Publications by authors named "Jered Wells"

Background Diagnostic reference levels (DRLs) and achievable doses (ADs) were developed for the 10 most commonly performed pediatric CT examinations in the United States using the American College of Radiology Dose Index Registry. Purpose To develop robust, current, national DRLs and ADs for the 10 most commonly performed pediatric CT examinations as a function of patient age and size. Materials and Methods Data on 10 pediatric (ie, patients aged 18 years and younger) CT examinations performed between 2016 and 2020 at 1625 facilities were analyzed.

View Article and Find Full Text PDF

Objective: The goal of the study was to determine the potential impact of system inaccuracies and table attenuation on fluoroscope-reported dose values.

Design: An Institutional Review Board-approved study was conducted to collect detailed acquisition and patient exposure data for fluoroscopy-guided lumbar epidural injections.

Background: System-reported dosimetry values, especially the air Kinetic Energy Released per unit MAss and dose-area product metrics, are routinely used for estimating the radiation burden to patients undergoing fluoroscopy-guided procedures.

View Article and Find Full Text PDF

Purpose: The study illustrates how a renewed approach to medical physics, Medical Physics 3.0 (MP3.0), can identify performance decrement of digital radiography (DR) systems when conventional Medical Physics 1.

View Article and Find Full Text PDF

Purpose: The purpose of this study was to determine whether a proposed suite of objective image quality metrics for digital chest radiographs is useful for monitoring image quality in a clinical setting unique from the one where the metrics were developed.

Methods: Seventeen gridless AP chest radiographs from a GE Optima portable digital radiography (DR) unit ("sub-standard" images; Group 2) and 17 digital PA chest radiographs ("standard-of-care" images; Group 1) and 15 gridless (non-routine) PA chest radiographs (images with a gross technical error; Group 3) from a Discovery DR unit were chosen for analysis. Group 2 images were acquired with a lower kVp (100 vs 125) and shorter source-to-image distance (127 cm vs 183 cm) and were expected to have lower quality than Group 1 images.

View Article and Find Full Text PDF

Purpose: The FDA approved the use of digital breast tomosynthesis (DBT) in 2011 as an adjunct to 2D full field digital mammography (FFDM) with the constraint that all DBT acquisitions must be paired with a 2D image to assure adequate interpretative information is provided. Recently manufacturers have developed methods to provide a synthesized 2D image generated from the DBT data with the hope of sparing patients the radiation exposure from the FFDM acquisition. While this much needed alternative effectively reduces the total radiation burden, differences in image quality must also be considered.

View Article and Find Full Text PDF

Purpose: To create a database of highly realistic and anatomically variable 3D virtual breast phantoms based on dedicated breast computed tomography (bCT) data.

Methods: A tissue classification and segmentation algorithm was used to create realistic and detailed 3D computational breast phantoms based on 230 + dedicated bCT datasets from normal human subjects. The breast volume was identified using a coarse three-class fuzzy C-means segmentation algorithm which accounted for and removed motion blur at the breast periphery.

View Article and Find Full Text PDF

Purpose: The most common metrics for resolution analysis in medical imaging are valid only for (approximately) linear systems. While analogues to these metrics have been used in attempts to describe resolution performance in nonlinear systems, the analysis is incomplete since distortion effects are often ignored. The authors have developed a methodology to analyze the amplitude modulation and waveform distortion properties of nonlinear systems with specific application to medical image processing algorithms.

View Article and Find Full Text PDF

Purpose: The modulation transfer function (MTF) of medical imaging devices is commonly reported in the form of orthogonal one-dimensional (1D) measurements made near the vertical and horizontal axes with a slit or edge test device. A more complete description is found by measuring the two-dimensional (2D) MTF. Some 2D test devices have been proposed, but there are some issues associated with their use: (1) they are not generally available; (2) they may require many images; (3) the results may have diminished accuracy; and (4) their implementation may be particularly cumbersome.

View Article and Find Full Text PDF

Purpose: To test the hypothesis that narrowing of cranial blood vessels in cholesterol-fed rabbits is a function of the duration of the high cholesterol diet. Such neurovascular changes, caused by elevated serum cholesterol, are linked to stroke and Alzheimer's disease risk.

Materials And Methods: Four groups of New Zealand White rabbits were studied.

View Article and Find Full Text PDF