Seventeen laboratories participated in three interlaboratory exercises to assess the performance of refractive index, micro X-ray Fluorescence Spectroscopy (μXRF), and Laser Induced Breakdown Spectroscopy (LIBS) data for the forensic comparison of glass samples. Glass fragments from automotive windshields were distributed to the participating labs as blind samples and participants were asked to compare the glass samples (known vs. questioned) and report their findings as they would in casework.
View Article and Find Full Text PDFCalcium fluoride formed by the reaction between ammonium bifluoride and calcium chloride was investigated as a dominating matrix for quantitative analysis by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). Transformation from a solid sample to the calcium fluoride-based matrix permitted quantitative analysis based on calibration standards made from elemental standards. A low abundance stable calcium isotope, i.
View Article and Find Full Text PDFThe contribution and impact of combined laser ablation inductively coupled plasma time-of-flight mass spectrometry (LA-ICP-TOF-MS) and laser-induced breakdown spectroscopy (LIBS) were evaluated for the discrimination analysis of different coal samples. This tandem approach allows simultaneous determination of major and minor elements (C, H, Si, Ca, Al, Mg, etc.) and trace elements (V, Ba, Pb, U, etc.
View Article and Find Full Text PDFBackground: Sialolithiasis or salivary gland stones are associated with high clinical morbidity. The advances in the treatment of sialolithiasis has been limited, however, by our understanding of their composition. More specifically, there is little information regarding the formation and composition of the protein matrix, the role of mineralogical deposition, or the contributions of cell epithelium and secretions from the salivary glands.
View Article and Find Full Text PDFLaser-induced breakdown spectroscopy (LIBS) and laser ablation inductively coupled plasma optical emission spectrometry (LA-ICP-OES) were used simultaneously for the elemental analysis of asphaltene samples using minimum sample pretreatment in combination with low laser energy to reduce the amount of removed particles and avoid carbon deposits in the ablation cell. Quantitative analyses of S, Ni, and V were accomplished with LA-ICP-OES using external calibration with the C line as internal standard. The aromatic/paraffinic nature of the asphaltenes was also obtained throughout the H/C ratio using LIBS and partial least square regression model.
View Article and Find Full Text PDFMultilayered fragments of murals were used to evaluate the usefulness of two laser-based instrumental methods: laser induced breakdown spectroscopy (LIBS) and laser ablation (LA) inductively coupled plasma mass spectrometry (ICP-MS) for elemental imaging of unique historic samples. Simultaneous LA/LIBS measurements with the use of 266nm Nd:YAG laser were performed on cross-sections of mediaeval Nubian objects with specific blue painting layers including either Egyptian blue (CaCuSiO) or lapis lazuli (NaAlSiOS). A combined use of both laser-based methods allowed for clear distinguishing of blue pigments based on visual imaging of a chemical composition of heterogeneous archaeological inorganic samples.
View Article and Find Full Text PDFSolid sampling and analysis methods, such as laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS), are challenged by matrix effects and calibration difficulties. Matrix-matched standards for external calibration are seldom available and it is difficult to distribute spikes evenly into a solid matrix as internal standards. While isotopic ratios of the same element can be measured to high precision, matrix-dependent effects in the sampling and analysis process frustrate accurate quantification and elemental ratio determinations.
View Article and Find Full Text PDFWe evaluated the performance of laser ablation analysis techniques such as laser-induced breakdown spectroscopy (LIBS), laser ablation inductively coupled optical emission spectrometry (LA-ICP-OES), and laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS), in comparison with that of ICP-OES using aqueous solutions for the quantification of sulfur (S) in edible salts from different geographical origins. We found that the laser ablation based sampling techniques were not influenced by loss of S, which was observed in ICP-OES with aqueous solutions for a certain salt upon their dissolution in aqueous solutions, originating from the formation of volatile species and precipitates upon their dilution in water. Although detection of S using direct laser sampling with LA-ICP-MS has well-known isobaric and polyatomic interferences, LIBS and LA-ICP-OES showed good accuracy in the detection of S for all salts.
View Article and Find Full Text PDFDirect solid sampling by laser ablation into an inductively coupled plasma synchronous vertical dual view optical emission spectroscope (LA-SVDV-ICP-OES) was used for the elemental analysis of nutrient elements Ca, B, Mn, Mg, K, and Zn and essential (non-metallic) elements P and S in plant materials. The samples were mixed with paraffin as a binder, an approach that provides better cohesion of the particles in the pellets in addition to supplying carbon to serve as an internal standard (atomic line C I 193.027 nm) as a way to compensate for matrix effects, and/or variations in the ablation process.
View Article and Find Full Text PDFSome reports indicate that the silver released from dermally applied products containing silver nanoparticles (AgNP) (e.g. wound dressings or cosmetics) can penetrate the skin, particularly if damaged.
View Article and Find Full Text PDFLiquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma is being developed as a secondary vaporization-excitation source for the optical emission analysis of laser ablation (LA)-generated particle populations. The practicalities of this coupling are evaluated by determining the influence of source parameters on the emission response and the plasma's robustness upon LA introduction of easily ionized elements (EIEs). The influence of discharge current (45-70 mA), LA carrier gas flow rate (0.
View Article and Find Full Text PDFIn 2002, we wrote an Analytical Chemistry feature article describing the Physics of Laser Ablation in Microchemical Analysis. In line with the theme of the 2002 article, this manuscript discusses current issues in fundamental research, applications based on detecting photons at the ablation site (LIBS and LAMIS) and by collecting particles for excitation in a secondary source (ICP), and directions for the technology.
View Article and Find Full Text PDFLaser ablation molecular isotopic spectrometry (LAMIS) recently was reported for rapid isotopic analysis by measuring molecular emission from laser-induced plasmas at atmospheric pressure. This research utilized the LAMIS approach to study C2 molecular formation from laser ablation of carbon isotopic samples in a neon gas environment at 0.1 MPa.
View Article and Find Full Text PDFKidney stones were analyzed using laser-induced breakdown spectroscopy (LIBS), utilizing a high resolution multi-channel charge-coupled device (CCD) spectrometer and a nanosecond-pulse Nd : YAG laser. The kidney stones were also characterized using X-ray diffraction (XRD) and X-ray fluorescence (XRF) techniques for comparative analysis. It was found that the ratio of hydrogen (H) to carbon (C) was an important indicator of organic compounds such as uric acid.
View Article and Find Full Text PDFLaser ablation is becoming a dominant technology for direct solid sampling in analytical chemistry. Laser ablation refers to the process in which an intense burst of energy delivered by a short laser pulse is used to sample (remove a portion of) a material. The advantages of laser ablation chemical analysis include direct characterization of solids, no chemical procedures for dissolution, reduced risk of contamination or sample loss, analysis of very small samples not separable for solution analysis, and determination of spatial distributions of elemental composition.
View Article and Find Full Text PDFPulsed laser ablation (266nm) was used to generate glass particles from two sets of standard reference materials using femtosecond (150fs) and nanosecond (4ns) laser pulses with identical fluences of 50Jcm(-2). Scanning electron microscopy (SEM) images of the collected particles revealed that there are more and larger agglomerations of particles produced by nanosecond laser ablation. In contrast to the earlier findings for metal alloy samples, no correlation between the concentration of major elements and the median particle size was found.
View Article and Find Full Text PDFPulsed laser ablation (266nm) was used to generate metal particles of Zn and Al alloys using femtosecond (150fs) and nanosecond (4ns) laser pulses with identical fluences of 50Jcm(-2). Characterization of particles and correlation with inductively coupled plasma mass spectrometer (ICP-MS) performance was investigated. Particles produced by nanosecond laser ablation were mainly primary particles with irregular shape and hard agglomerates (without internal voids).
View Article and Find Full Text PDF