Background: All modern defibrillation systems use biphasic shock waveforms. Typically a fixed tilt waveform is used for implantable defibrillators (ICDs), but a tuned waveform with duration based on shock impedance may be superior based on theoretical calculations.

Objective: The objective of this study was to compare defibrillation efficacy of fixed tilt and tuned waveforms.

View Article and Find Full Text PDF

Background: The efficacy of tuned defibrillation waveforms versus the nominal fixed-tilt waveform has been previously studied. However, the optimal membrane time constant for tuning was not known. The POWER (Pulsewidth Optimized Waveform Evaluation tRial) trial was designed to determine the optimal membrane time constant for programming "tuned" biphasic waveforms.

View Article and Find Full Text PDF

Aims: Advanced cardiac disease, entailing more hypertrophy, fibrosis, scarring, dilatation and conduction delays, poses the question of whether defibrillation thresholds (DFTs) increase as left ventricular ejection fraction (LVEF) decreases. This question has been approached indirectly or insufficiently in previous studies. In this study we add and expand on our previous work, stratifying DFT for various LVEF ranges.

View Article and Find Full Text PDF

Background: The maturation of the high-voltage impedance (HVLI) of defibrillating leads has not been explored thoroughly. Since impedance influences the charge, current, and energy delivered to the heart in both fixed pulse-width and fixed tilt implantable cardioverter-defibrillator (ICD) waveforms, changes in HVLI might have an effect on the defibrillation threshold. This analysis examined the maturation of defibrillation lead HVLI.

View Article and Find Full Text PDF

Introduction: Right ventricular (RV) anodal stimulation may occur in cardiac resynchronization therapy defibrillators (CRT-D) when left ventricular (LV) pacing is configured between the LV lead and an electrode on the RV defibrillator lead. RV defibrillator leads can have a dedicated proximal pacing ring electrode (dedicated bipolar) or utilize the distal shocking coil as the proximal pacing electrode (integrated bipolar). This study compares the performance of integrated versus dedicated leads with respect to anodal stimulation incidence, sensing, and inappropriate ventricular tachyarrhythmia detection in patients implanted with CRT-D.

View Article and Find Full Text PDF

The ability to optically image structures and instrumentation within the heart during procedures is limited by the presence of blood in the field. The goal of our research was to design, develop, and evaluate technology for a catheter-based optical imaging system that enables intracardiac and intravascular visualization in real time through blood. Based on Mie optical scattering theory, imaging through blood using infrared light was theoretically feasible, but scattering in the near-infrared wavelengths (1100 to 1300 nm) generated substantial noise in the image despite relatively low absorption.

View Article and Find Full Text PDF

Background: Prior studies of active pectoral implantable defibrillator (ICD) lead systems demonstrated a lowering of defibrillation thresholds (DFTs) with the addition of a superior vena cava (SVC) coil. These studies were done on fixed-tilt waveforms where a large reduction in impedance leads to large phase duration changes.

Objective: The present study was designed to evaluate the SVC coil benefit and intercoil spacing on DFTs with a "tuned" waveform.

View Article and Find Full Text PDF

Background: Atrial overdrive pacing algorithms may be effective in preventing or suppressing atrial fibrillation (AF). However, the maintenance of a heart rate incessantly faster than spontaneous could induce left ventricular (LV) dysfunction and promote heart failure (HF) on the long term.

Objective: This post hoc analysis examined the effects of a new overdrive algorithm on the incidence of HF-related adverse events in 411 patients enrolled in the ADOPT-A trial.

View Article and Find Full Text PDF

Background: We report on 4 patients (aged 57 to 77 years; 3 men) who developed drug-refractory, repetitive ventricular tachyarrhythmias after acute myocardial infarction (MI). All episodes of ventricular arrhythmias were triggered by monomorphic ventricular premature beats (VPBs) with a right bundle-branch block morphology (RBBB).

Methods And Results: Left ventricular (LV) mapping was performed to attempt radiofrequency (RF) ablation of the triggering VPBs.

View Article and Find Full Text PDF

Objectives: The Atrial Dynamic Overdrive Pacing Trial (ADOPT) was a single blind, randomized, controlled study to evaluate the efficacy and safety of the atrial fibrillation (AF) Suppression Algorithm (St. Jude Medical Cardiac Rhythm Management Division, Sylmar, California) in patients with sick sinus syndrome and AF.

Background: This algorithm increases the pacing rate when the native rhythm emerges and periodically reduces the rate to search for intrinsic atrial activity.

View Article and Find Full Text PDF