Purpose: Comparison of two hexapod frame systems in paediatric tibial deformity correction; the Taylor Spatial Frame (TSF) and Orthex Hexapod System.
Methods: Paediatric patients with congenital and acquired tibial deformities treated with either TSF (between 2014 and 2016) or Orthex (between 2017 and 2019) frames were included in a retrospective comparative study. Outcome measures were healing index, pin infection rate, regenerate quality and density, software residual rate, deformity correction accuracy, strut exchanges and quality of life (QoL).