Publications by authors named "Jeremiah A Heilman"

Purpose: To evaluate the performance and repeatability assessing liver, spleen, and kidney stiffness with magnetic resonance elastography (MRE), using arrays of pneumatic passive drivers.

Methods: An array of four flexible, pneumatically activated passive drivers for abdominal MRE were developed and tested in this study. Multiple MRE acquisitions were performed prospectively in a series of eleven volunteers, with activation of all combinations of the four drivers, individually and simultaneously.

View Article and Find Full Text PDF

Background: Interest in vertebral body tethering (VBT) as an alternative to posterior spinal fusion for adolescent idiopathic scoliosis (AIS) continues to grow. The purpose of this study was to prospectively assess intervertebral disk health on magnetic resonance imaging (MRI) at 1 year following VBT in AIS patients.

Methods: AIS patients were enrolled in a prospective surgeon-sponsored Food and Drug Administration (FDA) Investigational Device Exemption (IDE) Study and underwent MRI at 1-year following VBT.

View Article and Find Full Text PDF

Purpose: To compare automated versus standard of care manual processing of 2D gradient recalled echo (GRE) liver MR Elastography (MRE) in children and young adults.

Materials And Methods: 2D GRE liver MRE data from research liver MRI examinations performed as part of an autoimmune liver disease registry between March 2017 and March 2020 were analyzed retrospectively. All liver MRE data were acquired at 1.

View Article and Find Full Text PDF

Purpose: Single sideband amplitude modulation (SSB) is an appealing platform for highly parallel wireless MRI detector arrays because the spacing between channels is ideally limited only by the MRI signal bandwidth. However this assumes that no other sources of interference are present outside that bandwidth. This work investigates the practical interference between multiple SSB-encoded MRI signals.

View Article and Find Full Text PDF

A complete high-efficiency transmit amplifier unit designed to be implemented in on-coil transmit arrays is presented. High power capability, low power dissipation, scalability, and cost minimization were some of the requirements imposed to the design. The system is composed of a current mode class-D amplifier output stage and a voltage mode class-D preamplification stage.

View Article and Find Full Text PDF

Multichannel transmission has the potential to improve many aspects of MRI through a new paradigm in excitation. In this study, multichannel transmission is used to address the effects that variations in B(0) homogeneity have on fat-saturation preparation through the use of the frequency, phase, and amplitude degrees of freedom afforded by independent transmission channels. B(1) homogeneity is intrinsically included via use of coil sensitivities in calculations.

View Article and Find Full Text PDF