Statement Of Problem: Obtaining a passive and well-adapted framework is challenging when intraoral scanning edentulous arches with multiple implants. The trueness of the printed casts is unclear.
Purpose: The purpose of this clinical study was to evaluate the trueness of frameworks made from conventional and printed casts regarding clinical passivity and misfit.
J Prosthet Dent
December 2024
Statement Of Problem: Monolithic ceramic implant-supported restorations have been used to rehabilitate partially edentulous patients. However, knowledge of the survival and prosthetic complications of single crowns (SCs) and fixed partial dentures (FPDs) is limited.
Purpose: The purpose of this systematic review with meta-analysis was to evaluate the clinical performance of monolithic ceramic implant-supported SCs and FPDs in terms of survival and prosthetic complication rates.
Clin Oral Investig
July 2022
Objective: To assess whether wearing complete dentures during sleep influences the cardiorespiratory parameters of patients with obstructive sleep apnea (OSA).
Materials And Methods: A systematic review was performed based on Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines to determine whether wearing complete dentures during sleep influences the cardiorespiratory parameters of patients with OSA. An electronic search was performed in four databases, PubMed/MEDLINE, Cochrane Library, Web of Science, and SCOPUS, and in the gray literature (TRIALS) until November 2021.
Objective: The objective of this systematic review was to evaluate the efficacy of non-surgical periodontal therapy on rheumatoid arthritis activity.
Material And Methods: Articles published until April 2019 were electronically searched and screened using PubMed / MEDLINE, Scopus, and Cochrane databases according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines (PRISMA). This study was recorded in the international PROSPERO database (CRD42019132205).
J Prosthet Dent
January 2023
This article describes a technique for making complete-arch implant-supported fixed prostheses by using intraoral scanning and computer-aided design and computer-aided manufacturing (CAD-CAM) technology for the fabrication of a metal substructure and conventional processing for the prosthesis base. For this, a device was designed to accurately capture the position of multiple implants and the associated digitalized surgical guide, and the metal substructure was planned and milled directly in cobalt-chromium. The color of the gingiva and artificial teeth was selected by using the intraoral scanner software program, and the prosthesis base was processed conventionally.
View Article and Find Full Text PDFJ Oral Implantol
June 2022
This is an in silico study aimed to evaluate the biomechanical influence of different implant-abutment interfaces (external hexagon and Morse taper implants), retention systems (cement and screw retained), and restorative crowns (metal-ceramic and monolithic) using 3-dimensional finite element analysis (3D-FEA). Eight 3D models were simulated for the maxillary first molar area using InVesalius, Rhinoceros, and SolidWorks and processed using Femap and NEi Nastran software. Axial and oblique forces of 200 and 100 N, respectively, were applied on the occlusal surface of the prostheses.
View Article and Find Full Text PDFJ Prosthet Dent
August 2022
Statement Of Problem: A consensus on whether the use of a complete-denture adhesive provides a clinical benefit remains unclear.
Purpose: The purpose of this systematic review of randomized controlled trials was to evaluate the use of adhesive in complete dentures in terms of retention and stability, patient-reported outcomes measures, and masticatory performance.
Material And Methods: A search was performed in PubMed, Web of Science, and Cochrane Library for articles up to October 2020.
Sleep Breath
December 2021
Background: The impact of a complete denture on obstructive sleep apnea is not well understood. Therefore, this study aimed to evaluate the relationship between nighttime use of complete dentures and obstructive sleep apnea and determine if wearing a complete denture during sleep changes the degree of obstructive sleep apnea.
Methods: This systematic review followed the notification items for Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) and was recorded in the International Prospective Registry of Systematic Reviews (PROSPERO) under number CRD42020183167.
Gerodontology
September 2021
Objective: This study aimed to systematically review the literature regarding the surface roughness of polymethylmethacrylate (PMMA) for denture bases, disinfected with different chemical agents and analyse the outcomes of the included studies.
Background: Various chemical disinfection protocols to clean the removable dental prosthesis are reported in the literature, however systematic reviews analysing the outcomes in the surface roughness of the PMMA are lacking.
Methods: The Preferred Reporting Items for Systematic Review and Meta-Analyses (PRISMA) checklist was used to structure this systematic review.
Clin Oral Investig
February 2021
Background: The aim of this systematic review and meta-analysis (SRM) was to assess the postoperative pain (PP) after non-surgical endodontic retreatment (NSER) in a one visit compared to multiple visits. The PICO question used was "Does NSER in patients with unsatisfactory endodontic treatment in a one-visit visit have a similar PP to that of NSER in multiple visits?"
Materials And Methods: This systematic review followed PRISMA and was registered in PROSPERO (CRD42019136700). Searches were performed in the PubMed/MEDLINE, Scopus, and the Cochrane Library databases for articles published until September 2020.
Statement Of Problem: How the performance of dental implants is related to their occlusogingival placement, crestal or subcrestal, is unclear.
Purpose: The purpose of this systematic review and meta-analysis was to evaluate marginal bone loss, implant survival rate, and peri-implant soft tissue parameters between implants placed at the crestal and subcrestal bone level.
Material And Methods: Two independent reviewers searched the PubMed/MEDLINE, Embase, and Cochrane Library databases for randomized clinical trials published up to September 2020.
J Prosthet Dent
January 2021
Statement Of Problem: A consensus regarding the biomechanical effects of vertical bone loss in normal and osteoporotic bone tissue according to different implant-abutment interfaces is lacking.
Purpose: The purpose of this finite element analysis study was to evaluate the effect of vertical bone loss (without bone loss; with 1.5-mm bone loss; with 3-mm bone loss; and with 4.
J Contemp Dent Pract
June 2020
Aim: The aim of this study was to evaluate the available evidence to identify the influence of pterygomaxillary disjunction on the result of surgically assisted maxillary expansion.
Background: LeFort I type osteotomy with disjunction of the pterygomaxillary suture is a procedure widely used in maxillofacial surgery. However, the need for its performance during surgically assisted maxillary expansions has been discussed in literature, since serious complications can be caused during this stage.
The objective of this study was to perform a quality analysis of systematic reviews with meta-analyses that focused on the comparison of platform-switching (implant-abutment mismatching) and platform-matched (PM) implants. The assessment of multiple systematic reviews (AMSTAR) and Glenny (Checklist) Scales were used to qualify the studies. PubMed, Scientific Electronic Library Online (SciELO), Web of Science (formerly ISI Web of Knowledge), and Cochrane databases were searched, by topic, for systematic reviews on dental implants with switching platforms.
View Article and Find Full Text PDFStatement Of Problem: One-step dental implant surgery with a 1-piece implant has been introduced with the aim of simplifying and increasing the effectiveness of treatment and providing greater comfort for the patient. Whether these goals have been met compared with conventional 2-piece implants remains unclear.
Purpose: The purpose of this systematic review and meta-analysis was to compare the use of 1-piece versus 2-piece implants in terms of marginal bone loss and implant survival rate.
Purpose: To evaluate the vertical marginal (VM) and horizontal marginal (HM) misfit of frameworks made using different techniques.
Materials And Methods: A total of 30 frameworks were divided into three groups of 10 samples each based on manufacturing technique: nichrome cast (G1), milled in zirconia (G2), and milled in wax and fused to metal (G3). Marginal misfit was measured using a three-dimensional optical microscope.
We aimed to conduct an analysis of the systematic reviews (SRs) in literature about the implant survival rate (ISR) and marginal bone loss (MBL) in diabetic and nondiabetic patients. This work was registered in The International Prospective Register of Systematic Reviews (CRD42018095314) and was developed following Preferred Reporting Items for Systematic Reviews and Meta-Analyses and the Cochrane Library Handbook. A search was performed on PubMed, Cochrane, Scopus, Embase, and LILACS.
View Article and Find Full Text PDFInt J Prosthodont
October 2019
Purpose: To compare the marginal vertical misfit between implant-supported frameworks fabricated using CAD/CAM systems and the conventional technique (lost-wax casting).
Materials And Methods: This review was performed according to PRISMA criteria and registered on PROSPERO (CRD42017055685). An electronic search was performed independently by two examiners in the MEDLINE (Pubmed), Embase, Web of Science, and Cochrane Library databases to find studies published up to April 2018.
J Prosthet Dent
May 2019
Statement Of Problem: Consensus is lacking regarding the optimal number of implants for supporting complete-arch prostheses with good survival rates and lower prosthetic complications and marginal bone loss.
Purpose: The purpose of this systematic review was to evaluate the influence of the number of implants used for complete-arch prostheses with at least 5 years of follow-up.
Material And Methods: A search was performed in the PubMed/MEDLINE, Scopus, and Cochrane Library databases according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) criteria and was registered in The International Prospective Register of Systematic Reviews (CRD42016048468).
Int J Oral Maxillofac Implants
October 2018
Purpose: To investigate if the presence of a cantilever influences the survival and success of partial fixed implant-supported prostheses, through a systematic review and meta-analysis, with additional analysis of the survival and marginal bone loss rates and prosthesis complications.
Materials And Methods: The register protocol of the review in the PROSPERO database is CRD42016052008. The MEDLINE and Scopus databases were used for an electronic search of relevant studies up to November 2016, by means of two independent reviewers.