in their composition. Supplementation of the initiator, accelerator, and activator in self-adhesive resin cements has been suggested to compensate for the lower degree of conversion. This study aimed to evaluate the effects of different combinations of self-curing initiators, self-curing activators, and accelerators on the degree of conversion (DC) of self-adhesive resin cements.

View Article and Find Full Text PDF

This study aimed to evaluate the effects of dentin bonding agents and silanization on the bond strength between 3D printed resin and composite resin and compare it with a conventional composite resin. 3D printed resin cylinders (PCB) and composite resin substrates (Z250) were prepared and divided into eight subgroups based on the bonding agents used (n=12). The shear bond strength was measured using a universal testing machine, and the failure modes were evaluated.

View Article and Find Full Text PDF

To manufacture dental restorations composed of lithium disilicate (LD) through the computer-aided design and manufacturing (CAD/CAM) process, thermal refinement is an essential process that can affect the optical and mechanical properties of ceramics. In this study, we aimed to evaluate the translucency and flexural strength of lithium disilicate glass-ceramic for CAD/CAM using different thermal refinement schedules and thicknesses by measuring the total transmission of light through the specimen and calculating the peak load of the specimen until fracture in a piston-on-three-ball test, respectively. The results showed that a lower translucency was exhibited in thicker specimens, and the flexural strength decreased in the order of 1.

View Article and Find Full Text PDF

The aim of this prospective study is to investigate implant stability and the reliability of different measuring devices according to implant placement site and duration in patients aged over 65 years. The study evaluated 60 implants (diameter: 3.5/4.

View Article and Find Full Text PDF

Purpose: The aim of this study was to evaluate the reliability of implant stability measuring devices depending on the location of the implant and the position of the patient.

Materials And Methods: Six implants were installed in different dentate sextants of six artificial bone models. Implant stability was measured in three conditions of the bone model (without mounting on a phantom head, mounted on a phantom head in supine position, and mounted on a phantom head in upright position).

View Article and Find Full Text PDF

Objectives: This study aimed to evaluate the effect of aging on the changes in implant stability over time following implant placement.

Materials And Methods: A total of 104 patients in four age ranges (group 1: <60 years, group 2: 61-70 years, group 3: 71-80 years, and group 4: >80 years) were included. Bone-level tapered implants were placed without implementing any bone augmentation procedure.

View Article and Find Full Text PDF

To evaluate the stability of a dental implant and the effectiveness of a newly designed damping capacity assessment device by improving the number of blows and strength evaluated by a prospective clinical study. The stability of dental implants was measured in 50 implants in a total of 38 patients. Measurements were performed using Anycheck and Periotest M devices, twice in total, divided into buccal and lingual directions.

View Article and Find Full Text PDF

Statement Of Problem: Microleakage and loss of the composite resin sealing the screw-access channel are frequent complications of screw-retained implant-supported prostheses. How the screw-access channel should be best restored to reduce such complications is unclear.

Purpose: The purpose of this in vitro study was to evaluate the microleakage and bond strength of 3 types of composite resins (flowable, packable, and bulk-fill) with or without a bonding agent treatment to seal the screw-access channel of 2 types of restorative materials (zirconia and Co-Cr alloy) with or without thermocycling.

View Article and Find Full Text PDF

Synthetic scaffolds, as bone grafts, provide a favorable environment for the repair and growth of new bone tissue at defect sites. However, the lack of angio- and osteo-induction limits the usefulness of artificial scaffolds for bone regeneration. Nitric oxide (NO) performs essential roles in healing processes, such as regulating inflammation and addressing incomplete revascularization.

View Article and Find Full Text PDF

Purpose: The aim of this study was to evaluate the labio-lingual alterations of the alveolar bone where the implant was placed immediately after tooth extraction.

Materials And Methods: Implants were placed immediately after tooth extraction on anterior alveolar ridges in the maxilla and mandible. The pin-guide system was used to help determine the location and path of implants during the surgical process.

View Article and Find Full Text PDF

The damaged site of a palatal wound is difficult to repair and often remains unclosed due to failure of the healing process, which occurs in inadequate environments of the oral cavity. Nitric oxide (NO) has effective functions in repairing damaged tissues, but it has a limitation due to short lifetime and rapid diffusion. Here, we synthesize a donor to deliver exogenous NO gas and verify its therapeutic effect for the palatal wound healing, which is known to take longer for healing due to the poor environment of warm saliva containing millions of microbes.

View Article and Find Full Text PDF

The aim of this study was to present a control method for modulating the translucency of lithium disilicate ceramics through thermal refinement. Identical lithium disilicate blocks were thermally refined using four different heat treatment schedules, and the microstructure, translucency, and flexural strength of the ceramics were investigated in detail by SEM, spectroscopy, and a piston-on-three-ball test. The results showed that ceramics treated under higher heat had larger grains, with an average size between 240 and 1080 nm.

View Article and Find Full Text PDF

Three-dimensional (3D) printing is increasingly being utilized in the dental field. After fabricating a prosthesis using a 3D printed resin, a post-curing process is required to improve its mechanical properties, but there has been insufficient research on the optimal post-curing conditions. We used various 3D printed crown and bridge materials in this study, and evaluated the changes in their properties according to post-curing time by evaluating the flexural strength, Weibull modulus, Vickers hardness, color change, degree of conversion, and biocompatibility.

View Article and Find Full Text PDF

Purpose: The purpose of this study was to examine the reliability of the Anycheck device and the effect of the healing abutment diameter on the Anycheck values (implant stability test, IST).

Materials And Methods: Thirty implants were placed into three artificial bone blocks with 10 Ncm, 15 Ncm, and 35 Ncm insertion torque value (ITV), respectively (n = 10). (1) The implant stability was measured with three different kinds of devices (Periotest M, Osstell ISQ Mentor, and Anycheck).

View Article and Find Full Text PDF

The aim of this study was to evaluate the effect of rheumatic disease as a risk factor for temporomandibular disease (TMD). A total of 143 outpatients reporting symptoms indicating rheumatic disease at their first visit to the rheumatology clinic were included. We evaluated the temporomandibular joint (TMJ) with scintigraphic images, and standard questionnaires were administered for the symptomatic assessment for all patients.

View Article and Find Full Text PDF

Statement Of Problem: Printing orientation is an important decision in the initial steps of additive manufacturing, affecting printing accuracy and the mechanical properties of printed products. In addition, printing orientation determines the building direction of layers and the layer-by-layer configuration forming the surface geometry.

Purpose: The purpose of this in vitro study was to evaluate the effect of printing orientation on the printing accuracy, flexural strength, surface characteristics, and microbial response of 3D-printed denture base resin.

View Article and Find Full Text PDF

Purpose: The aim of this study was to evaluate the responses of human gingival fibroblast (HGF-1) in contact with provisional materials with various chemical compositions and fabricated using different methods.

Materials And Methods: A total of 210 specimens in eight experimental groups were used. Groups were divided by chemical compositions (poly[ethyl methacrylate], poly[methyl methacrylate], bis-acryl, and hybrid ceramic) and fabricating methods (direct, indirect, and computer-aided design/computer-aided manufacturing [CAD/CAM]).

View Article and Find Full Text PDF

This study describes the successful synthesis of nitric oxide (NO)-releasing compounds with biodegradable and injectable properties and demonstrates that the kinetics of NO release vary according to the type of NO donor. The antimicrobial activity of NO-releasing compounds against three common periodontal pathogens, i.e.

View Article and Find Full Text PDF

Objective: The aim of this study was to investigate the polymerization mode of self-adhesive, dual-cured resin cements light-cured through overlying materials with different degree of translucency by measuring the degree of conversion (DC).

Materials And Methods: Three kinds of self-adhesive, dual-cured resin cements (G-CEM LinkAce , Maxcem Elite , and BisCem ) were light-cured through three different restorative materials that included porcelain-fused metal (PFM), zirconia, and lithium disilicate. Polymerization kinetics were continuously evaluated using infrared spectroscopy after 0, 5, 10, and 30 min and 2 weeks of mixing.

View Article and Find Full Text PDF

The most common complication of implant ball attachments is loss of retention via structural wear. Hence, parallel placement of implants was identified as a prerequisite for long-term success. In this case, although severe angulation was formed between implants due to severe alveolar bone resorption, parallel ball attachments on the implants could be fabricated using computer-aided design/computer-assisted manufacture.

View Article and Find Full Text PDF

Objective: This study investigated the marginal and internal adaptation of individual dental crowns fabricated using a CAD/CAM system (Sirona's BlueCam), also evaluating the effect of the software version used, and the specific parameter settings in the adaptation of crowns.

Material And Methods: Forty digital impressions of a master model previously prepared were acquired using an intraoral scanner and divided into four groups based on the software version and on the spacer settings used. The versions 3.

View Article and Find Full Text PDF

Purpose: To analyze the accuracy of impressions in relation to implant angulation and type of impression coping.

Materials And Methods: Three metal master models with 2 implants of 3 different angulations (parallel, mesiodistal, and buccolingual) were fabricated. Nine groups of experimental models were fabricated to duplicate the 3 master models using 3 types of impression copings: transfer, pick-up, and hybrid.

View Article and Find Full Text PDF

Purpose: This study aimed to discover a way to increase the bond strength between bis-acryl resins, using a comparison of the shear bond strengths attained from bis-acryl resins treated with light curing, pressure, oxygen inhibition, and heat.

Materials And Methods: Self-cured bis-acryl resin was used as both a base material and as a repair material. Seventy specimens were distributed into seven groups according to treatment methods: pressure - stored in a pressure cooker at 0.

View Article and Find Full Text PDF

A PHP Error was encountered

Severity: Warning

Message: fopen(/var/lib/php/sessions/ci_sessionlv82bvkajrtpgcuqipc3rgduqf6tagtn): Failed to open stream: No space left on device

Filename: drivers/Session_files_driver.php

Line Number: 177

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_start(): Failed to read session data: user (path: /var/lib/php/sessions)

Filename: Session/Session.php

Line Number: 137

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once