Directivity and gain in microphone array systems for hearing aids or hearable devices allow users to acoustically enhance the information of a source of interest. This source is usually positioned directly in front. This feature is called acoustic beamforming.
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
January 2009
Conventional Doppler methods for blood velocity estimation only estimate the velocity component along the ultrasound beam direction. This implies that a Doppler angle under examination close to 90 degrees results in unreliable information about the true blood direction and blood velocity. The novel method transverse oscillation (TO), which combines estimates of the axial and the transverse velocity components in the scan plane, makes it possible to estimate the vector velocity of the blood regardless of the Doppler angle.
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
August 2008
Conventional ultrasound methods for acquiring color images of blood velocity are limited by a relatively low frame-rate and are restricted to give velocity estimates along the ultrasound beam direction only. To circumvent these limitations, the method presented in this paper uses 3 techniques: 1) The ultrasound is not focused during the transmissions of the ultrasound signals; 2) A 13-bit Barker code is transmitted simultaneously from each transducer element; and 3) The 2-D vector velocity of the blood is estimated using 2-D cross-correlation. A parameter study was performed using the Field II program, and performance of the method was investigated when a virtual blood vessel was scanned by a linear array transducer.
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
October 2008
This paper investigates the use of coded excitation for blood flow estimation in medical ultrasound. Traditional autocorrelation estimators use narrow-band excitation signals to provide sufficient signal-to-noise-ratio (SNR) and velocity estimation performance. In this paper, broadband coded signals are used to increase SNR, followed by subband processing.
View Article and Find Full Text PDFIn this paper, a case study of in-vivo blood vector velocity images of the carotid artery are presented. The transverse oscillation (TO) method for blood vector velocity estimation has been used to estimate the vector velocities. The carotid arteries of three healthy volunteers are scanned in-vivo at three different positions by experienced sonographers.
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
May 2006
Conventional ultrasound scanners can display only the axial component of the blood velocity vector, which is a significant limitation when vessels nearly parallel to the skin surface are scanned. The transverse oscillation (TO) method overcomes this limitation by introducing a TO and an axial oscillation in the pulse echo field. The theory behind the creation of the double oscillation pulse echo field is explained as well as the theory behind the estimation of the vector velocity.