Publications by authors named "Jenny E Zablah"

The Catheterization RISk Score for Pediatrics (CRISP) has been validated and widely adopted as a model to predict adverse outcomes. We sought to determine if the addition of three modifiers (NYHA Class > 2, prior sternotomies > 2, and BMI > 30) to the CRISP score would better predict adverse events (AE) in adults undergoing cardiac catheterization at our institution. All adults (> 18 years) who underwent cardiac catheterization at the Children's Hospital Colorado from November 2016 to November 2021 were included.

View Article and Find Full Text PDF

We present the case of 53-year-old woman with a late diagnosis of an right pulmonary artery-left atrium fistula who underwent transcatheter device closure using multi-modality imaging for pre-procedural planning and procedural guidance.

View Article and Find Full Text PDF

The management of superior sinus venosus defects (SVD) via transcatheter covered stent (CS) placement is becoming an acceptable alternative to open heart surgery. Though the medium-term success of this procedure has been described, residual shunting from damage to the covering of the implanted stents, use of stents which are too short and unanticipated shortening of stents may result in immediate or short-term procedural failure. In such cases, placement of a second CS may be required to address a residual defect.

View Article and Find Full Text PDF
Article Synopsis
  • Virtual reality technology allows for detailed 3D visualizations of complex heart anatomy using cross-sectional imaging, enhancing understanding of cardiac conditions.
  • It plays a key role in planning and simulating complex congenital heart procedures, which is essential for successful interventions.
  • The case series highlights the effectiveness of virtual reality in facilitating remote consultations among institutions using CT angiography before performing congenital percutaneous interventions.
View Article and Find Full Text PDF

Background: Accurate assessment of the pulmonary valve can dictate clinical management of patients with right ventricular outflow tract (RVOT) anomalies. Comparisons with available normal reference values are essential for accurate evaluation. The aim of the study was to generate normative data for the pulmonary valve annulus and sino-tubular (ST) junction using CT measurements derived from a heterogeneous pediatric population and create z-scores useful for clinical practice.

View Article and Find Full Text PDF
Article Synopsis
  • Patients with d-transposition of the great arteries (d-TGA) who have had an arterial switch operation (ASO) may experience right ventricular outflow tract (RVOT) issues, leading to the consideration of transcatheter pulmonary valve replacement (TPVR) as a treatment option.
  • A study involving 33 patients showed a 66% success rate for TPVR, with most patients receiving either a Melody or SAPIEN valve, while some conditions like coronary compression prevented the procedure for a subset of patients.
  • Post-TPVR, there was a significant reduction in RVOT gradient and a majority of patients reported minimal or no pulmonary regurgitation; however, a higher rate of reinterventions was noted in this
View Article and Find Full Text PDF

Obstructed infracardiac total anomalous pulmonary venous return is nearly always a surgical emergency in which infants present in severe cardiopulmonary distress. Ductal venosus stenting can provide a temporizing option for premature, low birth weight infants with high risk for surgical complications. In challenging anatomic cases, virtual reality, 3D-printed models, and fusion image guidance can aid in procedural planning and provide support for successful intervention.

View Article and Find Full Text PDF

Wearable biosensors (wearables) enable continual, noninvasive physiologic and behavioral monitoring at home for those with pediatric or congenital heart disease. Wearables allow patients to access their personal data and monitor their health. Despite substantial technologic advances in recent years, issues with hardware design, data analysis, and integration into the clinical workflow prevent wearables from reaching their potential in high-risk congenital heart disease populations.

View Article and Find Full Text PDF

Recent advances in available percutaneous device technology require accurate measurements and quantification of relationships between right ventricular outflow tract (RVOT) structures in children with and without congenital heart disease to determine device suitability. To date, no population study has described normal reference ranges of these measurements by computed tomography (CT). We aimed to establish normative values for four CT-derived measurements between RVOT structures from a heterogeneous population without heart disease and develop z scores useful for clinical practice.

View Article and Find Full Text PDF

For congenital heart disease patients, multiple imaging modalities are needed to discern anatomy and functional information such as differential blood flow. During cardiac catheterization, 3D rotational angiography (3DRA) can provide CTA-like images, enabling anatomical information and intraprocedural guidance. We seek to establish whether unique aspects of this technique can also generate quantitative functional blood flow information.

View Article and Find Full Text PDF

Background: In recent years, self-expanding technology to treat pulmonary regurgitation in the native right ventricular outflow tract became Food and Drug Administration approved in the United States and is now routinely used. The current practice for selection of patients who are candidates for these devices includes screening for "anatomic fit," performed by each of the manufacturing companies. Our study aims to validate the use of virtual reality (VR) as a tool for local physician-led screening of patients.

View Article and Find Full Text PDF

Hereditary haemorrhagic telangiectasia is an inherited disorder characterised by vascular dysplasia that leads to the development of arteriovenous malformations. Pulmonary arteriovenous malformations occur in approximately 30% of patients with haemorrhagic telangiectasia. Given the complex characteristics of haemorrhagic telangiectasia lesions, the application of three-dimensional fusion imaging holds significant promise for procedural guidance and decrease in contrast and radiation dosing.

View Article and Find Full Text PDF

Three-dimensional intracardiac echocardiography (3D ICE) has gained popularity in interventional cardiology given its improved spatial and temporal imaging in assessing intracardiac anatomy pre- and post-intervention. We describe the use of 3D ICE in the reduction of a Fontan fenestration with an Occlutech atrial flow regulator (AFR) device.

View Article and Find Full Text PDF

Transcatheter pulmonary valve replacement (TPVR) is commonly performed in patients with congenital heart disease as a safe alternative to replacement via open heart surgery. Intracardiac echocardiography (ICE) is a useful technique for evaluating multiple structures that are difficult to assess by other echocardiographic techniques, particularly the pulmonary valve. To our knowledge, the use of three-dimensional (3D) ICE catheters to evaluate prosthetic valves after TPVR has not been reported.

View Article and Find Full Text PDF

VA-ECMO can be lifesaving in cardiogenic shock in children. While surgical vascular repair is the current standard of care for decannulation, it comes with notable risks. We present a series of eight patients who underwent decannulation with a collagen plug-based vascular closure device (MANTA) for the common femoral artery.

View Article and Find Full Text PDF

We describe serial implantation of atrial flow regulator (AFR) devices in the Fontan fenestration of a 4-year-old patient. Initially, the fenestration size was decreased using a 6/5 AFR, resulting in improved saturations and hemodynamics. One year later, further improvement was achieved by placing a 4/10 AFR inside the original device.

View Article and Find Full Text PDF

Background: Developmental pulmonary vein pulmonary vein stenosis in the setting of prematurity is a rare and poorly understood condition. Diagnosis can be challenging in the setting of chronic lung disease of prematurity. High-resolution non-contrast chest computed tomography (CT) is the conventional method of evaluating neonates for potential structural changes contributing to severe lung dysfunction and pulmonary hypertension but may miss pulmonary venous stenosis due to the absence of contrast and potential overlap in findings between developmental pulmonary vein pulmonary vein stenosis and lung disease of prematurity.

View Article and Find Full Text PDF

A 53-day-old girl with absent right atrioventricular (AV) connection, malposed great vessels, and pulmonary atresia underwent placement of a central shunt on the sixth day of her life. Her postoperative course was complicated by progressive desaturation, and computed tomographic angiography (CTA) demonstrated near-complete occlusion of her left pulmonary artery (LPA). Angiography demonstrated a nonocclusive thrombus in the distal central shunt and a thrombus with complete occlusion of the LPA.

View Article and Find Full Text PDF

Background: Pulmonary vein stenosis (PVS) is a growing problem for the pediatric congenital heart population. Sirolimus has previously been shown to improve survival and slow down the progression of in-stent stenosis in patients with PVS. We evaluated patients before and after initiation of sirolimus to evaluate its effects on re-intervention and vessel patency utilizing Optical Coherence Tomography (OCT).

View Article and Find Full Text PDF

Evaluate the use of coronary CTA as an initial assessment for determining Right Ventricle Dependent Coronary Circulation (RVDCC) in neonates with Pulmonary Atresia with Intact Ventricular Septum (PA IVS). Retrospective review of cases with coronary CTA and compare with available catheter angiography, pathology, surgical reports, and outcomes from Mar 2015 to May 2022. In our cohort of 16 patients, 3 were positive for RVDCC, confirmed by pathologic evaluation, and there was concordance for presence or absence of RVDCC with catheter angiography in 5 patients (4 negatives for RVDCC, 1 positive).

View Article and Find Full Text PDF

Objectives: We report our experience in simultaneously implanting multiple stents and valves mounted on a single balloon before and during transcatheter pulmonary valve placement.

Background: Heterogeneity and complexity of the right ventricular outflow tract (RVOT) may complicate stent deployment when preparing a landing zone for transcatheter pulmonary valve implantation.

Methods: Retrospective analysis of patients from Children's Hospital of Colorado, USA; and Oslo University Hospital, Norway, undergoing transcatheter pulmonary valve replacement that had at least two stents mounted on a single balloon, deployed in the RVOT.

View Article and Find Full Text PDF

A 25-year-old male presented to our institution with acute right ventricular (RV) failure secondary to an infected pulmonary prosthetic valve (Melody® Valve, Medtronic Inc., Minneapolis, MN, USA), 3 months after percutaneous placement. Due to his decompensated state, his surgical risk was determined to be very high during his acute illness.

View Article and Find Full Text PDF