In this paper, we introduce a compact, single-sided stray field sensor for NMR relaxometry applications. The sensor consists of four main components: the magnet, the RF coil, the spectrometer, and the translation stage. Our proposed magnet, an improved design of the Profile NMR-MOUSE, is designed for low weight, compactness, and magnetic field homogeneity, achieved through various shim strategies using a mixed genetic algorithm.
View Article and Find Full Text PDFDNP-NMR and EPR experiments that operate at or greater than L-band (i.e., ν(e) = 1-2 GHz) are typically limited to maximum sample volumes of several hundred µL.
View Article and Find Full Text PDFElectron paramagnetic resonance (EPR) spectroscopy provides information about the physical and chemical properties of materials by detecting paramagnetic states. Conventional EPR measurements are performed in high resonator using large electromagnets which limits the available space for operando experiments. Here we present a solution toward a portable EPR sensor based on the combination of the EPR-on-a-Chip (EPRoC) and a single-sided permanent magnet.
View Article and Find Full Text PDFElectron paramagnetic resonance-on-a-chip (EPRoC) devices use small voltage-controlled oscillators (VCOs) for both the excitation and detection of the EPR signal, allowing access to unique sample environments by lifting the restrictions imposed by resonator-based EPR techniques. EPRoC devices have been successfully used at multiple frequencies (7 to 360 gigahertz) and have demonstrated their utility in producing high-resolution spectra in a variety of spin centers. To enable quantitative measurements using EPRoC devices, the spatial distribution of the field produced by the VCOs must be known.
View Article and Find Full Text PDFThe excellent versatility of 5-axis computer numerical control (CNC) micromilling has led to its application for prototyping NMR microcoils tailored to mass-limited samples (reducing development time and cost). However, vibrations during 5-axis milling can hinder the creation of complex 3D volume microcoils (i.e.
View Article and Find Full Text PDFIn this paper, we present a chip-based C-band ODNP platform centered around an NMR-on-a-chip transceiver and a printed microwave (MW) Alderman-Grant (AG) coil with a broadband tunable frequency range of 528MHz. The printable ODNP probe is optimized for a high input-power-to-magnetic-field conversion-efficiency, achieving a measured ODNP enhancement factor of -151 at microwave power levels of 33.3dBm corresponding to 2.
View Article and Find Full Text PDFBoth surgeons and patients want to achieve a high level of satisfaction and the best possible functional results within a short time after knee TEP surgery. By using a tool that digitally records various measurement parameters of balance and motor function preoperatively and postoperatively on a mobile basis and with little time expenditure, progressive results can be compared. Individual factors can thus be determined and these can influence the progress in regeneration and training progress perioperatively.
View Article and Find Full Text PDFIn environmental research, it is critical to understand how toxins impact invertebrate eggs and egg banks, which, due to their tiny size, are very challenging to study by conventional nuclear magnetic resonance (NMR) spectroscopy. Microcoil technology has been extensively utilized to enhance the mass-sensitivity of NMR. In a previous study, 5-axis computer numerical control (CNC) micromilling (shown to be a viable alternative to traditional microcoil production methods) was used to create a prototype copper slotted-tube resonator (STR).
View Article and Find Full Text PDFIEEE Trans Biomed Circuits Syst
February 2024
Electrophysiological (EP) mapping catheters are medical equipment, which are widely used to diagnose and treat atrial fibrillation. The electrophysiology signals are sensed by the catheter's electrodes, for which a large electrode count becomes more and more essential because of the demand for a higher local resolution. A drawback of the large electrode count is the effort to pass through and to integrate the wires inside the catheter shaft.
View Article and Find Full Text PDFPurpose: Both dynamic intraligamentary stabilization (DIS) and reconstruction (RECO) are common treatment methods for anterior cruciate ligament (ACL) rupture. We report short term outcomes after DIS (Ligamys, Mathys, Bettlach, Switzerland) and RECO using semitendinosus tendon. We compared postoperative complications, deficits of range-of-motion (ROM), and revision rates between the two treatment options.
View Article and Find Full Text PDFIEEE Trans Biomed Circuits Syst
August 2023
In this article, we present a portable NMR relaxometry system optimized for the point-of-care analysis of body liquids such as blood. The presented system is centered on an NMR-on-a-chip transceiver ASIC, a reference frequency generator with arbitrary phase control, and a custom-designed miniaturized NMR magnet with a field strength of 0.29 T and a total weight of 330 g.
View Article and Find Full Text PDFIn this paper, we present a custom-designed nuclear magnetic resonance (NMR) platform based on a broadband complementary metal-oxide-semiconductor (CMOS) NMR-on-a-chip transceiver and a synchronous reference signal generator, which features arbitrary phase control of the excitation pulse in combination with phase-coherent detection at a non-zero intermediate frequency (IF). Moreover, the presented direct digital synthesis (DDS)-based frequency generator enables a digital temperature compensation scheme similar to classical field locking without the need for additional hardware. NMR spectroscopy and relaxometry measurements verify the functionality of the proposed frequency reference and temperature compensation scheme as well as the overall state-of-the-art performance of the presented system.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
November 2021
This paper describes a realization of an electrophysiology (EP) catheter with 96 electrodes which requires no electrical wiring to the outside by relying on an optical link for both power supply and data communication. The catheter tip is constructed from a liquid crystal polymer (LCP) material. It features 96 gold electrodes, which are uniformly arranged along an expandable basket.
View Article and Find Full Text PDFNanocharacterization plays a vital role in understanding the complex nanoscale organization of cells and organelles. Understanding cellular function requires high-resolution information about how the cellular structures evolve over time. A number of techniques exist to resolve static nanoscale structure of cells in great detail (super-resolution optical microscopy, EM, AFM).
View Article and Find Full Text PDFIn this paper, we present an in-depth analysis of a voltage-controlled oscillator (VCO)-based sensing method for electron spin resonance (ESR) spectroscopy, which greatly simplifies the experimental setup compared to conventional detection schemes. In contrast to our previous oscillator-based ESR detectors, where the ESR signal was encoded in the oscillation frequency, in the amplitude-sensitive method, the ESR signal is sensed as a change of the oscillation amplitude of the VCO. Therefore, using VCO architecture with a built-in amplitude demodulation scheme, the experimental setup reduces to a single permanent magnet in combination with a few inexpensive electronic components.
View Article and Find Full Text PDFElectron paramagnetic resonance (EPR) spectroscopy is the method of choice to investigate and quantify paramagnetic species in many scientific fields, including materials science and the life sciences. Common EPR spectrometers use electromagnets and microwave (MW) resonators, limiting their application to dedicated lab environments. Here, novel aspects of voltage-controlled oscillator (VCO)-based EPR-on-a-Chip (EPRoC) detectors are discussed, which have recently gained interest in the EPR community.
View Article and Find Full Text PDFChange is inherent to time being transient. With the NMR-MOUSE (MObile Universal Surface Explorer) having matured into an established NMR tool for nondestructive testing of materials, this forward-looking retrospective assesses the challenges the NMR-MOUSE faced when deployed outside a protected laboratory and how its performance quality can be maintained and improved when operated under adverse conditions in foreign environments. This work is dedicated to my dear colleague and friend Geoffrey Bodenhausen on the occasion of his crossing an honorable timeline in appreciation of his ever-continuing success of fueling the dynamics of magnetic resonance.
View Article and Find Full Text PDFIn this paper, we introduce 3D printing as a possibility for realizing lightweight, yet high-precision NMR magnets. Using a commercially available filament containing steel particles allows for the realization of critical components of NMR magnets such as pole pieces and even the flux-conducting yoke. In contrast to shimming structures made of iron, 3D printed structures made of the lightweight filament allow for a robust and inexpensive way of realizing high-performance NMR magnets for future portable NMR applications.
View Article and Find Full Text PDFIn this paper, we review the latest developments in miniaturization of NMR systems with an emphasis on low-field NMR. We briefly cover the topics of magnet and coil miniaturization, elaborating on the advantages and disadvantages of miniaturized coils for different applications. The main part of the article is dedicated to progress in NMR electronics.
View Article and Find Full Text PDFPurpose: In spite of consistent improvement in operative methods for total knee arthroplasty, individual motor deficits may lead to a lower outcome. The preoperative classification in individual motoric capacity may get more significance for the future. Complementary to established questionnaires and clinical tests, this pilot study should demonstrate that it is possible to generate a preoperative motor score using a force platform measurement (KMP).
View Article and Find Full Text PDFPurpose: Up to 20% of total knee arthroplasty (TKA) patients remain dissatisfied, with chronic pain as the most frequently named cause. A pilot study was conducted to assess the progression of peri-operative pain intensity and the parallel development of different psychological factors and coping strategies, as well as correlations indicating potential inter-relationships.
Methods: Pain, psychological impairment [FESV BE], and coping strategies [FESV BW] were assessed before and after TKA [days - 5 to 31].
Magnetic resonance imaging and spectroscopy are versatile methods for probing brain physiology, but their intrinsically low sensitivity limits the achievable spatial and temporal resolution. Here, we introduce a monolithically integrated NMR-on-a-chip needle that combines an ultra-sensitive 300 µm NMR coil with a complete NMR transceiver, enabling in vivo measurements of blood oxygenation and flow in nanoliter volumes at a sampling rate of 200 Hz.
View Article and Find Full Text PDFUltrashort echo time imaging on clinical systems is still limited by the rather long radio frequency switching times achievable with standard front end concepts. In this contribution, an independent parallel receive-only system is interfaced to an unmodified clinical MRI system, enabling imaging of species with ultrashort relaxation times, such as bone, tendon, teeth, or lung tissue. Synchronization of the system is achieved by an electronically decoupled one-way trigger line, a clock reference signal, and RF pulse tracking, thus ensuring minimal interference with the host system.
View Article and Find Full Text PDF