Statement Of Problem: Additive (3-dimensional printing) and subtractive (milling) methods are digital approaches to fabricating zirconia restorations. Comparisons of their resultant fabrication accuracy and restoration fit are lacking.
Purpose: The purpose of this systematic review and meta-analysis was to evaluate the accuracy and fit of monolithic zirconia crowns fabricated by 3-dimensional printing and milling.
Background/purpose: Translucent monolithic zirconia restorations have recently introduced. The purpose of this study was to evaluate the clinical behavior and the survival rate of the posterior third-generation monolithic zirconia crowns (MZCs) during three years of clinical service.
Materials And Methods: Twenty-four patients who needed thirty crowns were enrolled in this study.
The immediate loading protocol has become increasingly popular due to the progressive growth in demand for a reduction in treatment times. The possibility of applying this protocol would depend on certain important factors. The application of the digital workflow mentioned in the protocol guarantees rapidity, precision, and esthetics.
View Article and Find Full Text PDFThe purpose of this study was to investigate the effect of low-pressure plasma on the contact angle, shear bond strength (SBS), and the failure mode of zirconia ceramic. Zirconia specimens were divided into three groups according to the surface treatment methods as follows: sandblasting with aluminum oxide (ZR-C), sandblasting with aluminum oxide and oxygen plasma (ZR-CP), and argon plasma (ZR-P). The contact angle, SBS, and surface characteristics were tested after thermocycling.
View Article and Find Full Text PDFPurpose To evaluate and compare the survival, success rates, and biological and technical complications of three-unit posterior monolithic and veneered zirconia and metal-ceramic (MC) posterior fixed partial dentures (FPDs) fabricated using a digital workflow and computer-aided design and computer-aided manufacturing (CAD/CAM) over a 5-year follow-up.Methods Ninety patients in need of three-unit posterior FPDs were randomized to receive monolithic zirconia (MZ), veneered zirconia (VZ), and MC restorations (n = 30 each). Teeth preparations were scanned using an intraoral scanner, and restorations were milled and cemented with resin cement.
View Article and Find Full Text PDFThis clinical report describes a mandibular full-arch rehabilitation by means of an implant-supported overdenture on four zirconia implants. A female patient with an edentulous mandibular arch attended our dental clinic seeking a metal-free mandibular restoration. After oral and radiographic evaluation, four one-piece zirconia implants with conical abutments were placed in the intermentonian region.
View Article and Find Full Text PDFObjectives: To evaluate and to compare the clinical performance and survival rate of posterior monolithic and veneered zirconia fixed partial dentures (FPDs).
Material And Methods: Sixty 3-unit posterior FPDs were included in the study. The patients were randomly distributed into two groups (n = 30 each) to receive either a monolithic (Zenostar T, Wieland Dental) or veneered zirconia (IPS e.
Clinical studies on the behavior of posterior translucent monolithic zirconia restorations are lacking. We assessed the clinical outcome and survival rate of posterior third-generation monolithic zirconia crowns over a 2-year period. A total of 24 patients, requiring 30 posterior full-contour restorations were selected.
View Article and Find Full Text PDFPurpose: To compare the load to fracture of cobalt-chromium (Co-Cr) 3-unit posterior fixed partial denture (FPD) frameworks manufactured by conventional and digital techniques and to evaluate the influence of the framework design on the fracture load.
Material And Methods: Eighty 3-unit Co-Cr posterior FPD frameworks were fabricated with two designs: intermediate pontic (n = 40) and cantilever (n = 40). Each design was randomly divided into four groups (n = 10): casting, direct metal laser sintering, soft metal milling, and hard metal milling.
Biology (Basel)
June 2021
The aim of this study was to assess the long-term clinical behavior of straight implants in comparison with intentionally tilted dental implants (ITDI) supporting fixed restorations in partial or total edentulous arches, analyzing implant survival and success rates, complications, and marginal bone loss (MBL) after >5 years of function. An electronic search was conducted in five electronic databases (MEDLINE/Pubmed, Embase, Web of Science, Scopus, and Cochrane Central Register of Controlled Trials) supplemented by a manual search. The electronic and manual search identified 1853 articles, of which 8 articles were selected for analysis.
View Article and Find Full Text PDFThis systematic review aims to evaluate the different pretreatments of the zirconia surface and resin cement in order to determine a valid operative protocol for adhesive cementation. Methodologies conducted for this study followed the Prisma (Preferred Reporting Items for Systematic Reviews and Meta-Analysis) guidelines. An electronic search was performed in four databases.
View Article and Find Full Text PDFUnlabelled: The aim of this study was to investigate the load to fracture and fracture pattern of prosthetic frameworks for tooth-supported fixed partial dentures (FPDs) fabricated with different subtractive computer-aided design and computer-aided manufacturing (CAD-CAM) materials.
Materials And Methods: Thirty standardized specimens with two abutments were fabricated to receive three-unit posterior FDP frameworks with an intermediate pontic. Specimens were randomly divided into three groups (n = 10 each) according to the material: group 1 (MM)-milled metal; group 2 (L)-zirconia; and group 3 (P)-Polyetheretherketone (PEEK).
The purpose of this scoping review was to describe the current state of knowledge and understanding of allergies to titanium dental implants. A scoping review was conducted following the Prisma Extension for Scoping Reviews checklist. An electronic search was performed in five databases complemented by manual and grey literature searches.
View Article and Find Full Text PDFThe precision of fit at the implant-abutment connection is an important criterion for the clinical success of restorations and implants. Several factors are involved among which are the abutment materials and manufacturing techniques. The aim of this study was to investigate the effect of two materials and methods of manufacturing implant abutments, milled titanium versus laser sintered Co-Cr, on the marginal misfit at the implant-abutment interface.
View Article and Find Full Text PDFPurpose To evaluate the influence of intraoral and extraoral digitization systems on marginal discrepancy of monolithic lithium disilicate and monolithic zirconia computer-aided design-computer-aided manufacturing (CAD-CAM) crowns.Methods Forty standardized machined stainless steel specimens with the characteristics of a first molar were manufactured and randomly assigned to two groups (n=20 each), depending on their material: monolithic lithium disilicate ceramic (LM), and monolithic zirconia (ZM). Then, each group was subdivided into two depending on the scanning system used: intraoral scanner (IOS), and extraoral scanner (EOS).
View Article and Find Full Text PDFPurpose: To evaluate the clinical performance and survival rate of posterior monolithic zirconia fixed partial dentures over a 2-year period.
Material And Methods: A total of 20 patients, requiring 20 posterior fixed partial dentures were included in the study. Tooth preparations were scanned, and restorations were milled and cemented with a resin cement.
Background: An accurate fit at the implant-abutment interface is an important factor to avoid biological and mechanical complications. The aim of this study was to evaluate the marginal misfit at the implant-abutment interface on external and Morse taper connection, with straight and angulated abutments under different insertion torque loads.
Materials And Methods: A total of 120 implants were used, 60 with external connection (EC) and 60 with Morse taper connection (IC).
Statement Of Problem: Evidence of the behavior of the periodontal tissues around anterior teeth restored with the biologically oriented preparation technique (BOPT) is available. However, outcomes of this technique in posterior teeth restored with fixed partial dentures (FPDs) are lacking.
Purpose: The purpose of this randomized controlled clinical trial was to evaluate the clinical, mechanical, and biological behavior of posterior 3-unit FPDs placed on teeth prepared with BOPT.
Purpose: To evaluate the influence of static (not preloaded) and thermomechanical loading on the load to fracture of metal-ceramic, monolithic and veneered zirconia computer-aided design/computer-aided manufacturing (CAD/CAM) posterior fixed partial dentures (FPDs).
Materials And Methods: One hundred standardized specimens with 2 abutments screwed onto a platform were prepared from stainless steel to receive a posterior 3-unit FPD with an intermediate pontic. Specimens were randomly divided into 5 groups (n = 20): Metal-ceramic (control group), Lava Zirconia system, Vita In-Ceram YZ, IPS e.
Purpose: To compare the survival, success rates, and biological/technical complications of posterior metal-ceramic (MC) and zirconia fixed partial dentures (FPDs).
Materials And Methods: A total of 40 patients requiring 40 posterior FPDs were randomly assigned to receive 20 zirconia and 20 MC restorations. The restorations were examined 1 week (baseline) and 1, 3, and 5 years after the end of treatment.
The purpose of this study was to evaluate and to compare the fracture load and the fracture pattern of monolithic and veneered zirconia posterior fixed dental prostheses (FDPs). Twenty standardized steel dies were prepared to receive posterior 3-unit FDPs. Specimens were randomly divided into 2 groups (n=10): (1) Lava Zirconia, and (2) Lava Plus.
View Article and Find Full Text PDFPurpose: To evaluate the fracture load of 3-unit zirconia-based posterior fixed dental prostheses (FDPs) before and after veneering the frameworks.
Materials And Methods: Forty standardized stainless-steel master dies were fabricated (height: 5 mm, convergence: 6º, chamfer: 1 mm) and randomly screwed in pairs onto metal bases. The bases were randomly divided into two groups (n = 20 each) according to the zirconia CAD/CAM system used for constructing 3-unit structures for FDPs: group 1 (L): Lava All-ceramic, group 2 (Z): IPS e.
Legionnaires' disease is a severe form of pneumonia, with worldwide relevance, caused by Legionella spp. Approximately 90% of all cases of legionellosis are caused by Legionella pneumophila, but other species can also be responsible for this infection. These bacteria are transmitted by inhalation of aerosols or aspiration of contaminated water.
View Article and Find Full Text PDFPurpose: The aim of this study was to investigate and compare the marginal fit of posterior fixed dental prostheses (FDPs) made of monolithic and veneered computer-aided design/computer-assisted manufacture (CAD/CAM) zirconia ceramic with metal-ceramic posterior FDPs.
Materials And Methods: Thirty standardized steel dies were prepared to receive posterior three-unit FDPs. Specimens were randomly divided into three groups (n = 10): (1) metal-ceramic (control group), (2) veneered zirconia, and (3) monolithic zirconia.