Posterior ligamentous complex (PLC) and intervertebral disc (IVD) injuries are common cervical spine flexion-distraction injuries, but the residual stability following their disruption is misknown. The objective of this study was to evaluate the effect of PLC and IVD disruption on post-traumatic cervical spine stability under low flexion moment (2 Nm) using a finite element (FE) model of C2-T1. The PLC was removed first and a progressive disc rupture (one third, two thirds and complete rupture) was modeled to simulate IVD disruption at C2-C3, C4-C5 and C6-C7.