Publications by authors named "Jens Herbig"

Discovering the volatile signature of cancer cells is an emerging approach in cancer research, as it may contribute to a fast and simple diagnosis of tumors in vivo and in vitro. One of the main contributors to such a volatile signature is hyperglycolysis, which characterizes the cancerous cell. The metabolic perturbation in cancer cells is known as the Warburg effect; glycolysis is preferred over oxidative phosphorylation (OXPHOS), even in the presence of oxygen.

View Article and Find Full Text PDF

Cancer cells prefer hyperglycolysis versus oxidative phosphorylation, even in the presence of oxygen. This phenomenon is used through the FDG-PET scans, and may affect the exhaled volatile signature. This study investigates the volatile signature in lung cancer (LC) before and after an oral glucose tolerance test (OGTT) to determine if tumor cells' hyperglycolysis would affect the volatile signature.

View Article and Find Full Text PDF

Proton transfer reaction mass spectrometry (PTR-MS) is a well-established technique for real-time analysis of volatile organic compounds (VOCs). Although it is extremely sensitive (with sensitivities of up to 4500 cps/ppbv, limits of detection <1 pptv and the response times of approximately 100 ms), the selectivity of PTR-MS is still somewhat limited, as isomers cannot be separated. Recently, selectivity-enhancing measures, such as manipulation of drift tube parameters (reduced electric field strength) and using primary ions other than H3O(+), such as NO(+) and O2 (+), have been introduced.

View Article and Find Full Text PDF

Despite growing interest and considerable progress in breath research over the last decade, standardized practices for the sampling and analysis of breath gas volatiles remain elusive. The primary reasons for this are (a) the rich chemical diversity of exhaled breath that covers an extensive range of volatile organic compounds at highly varied concentrations, (b) the vast disparity in the analytical tools employed, (c) diverse study goals and (d) the presence of (unidentified) confounders. These aspects place stringent but divergent demands on sampling and analysis: each analytical tool, target compound and concentration range requires its own specific protocol and in many cases the latter two are not even known a priori.

View Article and Find Full Text PDF

Breath analysis research is being successfully pursued using a variety of analytical methods, prominent amongst which are gas chromatography with mass spectrometry, GC-MS, ion mobility spectrometry, IMS, and the fast flow and flow-drift tube techniques called selected ion flow tube mass spectrometry, SIFT-MS, and proton transfer reaction mass spectrometry, PTR-MS. In this paper the case is made for real-time breath analysis by obviating sample collection into bags or onto traps that can suffer from partial degradation of breath metabolites or the introduction of impurities. Real-time analysis of a broad range of volatile chemical compounds can be best achieved using SIFT-MS and PTR-MS, which are sufficiently sensitive and rapid to allow the simultaneous analyses of several trace gas metabolites in single breath exhalations.

View Article and Find Full Text PDF

Proton-transfer-reaction time-of-flight mass-spectrometry (PTR-TOFMS) exhibits high selectivity with a resolution of around 5000 m/Δm. While isobars can be separated with this resolution, discrimination of isomeric compounds is usually not possible. The coupling of a multi-capillary column (MCC) with a PTR-TOFMS overcomes these problems as demonstrated in this paper for the ketone isomers 3-heptanone and 2-methyl-3-hexanone and for different aldehydes.

View Article and Find Full Text PDF

We analysed the time evolution of several volatile organic compounds formed by the catabolism of ingested isotope-labelled ethanol using real-time breath gas analysis with proton-transfer-reaction mass spectrometry. Isotope labelling allowed distinguishing the emerging volatile metabolites from their naturally occurring, highly abundant counterparts in the human breath. Due to an extremely low detection limit of the employed technologies in the parts per trillion per volume range, it was possible to detect the emerging metabolic products in exhaled breath within ∼10 min after oral ingestion of isotope-labelled ethanol.

View Article and Find Full Text PDF

We report on the search for low molecular weight molecules-possibly accumulated in the bloodstream and body-in the exhaled breath of uremic patients with kidney malfunction. We performed non-invasive analysis of the breath gas of 96 patients shortly before and several times after kidney transplantation using proton-transfer-reaction mass spectrometry (PTR-MS), a very sensitive technique for detecting trace amounts of volatile organic compounds. A total of 642 individual breath analyses which included at least 41 different chemical components were carried out.

View Article and Find Full Text PDF

Most--if not all--potential diagnostic applications in breath research involve different marker concentrations rather than unique breath markers which only occur in the diseased state. Hence, data interpretation is a crucial step in breath analysis. To avoid artificial significance in breath testing every effort should be made to implement method validation, data cross-testing and statistical validation along this process.

View Article and Find Full Text PDF

We report on the implementation of proton transfer reaction-mass spectrometry (PTR-MS) technology for on-line monitoring of volatile organic compounds (VOCs) in the off-gas of bioreactors. The main part of the work was focused on the development of an interface between the bioreactor and an analyzer suitable for continuous sampling of VOCs emanating from the bioprocess. The permanently heated sampling line with an inert surface avoids condensation and interaction of volatiles during transfer to the PTR-MS.

View Article and Find Full Text PDF

We report on on-line breath gas analysis with a new type of analytical instrument, which represents the next generation of proton-transfer-reaction mass spectrometers. This time-of-flight mass spectrometer in combination with the soft proton-transfer-reaction ionization (PTR-TOF) offers numerous advantages for the sensitive detection of volatile organic compounds and overcomes several limitations. First, a time-of-flight instrument allows for a measurement of a complete mass spectrum within a fraction of a second.

View Article and Find Full Text PDF

Gathering information about a subject's physiological and pathophysiological condition from the `smell' of breath is an idea that dates back to antiquity. This intriguing concept of non-invasive diagnosis has been revitalized by `exhaled breath analysis' in recent decades. A main driving force was the development of sensitive and versatile gas-chromatographic and mass-spectrometric instruments for trace gas analysis.

View Article and Find Full Text PDF

The storage capability of Tedlar® bags for gaseous compounds was assessed using on-line proton-transfer-reaction mass spectrometry (PTR-MS). Sample bags were filled with a mixture of volatile organic compounds (VOCs) at known quantities in the ppbv range. The test gas included alcohol, nitrile, aldehyde, ketone, terpene and aromatic compounds.

View Article and Find Full Text PDF

We present a novel method for real-time breath-gas analysis using mass-spectrometric techniques: buffered end-tidal (BET) on-line sampling. BET has several advantages over conventional direct on-line sampling where the subject inhales and exhales through a sampling tube. In our approach, a single exhalation is administered through a tailored tube in which the end-tidal fraction of the breath-gas sample is buffered.

View Article and Find Full Text PDF

We study three-body recombination in an optically trapped ultracold gas of cesium atoms with precise magnetic control of the s-wave scattering length a. At large positive values of a, we measure the dependence of the rate coefficient on a and confirm the theoretically predicted scaling proportional to a(4). Evidence of recombination heating indicates the formation of very weakly bound molecules in the last bound energy level.

View Article and Find Full Text PDF

An ultracold molecular quantum gas is created by application of a magnetic field sweep across a Feshbach resonance to a Bose-Einstein condensate of cesium atoms. The ability to separate the molecules from the atoms permits direct imaging of the pure molecular sample. Magnetic levitation enables study of the dynamics of the ensemble on extended time scales.

View Article and Find Full Text PDF

Bose-Einstein condensation of cesium atoms is achieved by evaporative cooling using optical trapping techniques. The ability to tune the interactions between the ultracold atoms by an external magnetic field is crucial to obtain the condensate and offers intriguing features for potential applications. We explore various regimes of condensate self-interaction (attractive, repulsive, and null interaction strength) and demonstrate properties of imploding, exploding, and non-interacting quantum matter.

View Article and Find Full Text PDF