Renal echo planar diffusion tensor imaging (DTI) has clinical potential but suffers from geometric distortion. We evaluated feasibility of reversed gradient distortion correction in 10 diabetic patients and 6 volunteers. Renal area, apparent diffusion coefficient, fractional anisotropy, and tensor eigenvalues were measured on uncorrected and distortion-corrected DTI.
View Article and Find Full Text PDFBackground And Purpose: Distal clot migration is a recognized event following intravenous thrombolysis (IVT) in the setting of acute ischemic stroke. Of note, clots that were initially retrievable by endovascular thrombectomy may migrate to a distal nonretrievable location and compromise clinical outcome. We investigated the incidence of clot migration leading to clot inaccessibility following IVT in the time window of 4.
View Article and Find Full Text PDFObjective: The aim of this study was to evaluate image quality and accuracy of 64+ detector multidetector computed tomography angiography (MDCTA) for hemodynamically significant (≥50%) stenosis in patients with symptomatic peripheral arterial disease (PAD) using digital subtraction angiography as the reference standard.
Methods: This is a retrospective study of 29 patients with PAD (19 men, 10 women) who underwent lower limb MDCTA (64- or 80-detector) and digital subtraction angiography. Image quality and accuracy of MDCTA for hemodynamically significant stenosis were assessed in the infrarenal aorta and 15 lower extremity segments.
Objective: To investigate the precision and accuracy of a new semi-automated method for kidney segmentation from single-breath-hold non-contrast MRI.
Materials And Methods: The user draws approximate kidney contours on every tenth slice, focusing on separating adjacent organs from the kidney. The program then performs a sequence of fully automatic steps: contour filling, interpolation, non-uniformity correction, sampling of representative parenchyma signal, and 3D binary morphology.
Background And Purpose: Imaging the optic radiation (OR) is of considerable interest in studying diseases affecting the visual pathway and for pre-surgical planning of temporal lobe resections. The purpose of this study was to investigate the clinical feasibility of using probabilistic diffusion tractography based on constrained spherical deconvolution (CSD) to image the optic radiation. It was hypothesized that CSD would provide improved tracking of the OR compared with the widely used ball-and-stick model.
View Article and Find Full Text PDF